Abstract

True whole-body medical imaging captures a patient from head to toe and provides comprehensive anatomical and/or functional information. This coverage enables reconstruction of the external body surface, yielding patient body models. However, scanner geometry (e.g., bore diameter), patient characteristics, and positioning can leave body regions missing (e.g., lateral arms/torso, hands, forearms, elbows), producing incomplete patient body models. Such incompleteness limits downstream medical analyses, including derivation of body-habitus metrics (BHMs), such as body volume and surface area, for injected radiotracer activity regimens, cardiometabolic risk assessment, and computational anatomical modeling for medical imaging simulation and radiation dosimetry. We present the Medical Body model Optimization-based Estimator (MedBOE), an automated, training-free framework for estimating complete patient body models from whole-body images with missing body regions. Our innovation is to leverage the Skinned Multi-Person Linear (SMPL) template, a parametric body mesh representing a broad range of body shapes and poses, in medical imaging. MedBOE aligns the SMPL template to the incomplete patient body models via attribute-guided optimization and estimates missing body regions.

through geometrically and volumetrically constrained deformation. We evaluated MedBOE using two public datasets: AutoPET (91 whole-body PET-CT images) and Human Implicit Tissues (HIT; 40 whole-body segmentations from MRI images). MedBOE achieved the best overall volumetric and geometric performance among evaluated methods. BHMs derived from MedBOE were within 2% error, suggesting low percentage errors for downstream analyses. MedBOE offers an automated, training-free method for estimating complete patient body models from whole-body images with missing body regions.

Keywords: Patient body surface model, Complete body model estimation, Whole-body medical imaging, Body-habitus metrics, Missing body region

1 Introduction

Medical imaging is indispensable to current healthcare and is used for diagnosis, treatment planning, intervention, and treatment monitoring [1]. Imaging modalities, including computed tomography (CT), magnetic resonance imaging (MRI), and multimodal positron emission tomography (PET)-CT, can provide three-dimensional (3D) anatomical and/or functional information. Recent PET-CT systems with extended axial coverage enable true whole-body imaging from head to toe [2].

Whole-body imaging enables comprehensive reconstruction of the patient’s external body surface, producing patient body models that can be visualized, manipulated, and analyzed for clinical applications. These applications include surgical navigation, where the body model is aligned with the patient’s physical body using surface landmarks to enable on-body visualization of internal structures in conjunction with the model [3]. It also enables the derivation of body-habitus metrics (BHMs), including body surface area, body volume, and regional circumferences [4], for optimizing injected radiotracer activity regimens [5], cardiometabolic risk assessment [6], and computational anthropomorphic anatomical models used in medical imaging simulation and radiation dosimetry [7].

However, whole-body imaging (Fig. 1(a)) often fails to fully capture certain body regions, including lateral arms, parts of the torso, hands, forearms, and lower limbs, primarily due to limited transverse field-of-view (FoV) imposed by the scanner gantry diameter and scanning protocol, insufficient axial coverage, patient body size, and patient positioning [8, 9]. Such omissions produce incomplete patient body models (Fig. 1(b)), reducing their utility for downstream applications requiring accurate BHMs [5, 6].

In the multimedia domain, methods for estimating complete body models from incomplete inputs (e.g., partial meshes or point clouds) have been actively developed to create, for example, “virtual humans” for animation and motion capture [10–17]. For human body reconstruction, these methods are commonly developed and evaluated using non-clinical data depicting upright subjects (e.g., standing or sitting), with incomplete observations arising from occlusion or partial surface capture. In contrast, medical imaging commonly involves supine positioning (lying back) and incomplete

(i)

Figure

(a) Whole-body image

(b) Reconstructed incomplete patient body model

(ii)

(c) Fitted SMPL mesh

(iii)

(d) Initial complete patient body model

(e) Final complete patient body model

Fig. 1 Overview of the proposed MedBOE. A whole-body image with missing forearms, elbows, and hands (a) is processed through MedBOE's three modules: (i) Body model reconstruction; (ii) Global parametric fitting; (iii) Missing Body Region Estimation and Surface Deformation, yielding outputs (b)–(e). The patient's face is blurred for anonymization

coverage, with some regions (e.g., hands and forearms) entirely excluded from the scan. Additionally, supervised completion methods typically rely on large training datasets of paired complete and incomplete models [13], which are not publicly available in medical imaging. Despite these advances in multimedia-based body reconstruction, differences in pose, body coverage, training data, and reconstruction objectives limit their direct applicability to clinical settings. This discrepancy highlights a critical gap between multimedia and medical imaging domains, motivating the need to examine how related challenges have been addressed within medical imaging research and to identify remaining limitations.

In the medical application domain, prior studies address related but distinct problems. Medical-imaging studies that compensate for missing information on a slice-wise or image-volume basis [8, 9, 18] can recover missing image information for image correction, attenuation correction, and field-of-view extension. However, these truncation-compensation methods focus on recovering missing information in the image, sinogram, or attenuation-map domain, rather than estimating a continuous complete external body model. Other studies have leveraged the Skinned Multi-Person Linear (SMPL) template mesh [19], a parametric complete human body model, in medical imaging to estimate body composition and internal anatomical structures from external body surfaces [20, 21]. These studies typically rely on complete body coverage acquired using specialized imaging protocols or semi-automatic external-surface fitting procedures that are difficult to scale. More importantly, their primary aim was not to estimate complete patient body models from routine whole-body medical images with missing body regions. In our literature review, no prior work has addressed complete body model estimation from whole-body medical images with missing body regions.

The objective of this study was to develop and evaluate the Medical Body model Optimization-based Estimator (MedBOE), a fully automated, training-free framework for estimating complete patient body models from whole-body medical images with missing body regions. MedBOE addresses this gap by estimating a patient-specific complete surface model through a three-module pipeline (Fig. 1) tailored for medical imaging. The specific contributions are:

  1. An automated body model reconstruction module that converts whole-body medical images into image-derived incomplete patient body models and annotates anatomically consistent sparse and dense body-surface landmarks for subsequent fitting (Fig. 1(b)).

  2. A medical-image-tailored global parametric fitting strategy that uses attribute-guided optimization to jointly constrain anatomical alignment, body size, and pose plausibility, producing a patient-specific fitted SMPL mesh from incomplete body surfaces (Fig. 1(c)).

  3. A missing body region estimation and surface deformation strategy that combines missing regions estimated from the fitted SMPL mesh with the observed surface to form a complete target. Fine deformation then fits the SMPL mesh to this target with a volume consistency constraint to generate a continuous complete patient body model (Fig. 1(d,e)).

We evaluated MedBOE on two public datasets, AutoPET [22] and Human Implicit Tissues (HIT) [20], and benchmarked it against the state-of-the-art methods adapted from the multimedia domain, demonstrating MedBOE's high accuracy in complete patient body model estimation and BHM derivation. MedBOE achieved the best overall performance among evaluated methods, and MedBOE-derived BHMs were within 2% error, suggesting low percentage errors for downstream analyses. The MedBOE source code and optimization weights are publicly available at https://github.com/Joon-Jung/MedBOE.