arXiv:2610.29104From Canon to Nikon: Camera Domain Shift and Potential Equity Implications in Retinal AI
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
ABSTRACT
Diabetic retinopathy is a leading cause of preventable blindness, yet access to regular screening remains limited worldwide. AI offers a scalable approach, but its performance can be sensitive to image quality and acquisition conditions. In a Brazilian cohort of 8,524 patients, retinal images acquired with the Nikon NF5050 were more than twice as likely to have inadequate image quality compared with those acquired with the Canon CR-2, despite refurbished Canon systems costing more than twice as much as Nikon systems. This potential cost–quality trade-off highlights an important consideration for the reliability of AI systems deployed across heterogeneous imaging systems. Using a frozen pretrained retinal foundation model, we systematically evaluate whether camera-associated performance differences persist across 12 retinal disease classification tasks, four input resolutions, and five downstream classifiers. We find that camera-associated performance differences vary substantially across tasks, and that neither higher input resolution nor classifier choice consistently mitigates cross-camera variation. These findings identify camera platform as a potentially overlooked source of performance variability, with implications for the safety and reliability of retinal AI when deployed across heterogeneous imaging systems. We release all source code, evaluation scripts, and per-task results on on GitHub to support reproducible benchmarking.
1 Introduction
Diabetic retinopathy (DR) is a leading cause of preventable blindness, affecting more than 100 million people worldwide (Teo et al., 2021). The burden is particularly high in low- and middle-income countries, where access to ophthalmic care and regular screening remains limited. Automated analysis of retinal fundus photographs offers a scalable approach to screening, but models that perform well under controlled settings degrade when deployed across different clinical environments (Ting et al., 2017; Beede et al., 2020).
One important source of distribution shift is the fundus camera. Differences in optics, sensors, acquisition protocols, and image-processing pipelines can alter the visual characteristics of retinal photographs and affect model performance. Han et al., for example, reported substantial variation in referable DR detection across fundus-camera models, with performance values ranging from 0.818 to 0.978 (Han et al., 2022). Such variation is particularly relevant to screening programs, where models may encounter imaging systems that were not represented during development.
Brazil provides a relevant setting for studying this problem. Its geographically distributed screening infrastructure relies on heterogeneous imaging equipment, including both high-end desktop systems and lower-cost alternatives. In a Brazilian dataset (BRSET) (Nakayama et al., 2024) involving 8,524 patients, retinal images acquired with the Nikon NF5050 were more than twice as likely to have inadequate image quality compared with those acquired with the Canon CR-2, despite Canon systems costing approximately 2 times as much when refurbished . This potential cost–quality trade-off highlights an important consideration for reliable and equitable AI deployment.
In the latest local refurbished market, Nikon NF5050 is listed at approximately R35,000 (U6,000–6,500), compared with approximately R95,000 (US10,000) for a Canon CR-2 system (Unknown, 2026; Oftalmo Trade, 2026).
Prior studies have examined cross-camera generalization in retinal image analysis, including comparisons between desktop and portable imaging systems (Han et al., 2022; He et al., 2023). While these studies have demonstrated domain shift between desktop and portable systems, less is known about variation across different desktop camera platforms and how this interacts with input resolution and downstream model choice. Moreover, existing studies have largely focused on DR, leaving unclear whether camera-related performance differences extend across other retinal diseases.
We address this literature gap by using RETFound-Green (RFG). RFG is a recently proposed retinal foundation model that is 400x more computationally efficient than its predecessor, substantially reducing the associated emissions (Engelmann & Bernabeu, 2025). Building on the authors' emphasis on computational and environmental efficiency, we investigate whether RFG can also reduce the need for costly fine-tuning by using it as a frozen feature extractor. Freezing the model allows us to reuse the same learned retinal representation across our experimental settings, avoiding repeated fine-tuning across the full set of input-resolution and downstream-classifier combinations. This substantially reduces the computational cost and associated emissions of the experimental evaluation while allowing us to systematically assess the effect of these design choices.
To this end, we evaluate 12 clinical tasks spanning distinct pathological phenotypes, providing a broader assessment than a single DR endpoint. To ensure a fair and leakage-free comparison, we use patient-level partitions throughout, in contrast to the original BRSET benchmark (Nakayama et al., 2024), and report 95% bootstrap confidence intervals.
Retinal foundation model. We intentionally adopt a frozen feature extraction paradigm to leverage RETFound-Green (RFG) (Engelmann & Bernabeu, 2025), a recently proposed retinal foundation model, as a frozen feature extractor for all downstream experiments. RFG is a 22.2-million-parameter vision transformer that was initialized with weights from DINOv2 (Oquab et al., 2023) and subsequently pretrained on retinal images. It uses a “self-supervised Token Reconstruction” objective to capture global image information by incorporating four special learnable vectors to interact with the image patch tokens through self-attention. During training, a frozen copy of the model processes the original image to produce target tokens, while a second copy receives a noisy version of the same image and is trained to reconstruct these tokens. The reter tokens therefore participate in the self-attention process and are learned together with the rest of the model during retinal pretraining. RFG was pretrained on 75,000 retinal fundus photographs using less than $100 of computational resources, 400× less compute than its predecessors (Engelmann & Bernabeu, 2025).
Experimental setup. We evaluated five downstream classifiers: support vector machine (SVM), k-nearest neighbors (kNN), histogram-based gradient boosting (HGB), logistic regression (LR), and random forest (RF). These classifiers span linear, margin-based, instance-based, and tree-based approaches. All classifiers were evaluated using the same RFG embeddings and under the same patient-level data partitions. The experimental factors were camera platform, input resolution, classifier, and diagnostic task. We evaluated 12 retinal disease classification tasks across four input resolutions (224, 392, 672, and 952 pixels) and five classifiers.
Camera-domain evaluation. To evaluate camera-associated domain shift, we separated evaluation by camera platform rather than pooling images from both cameras. The Canon cohort was used as the source domain and the Nikon cohort as the target domain. Models were trained and inter-nally selected using source-camera data and subsequently evaluated on the held-out target-camera data without further model fitting. This source-to-target evaluation measures whether a classifier trained on one camera platform maintains performance when applied to images acquired with another platform. Within-camera performance was also evaluated to distinguish general classification performance from cross-camera degradation.
Input resolution. We evaluated four input resolutions: 224, 392, 672, and 952 pixels. The resolution provides a commonly used baseline, while corresponds to the input resolution used for RFG pretraining. The resolution provides an intermediate, non-dyadic scaling relative to , allowing us to assess whether performance changes smoothly with resolution or depends on the particular resampling scale. Finally, was selected to maintain compatibility with the model's patch structure. All four resolutions are divisible by 14, corresponding to patch grids of , , , and , respectively.
Model selection and evaluation. For each diagnostic task and input resolution, classifier hyperparameters were selected using only the source-camera training and validation data. The selected model was then evaluated on the held-out source-camera test set and the target-camera test set without further tuning. For binary classification tasks, performance was measured using area under the receiver operating characteristic curve (AUROC). For DR staging, quadratic weighted kappa (QWK) was used as the primary metric. Performance estimates are reported with bootstrap confidence intervals. All data partitions were performed at the patient level to ensure that images from the same patient did not occur across training, validation, and test partitions.
3 Results
Image quality differs across camera platforms. Image quality differed between the two camera platforms (Table 1). Inadequate images were more frequent in the Nikon NF5050 cohort than in the Canon CR-2 cohort (18.6% vs. 8.8%; , , Cramér's ). The largest difference occurred for image-field adequacy, which was classified as inadequate in 15.84% of Nikon images compared with 4.76% of Canon images (, ). In contrast, focus and artifact adequacy showed little association with camera platform ( and , respectively). Illumination showed a statistically significant but weak association (, ). These results indicate that camera platform in BRSET is associated not only with image acquisition characteristics but also with image quality, an important consideration when interpreting subsequent camera-domain comparisons.
Camera-associated performance varies across disease tasks. Camera-associated differences in performance were heterogeneous across diagnostic tasks. Table 2 summarizes our experimental results, while all 240 comparisons (12 tasks × 4 resolutions × 5 classifiers) and corresponding 95% confidence intervals are provided in the Appendix. Several tasks showed little difference between the Canon and Nikon cohorts. For example, AUROC was similar for diabetic retinopathy (0.940 vs. 0.946), scar (0.964 vs. 0.955), and macular edema (0.952 vs. 0.952). In contrast, larger reductions were observed for hemorrhage (0.804 vs. 0.569), hypertensive retinopathy (0.864 vs. 0.690), and DR staging (0.692 vs. 0.527). Other tasks showed intermediate differences, including AMD (0.976 vs. 0.909) and nevus (0.840 vs. 0.795). Thus, camera-associated performance differences were not uniform across disease phenotypes. The same camera shift that produced substantial degradation for some tasks had little apparent effect on others.
Table 1: Percentage of images classified as inadequate for each image-quality criterion by camera platform, with corresponding camera–quality association statistics. Cramér's V quantifies the strength of association between camera platform and each quality criterion.
| Camera | Overall | Focus | Illumination | Image field | Artifacts |
|---|---|---|---|---|---|
| Canon CR | 8.79% | 3.57% | 0.67% | 4.76% | 0.35% |
| Nikon NF5050 | 18.60% | 2.90% | 0.23% | 15.84% | 0.35% |
| Cramér's V (p) | 0.142 (< 0.001) | 0.018 (0.065) | 0.028 (< 0.001) | 0.188 (< 0.001) | 0.000 (1.000) |
Table 2: Best-performing classifier (selected by internal validation AUROC, or QWK for DR staging) per task, with internal (train and test images acquired using Canon) and external (Canon for training and Nikon for test) performance at the selected resolution. Values show point estimate with 95% bootstrap confidence interval. Cell color encodes the magnitude of the performance drop relative to the Canon reference split: yellow for drops up to 10 percentage points, red for larger drops.
| Task | Alg | Resolution | Internal | External |
|---|---|---|---|---|
| DR Staging (ICDR) | HGB | 392 | 0.692 (0.615–0.765) | 0.527 (0.478–0.577) |
| Scar | LR | 392 | 0.964 (0.926–0.986) | 0.955 (0.923–0.977) |
| Diabetic Retinopathy | LR | 672 | 0.940 (0.916–0.963) | 0.946 (0.932–0.957) |
| Hemorrhage | LR | 672 | 0.804 (0.670–0.891) | 0.569 (0.451–0.716) |
| AMD | LR | 952 | 0.976 (0.961–0.987) | 0.909 (0.857–0.948) |
| Nevus | LR | 952 | 0.840 (0.729–0.903) | 0.795 (0.711–0.886) |
| Other | LR | 952 | 0.828 (0.784–0.858) | 0.740 (0.708–0.774) |
| Hypertensive Retinopathy | RF | 392 | 0.864 (0.809–0.909) | 0.690 (0.635–0.745) |
| Macular Edema | RF | 392 | 0.952 (0.928–0.975) | 0.952 (0.931–0.965) |
| Vascular Occlusion | RF | 392 | 0.954 (0.913–0.992) | 0.906 (0.835–0.971) |
| Increased Cup/Disc | SVM | 392 | 0.871 (0.855–0.888) | 0.850 (0.836–0.863) |
| Myopic Fundus | SVM | 952 | 0.991 (0.986–0.994) | 0.975 (0.963–0.984) |
Downstream classifier choice has a smaller effect than camera platform. Classifier performance varied across tasks. Linear and nonlinear classifiers each achieved the best performance on different tasks; no single classifier consistently dominated across tasks. This suggests that, under a frozen retinal foundation-model representation, downstream classifier choice is task-dependent and does not by itself eliminate camera-associated performance differences.
4 Discussion & Conclusions
Our results show that camera-associated domain shift persists even when using a frozen retinal foundation model. Performance varied across camera platforms and disease tasks, with some tasks showing little change and others showing substantial reductions in target-camera performance. This heterogeneity suggests that camera shift is not uniform across retinal diseases.
Increasing input resolution and changing the downstream classifier did not consistently eliminate camera-associated performance differences. These findings suggest that higher-resolution inputs or more complex classifiers alone are unlikely to provide a general solution to cross-camera generalization.
Image quality provides an important context for interpreting these results. Inadequate images were more common in the Nikon cohort than in the Canon cohort (18.6% vs. 8.8%), particularly because of differences in image-field adequacy. Thus, the observed camera effect may reflect both differences in image acquisition and image quality. However, the available data do not permit these factors to be fully disentangled because of the inherent limitations of the dataset.
Overall, our findings highlight the importance of evaluating retinal AI systems across the imaging platforms encountered in practice. Reporting performance by camera, rather than relying only on aggregate test performance, can reveal failures that may otherwise remain hidden.
This study is limited by the use of two camera platforms within a single dataset and by the confounding between camera platform and image quality. Future work should evaluate additional cameras and datasets and test whether image-quality control or domain-adaptation methods can reduce the observed shift.
Overall, camera-associated domain shift remains an important consideration even with modern retinal foundation models. Robust deployment therefore requires evaluation across both imaging conditions and disease tasks, rather than assuming that a strong representation will generalize across cameras.
REFERENCES
Emma Beede, Elizabeth Baylor, Fred Hersch, Anna Iurchenko, Lauren Chang, Lauren Wilcox, Rory Sayres, Katherine Chou, Kasumi Wedjakum, Nampetch Sandhu, et al. A human-centered evaluation of a deep learning system deployed in clinics for the detection of diabetic retinopathy. In Proceedings of the 2020 CHI Conference on Human Factors in Computing Systems, pp. 1–12, 2020.
Justin Engelmann and Miguel O Bernabeu. Training a high-performance retinal foundation model with half-the-data and 400 times less compute. Nature Communications, 16(1):6862, 2025.
Ruoan Han, Gangwei Cheng, Bilei Zhang, Jingyuan Yang, Mingzhen Yuan, Dalu Yang, Junde Wu, Junwei Liu, Chan Zhao, Youxin Chen, et al. Validating automated eye disease screening ai algorithm in community and in-hospital scenarios. Frontiers in public health, 10:944967, 2022.
Shuang He, Gabriella Bulloch, Liangxin Zhang, Yiyu Xie, Weiyu Wu, Yahong He, Wei Meng, Danli Shi, and Mingguang He. Cross-camera performance of deep learning algorithms to diagnose common ophthalmic diseases: A comparative study highlighting feasibility to portable fundus camera use. Current Eye Research, 48(9):857–863, 2023. doi: 10.1080/02713683.2023.2215984.
Luis Filipe Nakayama, Rafael Gonçalves, Lucas Zago Ribeiro, et al. A Brazilian multilabel ophthalmological dataset (brset). PLOS Digital Health, 3(3):e0000454, 2024. doi: 10.1371/journal.pdig.0000454. URL https://doi.org.
Oftalmo Trade. Retinógrafo digital canon CR-2. https://web.archive.org/web/20260830031445/https://www.oftalmotrade.com/produto/1418/retinografo-digital-canon-cr2, 2026. Accessed August 29, 2026.
Maxime Oquab, Timothée Darcet, Théo Moutakanni, Huy Vo, Marc Szafraniec, Vasil Khalidov, Pierre Fernandez, Daniel Haziza, Francisco Massa, Alaaeldin El-Nouby, et al. Dinov2: Learning robust visual features without supervision. arXiv preprint arXiv:2304.07193, 2023.
Zhen Ling Teo, Mei Ling Chee, Paul Mitchell, Ching-Yu Cheng, Tien Yin Wong, Charumathi Sabanayagam, et al. Global prevalence of diabetic retinopathy and projection of burden through 2045: systematic review and meta-analysis. Ophthalmology, 128(11):1580–1591, 2021.
Daniel Shu Wei Ting, Carol Yim-Lui Cheung, Gilbert Lim, Tan Nyip Tan, Nguyen D Quang, Amitha Gan, Haslina Hamzah, Rafael Garcia-Franco, I-Van San Yeo, Shu Yen Lee, et al. Development and validation of a deep learning system for diabetic retinopathy and related eye diseases using retinal images from multiethnic populations with diabetes. JAMA, 318(22):2211–2223, 2017.
Unknown. Nikon NF 505 Retinógrafo. https://web.archive.org/web/20260830031732/https://br.pinterest.com/pin/649503577498067880/, 2026. Accessed August 29, 2026.
A APPENDIX
A.1 EXPERIMENTAL SETUP
Table 3 summarizes the variables we examined in this work.
Table 3: Experimental factors and levels.
| Factor | Camera | Resolution | Classifier |
|---|---|---|---|
| Levels | Canon CR-2, Nikon NF5050 | 224, 392, 672, 952 | SVM, kNN, HGB, LR, RF |
| Factor | Tasks / Extractor | Evaluation | Domain |
| Levels | 12 tasks / Frozen RFG | Patient-level | Within / Cross-camera* |

Figure 1: A sample retinal fundus photograph captured using Canon CR-2 for a female patient.
A.2 RESULTS
Table 4: Full classifier × resolution results per task. Internal = held-out Canon test set; External = unseen Nikon cohort. Values show point estimate with 95% bootstrap confidence interval. Metric is QWK for DR staging (ordinal, 5-class ICDR) and AUROC for all other (binary) tasks.
| Task | Alg | Resolution | Internal | External |
|---|---|---|---|---|
| DR Staging (ICDR) | SVM | 224 | 0.611 (0.508–0.682) | 0.669 (0.619–0.728) |
| 392 | 0.635 (0.549–0.725) | 0.705 (0.657–0.752) | ||
| 672 | 0.662 (0.581–0.739) | 0.716 (0.671–0.760) | ||
| 952 | 0.538 (0.452–0.635) | 0.657 (0.610–0.701) | ||
| LR | 224 | 0.579 (0.524–0.629) | 0.601 (0.551–0.652) | |
| 392 | 0. (0.606–0.699) | 0.579 (0.538–0.632) | ||
| 672 | 0.637 (0.580–0.699) | 0.503 (0.469–0.550) | ||
| 952 | 0.587 (0.523–0.656) | 0.549 (0.513–0.596) | ||
| HGB | 224 | 0.642 (0.549–0.715) | 0.580 (0.525–0.634) | |
| 392 | 0.692 (0.615–0.765) | 0.527 (0.478–0.577) | ||
| 672 | 0.574 (0.499–0.672) | 0.350 (0.284–0.410) | ||
| 952 | 0.516 (0.415–0.607) | 0.292 (0.207–0.359) | ||
| kNN | 224 | 0.487 (0.390–0.590) | 0.276 (0.215–0.353) | |
| 392 | 0.469 (0.372–0.584) | 0.229 (0.166–0.291) | ||
| 672 | 0.329 (0.216–0.443) | 0.130 (0.076–0.195) | ||
| 952 | 0.296 (0.179–0.407) | 0.112 (0.061–0.164) | ||
| RF | 224 | 0.301 (0.192–0.409) | 0.065 (0.026–0.107) | |
| 392 | 0.262 (0.165–0.386) | 0.074 (0.031–0.116) | ||
| 672 | 0.203 (0.087–0.310) | 0.018 (-0.001–0.043) | ||
| 952 | 0.142 (0.051–0.250) | 0.019 (0.000–0.044) | ||
| Diabetic Retinopathy | SVM | 224 | 0.887 (0.847–0.915) | 0.893 (0.872–0.911) |
| 392 | 0.933 (0.905–0.954) | 0.930 (0.915–0.946) | ||
| 672 | 0.934 (0.906–0.958) | 0.936 (0.918–0.949) | ||
| 952 | 0.935 (0.910–0.953) | 0.912 (0.893–0.926) | ||
| LR | 224 | 0.893 (0.859–0.922) | 0.906 (0.886–0.924) | |
| 392 | 0.933 (0.907–0.956) | 0.940 (0.926–0.954) | ||
| 672 | 0.940 (0.916–0.963) | 0.946 (0.932–0.957) | ||
| 952 | 0.938 (0.912–0.957) | 0.930 (0.914–0.943) | ||
| HGB | 224 | 0.900 (0.869–0.926) | 0.897 (0.878–0.919) | |
| 392 | 0.926 (0.903–0.948) | 0.933 (0.915–0.948) | ||
| 672 | 0.919 (0.890–0.941) | 0.924 (0.907–0.941) | ||
| 952 | 0.911 (0.890–0.932) | 0.907 (0.893–0.924) | ||
| kNN | 224 | 0.817 (0.778–0.853) | 0.796 (0.763–0.821) | |
| 392 | 0.837 (0.800–0.871) | 0.829 (0.802–0.856) | ||
| 672 | 0.808 (0.765–0.853) | 0.794 (0.767–0.822) | ||
| 952 | 0.770 (0.723–0.815) | 0.770 (0.745–0.795) | ||
| RF | 224 | 0.894 (0.864–0.918) | 0.891 (0.871–0.911) | |
| 392 | 0.913 (0.883–0.939) | 0.931 (0.917–0.945) | ||
| 672 | 0.908 (0.886–0.936) | 0.927 (0.912–0.941) | ||
| 952 | 0.889 (0.863–0.914) | 0.893 (0.877–0.908) | ||
| SVM | 224 | 0.925 (0.887–0.959) | 0.906 (0.870–0.941) | |
| 392 | 0.948 (0.912–0.973) | 0.888 (0.844–0.928) | ||
| 672 | 0.971 (0.958–0.984) | 0.889 (0.842–0.932) | ||
| 952 | 0.965 (0.936–0.985) | 0.890 (0.829–0.935) | ||
| LR | 224 | 0.941 (0.910–0.968) | 0.907 (0.873–0.937) | |
| 392 | 0.962 (0.939–0.979) | 0.901 (0.865–0.941) | ||
| 672 | 0.975 (0.958–0.989) | 0.915 (0.873–0.951) | ||
| 952 | 0.976 (0.961–0.987) | 0.909 (0.857–0.948) |
AMD
Continued on next page
Table 4 – continued from previous page
| Task | Alg | Resolution | Internal | External |
|---|---|---|---|---|
| Hemorrhage | HGB | 224 | 0.958 (0.939–0.973) | 0.821 (0.751–0.870) |
| 392 | 0.960 (0.938–0.978) | 0.839 (0.779–0.883) | ||
| 672 | 0.972 (0.956–0.984) | 0.819 (0.768–0.875) | ||
| 952 | 0.967 (0.949–0.982) | 0.831 (0.772–0.891) | ||
| kNN | 224 | 0.794 (0.719–0.847) | 0.671 (0.614–0.725) | |
| 392 | 0.857 (0.786–0.905) | 0.741 (0.682–0.806) | ||
| 672 | 0.899 (0.851–0.946) | 0.704 (0.638–0.762) | ||
| 952 | 0.849 (0.802–0.899) | 0.737 (0.672–0.795) | ||
| RF | 224 | 0.943 (0.916–0.962) | 0.790 (0.711–0.855) | |
| 392 | 0.954 (0.930–0.974) | 0.829 (0.761–0.877) | ||
| 672 | 0.958 (0.933–0.980) | 0.813 (0.744–0.866) | ||
| 952 | 0.958 (0.938–0.973) | 0.804 (0.715–0.865) | ||
| Hemorrhage | SVM | 224 | 0.782 (0.619–0.888) | 0.586 (0.454–0.710) |
| 392 | 0.709 (0.559–0.797) | 0.568 (0.453–0.700) | ||
| 672 | 0.779 (0.657–0.867) | 0.555 (0.432–0.685) | ||
| 952 | 0.705 (0.560–0.808) | 0.572 (0.470–0.697) | ||
| LR | 224 | 0.794 (0.619–0.906) | 0.601 (0.478–0.733) | |
| 392 | 0.754 (0.599–0.840) | 0.580 (0.456–0.707) | ||
| 672 | 0.804 (0.670–0.891) | 0.569 (0.451–0.716) | ||
| 952 | 0.728 (0.565–0.841) | 0.594 (0.491–0.723) | ||
| HGB | 224 | 0.705 (0.506–0.824) | 0.682 (0.552–0.784) | |
| 392 | 0.757 (0.537–0.887) | 0.610 (0.511–0.738) | ||
| 672 | 0.738 (0.584–0.884) | 0.676 (0.579–0.794) | ||
| 952 | 0.701 (0.485–0.864) | 0.674 (0.540–0.775) | ||
| kNN | 224 | 0.622 (0.519–0.733) | 0.551 (0.480–0.624) | |
| 392 | 0.596 (0.478–0.694) | 0.583 (0.499–0.665) | ||
| 672 | 0.500 (0.463–0.550) | 0.534 (0.478–0.612) | ||
| 952 | 0.533 (0.469–0.620) | 0.569 (0.502–0.648) | ||
| RF | 224 | 0.785 (0.621–0.907) | 0.749 (0.670–0.806) | |
| 392 | 0.785 (0.593–0.907) | 0.727 (0.630–0.823) | ||
| 672 | 0.725 (0.516–0.884) | 0.696 (0.558–0.824) | ||
| 952 | 0.707 (0.560–0.848) | 0.746 (0.627–0.846) | ||
| Hypertensive Retinopathy | SVM | 224 | 0.703 (0.597–0.805) | 0.530 (0.470–0.579) |
| 392 | 0.793 (0.719–0.877) | 0.523 (0.462–0.567) | ||
| 672 | 0.776 (0.682–0.857) | 0.567 (0.507–0.618) | ||
| 952 | 0.776 (0.688–0.864) | 0.532 (0.478–0.586) | ||
| LR | 224 | 0.734 (0.645–0.836) | 0.568 (0.511–0.621) | |
| 392 | 0.840 (0.774–0.914) | 0.564 (0.502–0.609) | ||
| 672 | 0.822 (0.739–0.901) | 0.599 (0.546–0.648) | ||
| 952 | 0.803 (0.721–0.879) | 0.552 (0.494–0.601) | ||
| HGB | 224 | 0.818 (0.747–0.889) | 0.664 (0.625–0.708) | |
| 392 | 0.826 (0.741–0.891) | 0.663 (0.601–0.710) | ||
| 672 | 0.799 (0.723–0.856) | 0.673 (0.617–0.715) | ||
| 952 | 0.761 (0.696–0.832) | 0.634 (0.586–0.698) | ||
| kNN | 224 | 0.646 (0.575–0.732) | 0.547 (0.503–0.607) | |
| 392 | 0.673 (0.607–0.762) | 0.568 (0.530–0.607) | ||
| 672 | 0.616 (0.554–0.698) | 0.517 (0.466–0.567) | ||
| 952 | 0.617 (0.545–0.710) | 0.502 (0.462–0.551) | ||
| RF | 224 | 0.797 (0.694–0.870) | 0.690 (0.629–0.753) | |
| 392 | 0.864 (0.809–0.909) | 0.690 (0.635–0.745) | ||
| 672 | 0.820 (0.731–0.875) | 0.622 (0.579–0.672) | ||
| 952 | 0.794 (0.725–0.848) | 0.628 (0.587–0.679) | ||
| SVM | 224 | 0.853 (0.836–0.869) | 0.829 (0.817–0.841) | |
| 392 | 0.871 (0.855–0.888) | 0.850 (0.836–0.863) |
Continued on next page
8
Journal of Oncology
Table 4 – continued from previous page
| Task | Alg | Resolution | Internal | External |
|---|---|---|---|---|
| Macular Edema | 672 | 0.865 (0.848–0.879) | 0.844 (0.827–0.855) | |
| 952 | 0.859 (0.838–0.872) | 0.843 (0.829–0.855) | ||
| LR | 224 | 0.854 (0.838–0.872) | 0.839 (0.828–0.850) | |
| 392 | 0.870 (0.854–0.887) | 0.856 (0.843–0.869) | ||
| 672 | 0.868 (0.851–0.882) | 0.852 (0.837–0.864) | ||
| 952 | 0.862 (0.841–0.874) | 0.846 (0.831–0.857) | ||
| HGB | 224 | 0.804 (0.781–0.823) | 0.749 (0.730–0.767) | |
| 392 | 0.813 (0.790–0.830) | 0.793 (0.777–0.807) | ||
| 672 | 0.818 (0.800–0.835) | 0.783 (0.766–0.799) | ||
| 952 | 0.819 (0.799–0.836) | 0.781 (0.762–0.795) | ||
| kNN | 224 | 0.737 (0.710–0.760) | 0.683 (0.662–0.703) | |
| 392 | 0.729 (0.700–0.751) | 0.699 (0.676–0.714) | ||
| 672 | 0.735 (0.715–0.758) | 0.678 (0.658–0.695) | ||
| 952 | 0.719 (0.694–0.739) | 0.664 (0.642–0.684) | ||
| RF | 224 | 0.782 (0.759–0.801) | 0.746 (0.730–0.766) | |
| 392 | 0.790 (0.773–0.808) | 0.784 (0.767–0.801) | ||
| 672 | 0.793 (0.771–0.808) | 0.782 (0.765–0.798) | ||
| 952 | 0.792 (0.771–0.808) | 0.783 (0.767–0.798) | ||
| Myopic Fundus | SVM | 224 | 0.881 (0.820–0.949) | 0.961 (0.941–0.978) |
| 392 | 0.897 (0.815–0.969) | 0.984 (0.975–0.991) | ||
| 672 | 0.916 (0.856–0.973) | 0.983 (0.976–0.989) | ||
| 952 | 0.917 (0.867–0.970) | 0.979 (0.965–0.989) | ||
| LR | 224 | 0.906 (0.853–0.962) | 0.968 (0.948–0.985) | |
| 392 | 0.913 (0.839–0.974) | 0.987 (0.980–0.994) | ||
| 672 | 0.927 (0.875–0.978) | 0.990 (0.986–0.993) | ||
| 952 | 0.928 (0.883–0.977) | 0.982 (0.970–0.992) | ||
| HGB | 224 | 0.946 (0.919–0.969) | 0.946 (0.929–0.959) | |
| 392 | 0.934 (0.895–0.971) | 0.965 (0.951–0.978) | ||
| 672 | 0.945 (0.909–0.976) | 0.962 (0.949–0.974) | ||
| 952 | 0.939 (0.911–0.966) | 0.963 (0.953–0.974) | ||
| kNN | 224 | 0.809 (0.724–0.878) | 0.851 (0.816–0.888) | |
| 392 | 0.844 (0.781–0.893) | 0.901 (0.871–0.936) | ||
| 672 | 0.765 (0.678–0.847) | 0.842 (0.808–0.892) | ||
| 952 | 0.750 (0.671–0.814) | 0.786 (0.752–0.840) | ||
| RF | 224 | 0.942 (0.917–0.964) | 0.936 (0.916–0.959) | |
| 392 | 0.952 (0.928–0.975) | 0.952 (0.931–0.965) | ||
| 672 | 0.948 (0.920–0.970) | 0.954 (0.936–0.969) | ||
| 952 | 0.926 (0.889–0.955) | 0.954 (0.935–0.969) | ||
| Myopic Fundus | SVM | 224 | 0.960 (0.923–0.986) | 0.975 (0.965–0.983) |
| 392 | 0.974 (0.953–0.991) | 0.978 (0.966–0.989) | ||
| 672 | 0.990 (0.984–0.994) | 0.972 (0.959–0.986) | ||
| 952 | 0.991 (0.986–0.994) | 0.975 (0.963–0.984) | ||
| LR | 224 | 0.970 (0.944–0.990) | 0.985 (0.979–0.991) | |
| 392 | 0.981 (0.965–0.992) | 0.983 (0.972–0.991) | ||
| 672 | 0.989 (0.983–0.994) | 0.978 (0.958–0.992) | ||
| 952 | 0.989 (0.984–0.993) | 0.977 (0.968–0.989) | ||
| HGB | 224 | 0.981 (0.970–0.991) | 0.965 (0.942–0.986) | |
| 392 | 0.986 (0.978–0.993) | 0.990 (0.984–0.994) | ||
| 672 | 0.982 (0.973–0.989) | 0.975 (0.955–0.989) | ||
| 952 | 0.983 (0.971–0.990) | 0.972 (0.952–0.989) | ||
| kNN | 224 | 0.905 (0.838–0.960) | 0.878 (0.835–0.925) | |
| 392 | 0.890 (0.826–0.955) | 0.864 (0.817–0.927) | ||
| 672 | 0.892 (0.827–0.951) | 0.882 (0.841–0.924) | ||
| 952 | 0.892 (0.827–0.950) | 0.835 (0.782–0.888) |
Continued on next page
Table 4 – continued from previous page
| Task | Alg | Resolution | Internal | External |
|---|---|---|---|---|
| RF | 224 | 0.980 (0.971–0.990) | 0.975 (0.955–0.991) | |
| 392 | 0.983 (0.975–0.991) | 0.989 (0.982–0.994) | ||
| 672 | 0.983 (0.975–0.991) | 0.986 (0.979–0.993) | ||
| 952 | 0.981 (0.972–0.989) | 0.981 (0.969–0.990) | ||
| Nevus | SVM | 224 | 0.721 (0.614–0.854) | 0.724 (0.632–0.815) |
| 392 | 0.685 (0.578–0.803) | 0.751 (0.654–0.839) | ||
| 672 | 0.822 (0.749–0.878) | 0.771 (0.682–0.861) | ||
| 952 | 0.830 (0.712–0.893) | 0.795 (0.710–0.885) | ||
| LR | 224 | 0.724 (0.610–0.847) | 0.738 (0.659–0.831) | |
| 392 | 0.708 (0.601–0.827) | 0.754 (0.662–0.842) | ||
| 672 | 0.832 (0.772–0.894) | 0.775 (0.692–0.858) | ||
| 952 | 0.840 (0.729–0.903) | 0.795 (0.711–0.886) | ||
| HGB | 224 | 0.521 (0.380–0.643) | 0.617 (0.517–0.703) | |
| 392 | 0.582 (0.435–0.694) | 0.683 (0.582–0.781) | ||
| 672 | 0.607 (0.503–0.731) | 0.666 (0.570–0.746) | ||
| 952 | 0.526 (0.364–0.646) | 0.591 (0.490–0.687) | ||
| kNN | 224 | 0.553 (0.480–0.658) | 0.520 (0.461–0.593) | |
| 392 | 0.473 (0.424–0.549) | 0.538 (0.469–0.605) | ||
| 672 | 0.514 (0.456–0.602) | 0.546 (0.477–0.607) | ||
| 952 | 0.490 (0.439–0.562) | 0.593 (0.508–0.671) | ||
| RF | 224 | 0.548 (0.396–0.659) | 0.610 (0.493–0.720) | |
| 392 | 0.493 (0.387–0.592) | 0.644 (0.544–0.740) | ||
| 672 | 0.563 (0.423–0.670) | 0.634 (0.529–0.725) | ||
| 952 | 0.539 (0.401–0.647) | 0.548 (0.451–0.650) | ||
| Other | SVM | 224 | 0.808 (0.770–0.842) | 0.695 (0.659–0.732) |
| 392 | 0.789 (0.725–0.828) | 0.720 (0.692–0.750) | ||
| 672 | 0.796 (0.748–0.832) | 0.695 (0.663–0.731) | ||
| 952 | 0.808 (0.757–0.840) | 0.712 (0.680–0.747) | ||
| LR | 224 | 0.822 (0.785–0.852) | 0.729 (0.694–0.762) | |
| 392 | 0.804 (0.750–0.845) | 0.749 (0.721–0.781) | ||
| 672 | 0.812 (0.768–0.847) | 0.727 (0.698–0.758) | ||
| 952 | 0.828 (0.784–0.858) | 0.740 (0.708–0.774) | ||
| HGB | 224 | 0.796 (0.753–0.827) | 0.697 (0.669–0.724) | |
| 392 | 0.785 (0.751–0.819) | 0.722 (0.700–0.745) | ||
| 672 | 0.797 (0.766–0.832) | 0.736 (0.706–0.768) | ||
| 952 | 0.803 (0.767–0.832) | 0.732 (0.706–0.765) | ||
| kNN | 224 | 0.673 (0.620–0.720) | 0.595 (0.564–0.630) | |
| 392 | 0.671 (0.623–0.716) | 0.625 (0.599–0.657) | ||
| 672 | 0.660 (0.606–0.703) | 0.614 (0.581–0.641) | ||
| 952 | 0.615 (0.563–0.670) | 0.606 (0.577–0.636) | ||
| RF | 224 | 0.790 (0.750–0.824) | 0.732 (0.700–0.761) | |
| 392 | 0.789 (0.759–0.822) | 0.735 (0.709–0.761) | ||
| 672 | 0.782 (0.745–0.816) | 0.746 (0.722–0.778) | ||
| 952 | 0.798 (0.761–0.826) | 0.749 (0.718–0.780) | ||
| Scar | SVM | 224 | 0.927 (0.849–0.979) | 0.961 (0.943–0.976) |
| 392 | 0.948 (0.895–0.977) | 0.947 (0.916–0.973) | ||
| 672 | 0.955 (0.920–0.977) | 0.943 (0.908–0.969) | ||
| 952 | 0.942 (0.892–0.973) | 0.953 (0.924–0.976) | ||
| LR | 224 | 0.945 (0.887–0.989) | 0.958 (0.937–0.979) | |
| 392 | 0.964 (0.926–0.986) | 0.955 (0.923–0.977) | ||
| 672 | 0.959 (0.915–0.982) | 0.957 (0.925–0.977) | ||
| 952 | 0.952 (0.910–0.982) | 0.957 (0.934–0.978) | ||
| HGB | 224 | 0.925 (0.861–0.974) | 0.938 (0.911–0.961) | |
| 392 | 0.927 (0.838–0.971) | 0.910 (0.867–0.939) |
Continued on next page
Table 4 – continued from previous page
| Task | Alg | Resolution | Internal | External |
|---|---|---|---|---|
| 672 | 0.928 (0.876–0.963) | 0.930 (0.892–0.956) | ||
| 952 | 0.925 (0.837–0.974) | 0.930 (0.892–0.960) | ||
| kNN | 224 | 0.769 (0.675–0.857) | 0.815 (0.767–0.863) | |
| 392 | 0.781 (0.683–0.864) | 0.816 (0.759–0.854) | ||
| 672 | 0.754 (0.677–0.841) | 0.781 (0.731–0.827) | ||
| 952 | 0.737 (0.661–0.820) | 0.768 (0.718–0.822) | ||
| RF | 224 | 0.921 (0.854–0.963) | 0.920 (0.892–0.948) | |
| 392 | 0.923 (0.833–0.968) | 0.897 (0.844–0.932) | ||
| 672 | 0.919 (0.827–0.969) | 0.917 (0.869–0.945) | ||
| 952 | 0.920 (0.843–0.967) | 0.928 (0.888–0.957) | ||
| Vascular Occlusion | SVM | 224 | 0.913 (0.834–0.968) | 0.935 (0.889–0.978) |
| 392 | 0.929 (0.865–0.968) | 0.919 (0.831–0.985) | ||
| 672 | 0.913 (0.824–0.975) | 0.932 (0.870–0.982) | ||
| 952 | 0.872 (0.773–0.946) | 0.921 (0.861–0.973) | ||
| LR | 224 | 0.923 (0.853–0.967) | 0.943 (0.906–0.980) | |
| 392 | 0.950 (0.904–0.978) | 0.930 (0.857–0.988) | ||
| 672 | 0.917 (0.833–0.970) | 0.943 (0.886–0.985) | ||
| 952 | 0.894 (0.809–0.955) | 0.934 (0.877–0.978) | ||
| HGB | 224 | 0.938 (0.892–0.973) | 0.814 (0.716–0.937) | |
| 392 | 0.949 (0.914–0.990) | 0.878 (0.800–0.960) | ||
| 672 | 0.902 (0.824–0.970) | 0.784 (0.665–0.897) | ||
| 952 | 0.794 (0.653–0.907) | 0.791 (0.693–0.902) | ||
| kNN | 224 | 0.833 (0.714–0.934) | 0.778 (0.679–0.906) | |
| 392 | 0.831 (0.722–0.932) | 0.769 (0.647–0.891) | ||
| 672 | 0.808 (0.683–0.906) | 0.732 (0.645–0.820) | ||
| 952 | 0.740 (0.607–0.849) | 0.769 (0.665–0.878) | ||
| RF | 224 | 0.941 (0.863–0.990) | 0.902 (0.826–0.966) | |
| 392 | 0.954 (0.913–0.992) | 0.906 (0.835–0.971) | ||
| 672 | 0.920 (0.840–0.987) | 0.934 (0.887–0.973) | ||
| 952 | 0.930 (0.862–0.977) | 0.868 (0.767–0.941) |

Figure 2: Effect of input resolution on cross-camera generalization for 12 BRSET predictive tasks. Area under the receiver operating characteristic curve (AUROC) for a Logistic Regression trained on frozen RetFound-Green (RFG) embeddings, evaluated at four input resolutions (224, 392, 672, 952 px). Internal (dotted orange) denotes the held-out Canon test split (patient-disjoint from training; n=2,191); External (solid blue) denotes the Nikon subset (n=5,639), representing a distinct camera never seen during training. Shaded regions show 95% confidence intervals from 100 bootstrap resamples. Most binary pathology labels (e.g., diabetic retinopathy, macular edema, myopic fundus) show overlapping internal/external intervals across resolutions, indicating that RFG embeddings support camera-invariant discrimination for these tasks. In contrast, hemorrhage and hypertensive retinopathy show consistent, non-overlapping degradation under external evaluation ( AUROC=0.15–0.28), suggesting these labels are more sensitive to camera-specific color/optical characteristics than to the classifier itself.

Figure 3: Effects if using a Support Vector Machine. Same setup as Figure 2 (frozen RFG embeddings, 4 resolutions, internal Canon test vs. external Nikon cohort, 95% bootstrap CIs).

Figure 4: Effects if using HGB. Same setup as Figure 2 (frozen RFG embeddings, 4 resolutions, internal Canon test vs. external Nikon cohort, 95% bootstrap CIs).

Figure 5: Effects if using kNN. Same setup as Figure 2 (frozen RFG embeddings, 4 resolutions, internal Canon test vs. external Nikon cohort, 95% bootstrap CIs).