arXiv:2610.28693cs.LGOct 2026

Manuscript Offprint

arXiv:2610.28693

Interaction-Gated Time-Frequency Learning for Parameter-Efficient PPG-Based Heart Rate Estimation

Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Anh Khoi Pham 1^{1}[0009-0005-9381-4867], Phat Lam 2^{2}[0009-0003-5105-5976], Thien Truong Nguyen Ly 3^{3}[0000-0002-7422-4600], and Lam Pham 4^{4}[0000-0001-8155-7553]★

1^{1} International University, Vietnam National University HCMC, Ho Chi Minh City, Vietnam

2^{2} University of New Brunswick, Fredericton, Canada

3^{3} Ho Chi Minh City University of Technology, Ho Chi Minh City, Vietnam

4^{4} Austrian Institute of Technology, Vienna, Austria

Abstract. Photoplethysmography (PPG) enables low-cost and non-invasive heart rate (HR) monitoring but remains sensitive to waveform distortion, physiological variability, and measurement interference. Temporal waveform characteristics and frequency-domain periodicity provide complementary information for HR estimation; however, effectively exploring and integrating these representations within a compact model remains challenging. This paper proposes TF-IG, a parameter-efficient interaction-gated time-frequency learning framework for PPG-based HR estimation. TF-IG employs a dual-branch architecture in which a temporal branch captures pulse morphology via dilated depthwise-separable convolutions, while a frequency branch extracts cardiac periodicity information from bounded log-spectrogram representations. To combine the two domains, we introduce an interaction-gated fusion module that explicitly models feature agreement and discrepancy, while also learning feature-wise weights to balance temporal and spectral information. A parameter-shared regression head further maps the temporal, spectral, and fused representations into the final HR prediction space. Experiments on the benchmark BIDMC PPG and Respiration Dataset using a subject-exclusive training, validation, and test protocol show that TF-IG achieves an MAE of 1.227 BPM, a RMSE of 2.060 BPM, Pearson correlation of 0.9934, and 92.28% of estimates within 3 BPM, while remaining parameter-efficient with only 84.6K parameters. Ablation results further demonstrate the complementary contributions of the temporal and frequency branches, interaction-gated fusion, and shared regression head. These results indicate that explicitly modeling cross-domain interactions provides an effective accuracy–complexity trade-off for lightweight PPG-based HR estimation.

Keywords— PPG, HR Estimation, BIDMC PPG, Time-Frequency, Feature interaction.

1 Introduction

Continuous heart-rate (HR) monitoring plays an important role in clinical observation, fitness assessment, ambulatory healthcare and long-term physiological monitoring [13], [1]. Although electrocardiography (ECG) remains a standard reference for

  • Corresponding author

A. K. Pham et al

cardiac monitoring, photoplethysmography (PPG) provides an attractive alternative for continuous and wearable sensing because it measures peripheral blood-volume variations using inexpensive and non-invasive optical hardware [2], [9]. Its compact sensing configuration has consequently enabled widespread integration into wearable devices, pulse oximeters, smartphones, and other resource-constrained monitoring platforms. PPG therefore represents a practical sensing modality for scalable and continuous cardiovascular monitoring [2], [1]. Despite these advantages, reliable HR estimation from PPG remains challenging. The measured waveform is influenced not only by cardiac pulsation but also by physiological and acquisition-related factors such as respiration, body site, tissue characteristics, ambient illumination, applied pressure, and artifacts [4].

A broad range of signal-processing and learning-based approaches has therefore been developed for PPG-based HR estimation. Classical methods typically rely on filtering, peak detection, spectral analysis, or handcrafted signal descriptors [12], [6]. More recently, deep learning has enabled HR-relevant features to be learned directly from PPG observations rather than relying entirely on manually designed processing rules. For example, PPGNet [17] proposed an end-to-end network operating directly on short PPG segments for device-independent HR estimation; Deep PPG [15] leverages convolutional neural networks over spectrogram of PPG and accelerometer signals; Ismail et al. [7] further explored a set of features characterizing the signal, modeling by a convolutional-recurrent framework, etc. These studies demonstrate that temporal and spectral representations of PPG can provide useful information for HR estimation.

The complementarity of temporal and spectral domain follows naturally from the characteristics of PPG. The temporal domain preserves local pulse morphology and short-term waveform dynamics, whereas the frequency domain makes periodic cardiac activity more explicit. Time-frequency representations further characterize how this spectral structure evolves over the observation interval, emphasizing different aspects of the same underlying physiological process [7]. Although prior work has demonstrated the utility of signal, spectral, and time-frequency representations, effectively structuring the interaction between complementary representations remains an important design problem. The availability of multiple representations does not by itself determine how they should be combined [5]. Under signal variability or corruption, temporal and spectral features may provide partly consistent yet partly different evidence about the underlying HR. Therefore, an effective fusion mechanism should explicitly characterize where they agree, where they differ, and how strongly each should jointly contribute to the final representation.

Motivated by these observations, we propose TF-IG, a parameter-efficient Interaction-Gated Time–Frequency learning framework for PPG-based HR estimation. First, TF-IG learns complementary HR representations through two lightweight branches: a temporal branch based on dilated depthwise-separable convolutions and temporal attention pooling, and a frequency branch that processes a bounded log-spectrogram using spectrotemporal attention pooling. Second, these representations are integrated through a structured interaction-gated mechanism. Element-wise multiplication and absolute difference explicitly encode cross-domain co-activation and discrepancy, while a feature-wise gate adaptively balances the temporal and spectral embeddings. The resulting fused representation, together with the individual branch embeddings, is processed by a shared regression head that provides a common mapping to HR, with the three predictions subsequently combined through learned normalized weights. In this way, TF-IG jointly addresses complementary representation learning, explicit cross-domain interaction, and parameter-efficient prediction within a unified lightweight framework. Accordingly, the main contributions of this work are summarized as follows:

– Compact dual-domain representation learning. We propose a parameter-efficient dual-branch architecture that jointly captures temporal pulse morphology and spectrotemporal cardiac periodicity using dilated depthwise-separable convolutions and attention-based pooling.

– Structured cross-domain fusion and shared prediction. We introduce an interaction-gated fusion mechanism that explicitly models temporal–spectral co-activation and discrepancy through element-wise multiplication and absolute difference, while a feature-wise gate adaptively balances the contribution of the two domains. A parameter-shared regression head is further applied to the temporal, frequency, and fused embeddings, providing a common space for HR prediction mapping while avoiding separate prediction networks.

– Empirical validation of the proposed design. On a subject-independent BIDMC split, TF-IG achieves an MAE of 1.227 BPM, an RMSE of 2.060 BPM, a Pearson correlation of 0.9934, and a CP3CP_{3} of 92.28% using only 84.6K parameters. Ablation experiments further demonstrate the complementary contributions of dual-domain representation learning, interaction-gated fusion, and shared regression to the final performance.