arXiv:2610.29141cs.CVOct 2026

Manuscript Offprint

arXiv:2610.29141

DGCM-SSFA: Dual-Granularity Cross-Modulation and Sparse Strip Frequency Attention for Efficient 3T-to-7T MRI Synthesis

Zhichun Fan, Zhiqiang Chen, Lanling Liu, Lingjun Liu, Zhonghua Xie

Zhichun Fan, Zhiqiang Chen, Lanling Liu, Lingjun Liu, Zhonghua Xie ∗^{*}

School of Computer Science and Engineering, Huizhou University, Huizhou, China

Abstract—Synthesizing high-fidelity 7T MRI from routinely acquired 3T scans offers a practical pathway to enhanced neuroimaging without the prohibitive cost of ultra-high-field scanners. While existing deep learning approaches have achieved promising results, state-of-the-art methods typically rely on either large-scale architectures exceeding 45 million parameters or computationally intensive ensemble strategies, limiting their practicality in resource-constrained clinical environments. In this work, we propose a compact multi-domain attention framework, termed DGCM-SSFA, that achieves competitive synthesis quality with only 11M parameters. The proposed architecture integrates two complementary modules into a U-Net Transformer backbone. First, a Dual-Granularity Cross-Modulated Feature Modulator (DGCM) is embedded at multiple hierarchical levels to enhance local edge and texture details through Sobel-guided spatial attention and depthwise frequency-aware channel attention with cross-branch gating. Second, a Sparse Strip Frequency Attention (SSFA) module at the bottleneck captures global spatial context via strip-pooled attention with near-linear complexity, while simultaneously performing FFT-based spectral modulation in the frequency domain. These two modules operate synergistically with the backbone's native channel attention, forming a triple-granularity feature refinement pipeline. Extensive experiments on the UNC and BNU 3T-to-7T MRI datasets across T1w and T2w modalities demonstrate that DGCM-SSFA achieves strong structural fidelity, attaining an SSIM of 0.8431 on BNU T2w—approaching the best benchmark value of 0.8624—and 0.8100 on BNU T1w, while using substantially fewer parameters than Transformer-based alternatives such as ResViT (123.4M) and FS-RWKV (45.4M). These results validate that carefully designed multi-domain attention provides a practical and parameter-efficient solution for clinical MRI synthesis.

Index Terms—MRI synthesis, 3T-to-7T translation, multi-domain attention, frequency-aware modulation, sparse strip attention, compact network, medical image synthesis

I. INTRODUCTION

Magnetic resonance imaging at 7 Tesla (7T) represents the current gold standard for structural neuroimaging, offering an order-of-magnitude gain in signal-to-noise ratio and spatial resolution over conventional 3T scanners. This elevated tissue contrast enables the delineation of subcortical nuclei, cortical microarchitecture, and subtle white matter lesions that remain invisible at lower field strengths. Despite these compelling diagnostic advantages, 7T adoption is severely limited by hardware costs exceeding several million dollars, specialized site requirements, and stringent safety protocols—factors that collectively restrict access to a handful of elite research centers worldwide [1].

Synthesizing 7T-equivalent images from routine 3T acquisitions has therefore attracted substantial interest [2]–[4]. The task is to learn a mapping that recovers the high-resolution anatomical details latent in clinical scans, yet this mapping must capture fine-grained edge structures at tissue boundaries, long-range anatomical dependencies across entire brain regions, and subtle textural variations, which remains an open challenge.

Early approaches to this problem employed deep convolutional architectures [7]–[9] and generative adversarial formulations [10]–[12]. These methods exhibit a characteristic tradeoff: CNNs faithfully reconstruct local intensity patterns but fail to model dependencies beyond their limited receptive field, whereas GANs can hallucinate visually convincing textures at the cost of introducing spurious anatomical features that undermine diagnostic trustworthiness. More recent Transformer-based designs [13]–[15] address the global context deficit through self-attention, but their quadratic complexity forces aggressive downsampling that discards precisely the high-frequency details most critical for clinical interpretation. The latest generation of state space models [16], [17] partially resolves this tension by offering linear-complexity global modeling; however, they operate predominantly in the spatial domain and provide no explicit mechanism for frequency-selective feature refinement.

A deeper issue cuts across these paradigms. Anatomical structures in MRI span multiple scales and exhibit distinct signatures in both the spatial and frequency domains. Edge contours at tissue boundaries are best captured by local gradient operators, global intensity distributions across an entire slice are naturally modeled by long-range attention, and fine periodic textures are most compactly represented in the Fourier domain. Yet no existing cross-field synthesis framework integrates all three forms of attention—local edge-guided, global spatial, and frequency-domain—within a single unified architecture. This motivates the central premise of our work: that a carefully orchestrated synergy of complementary attention mechanisms can achieve competitive synthesis fidelity without the massive parameter counts of monolithic

*Corresponding author: eexie@qq.com. This work was supported by National Natural Science Foundation of China (62001184), the Projects of Educational Commission of Guangdong Province (2025ZDZX1038, 2025KTSCX49, 2023ZDZX1025), Graduate Education Innovation Program of Guangdong Province (2026JGXM_064), Huizhou University Independent Innovation Capability Enhancement Plan Project (HZU202535), College Students' Innovative Entrepreneurial Training Plan Program (202410577008, 202610577034).

Transformer or state space models.

We propose DGCM-SSFA, a compact multi-domain attention network built upon a U-Net Transformer backbone. Its first component (DGCM) is deployed at multiple encoder levels and combines an edge-aware spatial branch with a frequency-aware channel branch; the two branches gate each other [18]. The second component (SSFA) operates at the bottleneck, compressing the key-value token space from H×WH \times W to H+WH + W for near-linear global attention [19], with a parallel FFT branch that performs spectral modulation of the magnitude component. Both modules are detailed in Section III.

The principal contributions of this work are:

  1. A multi-domain attention architecture, DGCM-SSFA, that integrates dual-granularity cross-modulated feature enhancement and sparse strip frequency attention into a U-Net Transformer for 3T-to-7T MRI synthesis, operating at 11M parameters.

  2. The DGCM module, which unifies Sobel-structured edge priors, depthwise spectral estimation, and spatial-channel gating to amplify local anatomical detail.

  3. The SSFA module, which achieves global context modeling with near-linear complexity through strip-pooled attention and incorporates FFT-based spectral modulation for frequency-aware refinement.

  4. Extensive experiments on the UNC and BNU datasets across T1w and T2w modalities, demonstrating that DGCM-SSFA achieves strong structural fidelity—attaining an SSIM of 0.8431 on BNU T2w, approaching the best benchmark value of 0.8624 while using only 11M parameters, substantially fewer than Transformer-based alternatives.

References (37)