From Augmentation to Synthetic Evidence: Evaluating Generated Chest Radiographs at Dataset Intake

Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz

Abstract

A generated chest radiograph can be useful as declared augmentation, but the same image becomes unsupported evidence when submitted as the record of a real examination. We study this problem by separating three questions: whether an image passes an automated quality check, whether an origin classifier flags it as generated, and whether a trusted record supports the claimed acquisition. In our experiments, Qwen selects up to 20 images from pools of 1,000 existing Cheff-identified or SynthCheX candidates. A receiver evaluates quality with MedGemma and predicted origin with a classifier on frozen DINOv3 features. Quality-based selection raises quality passes from 12 to 19 of 20 for Cheff-identified images and from 8 to 17 for SynthCheX. We find no evidence that selection improves passage through both checks: no selected Cheff-identified image passes both, while uniform, quality, and quality-constrained surrogate selection produce 2, 1, and 2 SynthCheX passes. On unprocessed test images, the origin classifier flags 4,677 of 5,000 SynthCheX images, but it also misclassify 110 of 2,297 NIH (real) images and 568 of 957 genuine images from another collection as fake. Our results further show that JPEG compression reduces SynthCheX-versus-NIH AUROC from 0.987 to 0.841. Even without processing, 152 SynthCheX images pass both pixel checks. These checks can filter submissions, but they cannot verify an acquisition claim. We strongly advocate that source and intended use must be recorded and checked separately for admission of chest radiographs in medical datasets.

1 Introduction

Image generators can now produce high-resolution chest radiographs [9, 27]. Such images are useful when they are declared as synthetic, for example to augment training data. They cause a problem when they are submitted to a research dataset as records of real examinations. A receiving system may check whether an image has acceptable technical quality and whether a classifier considers it generated. Neither check shows that a real examination produced the image. A generated image may pass both checks, and its origin may be lost in later reuse. The dataset can then treat a generated image as a recorded examination without evidence that the examination took place.

We call such an image synthetic evidence: a generated image that is offered as evidence of a real examination without the support that this claim requires. The definition builds on earlier work on ground-truth drift and evidence grounding [1, 19]. Whether an image counts as synthetic evidence depends on the image, the claim made about it, and its intended use, because a generated image is not fraudulent in itself. Figure 1(a) shows an example from our study. This generated SynthCheX image passes our automated quality check, and our origin classifier does not flag it as generated. If it is submitted as a clinical acquisition, nothing supports that claim. If it is submitted as declared augmentation, the same pixels are acceptable.

The example shows that three questions must be kept apart. Quality: does the image meet the receiver's technical requirements? Predicted origin: does an image classifier label it as genuine or generated? Claim support: does the accompanying record support the claim that the image came from the stated acquisition, and is the declared use allowed? A pass on one question does not answer the others. An image can pass the first two, and the third stays open.

Earlier work measures the fidelity of generated radiographs, detects generated or edited medical images, and shows that compression and resizing can change detector behavior (Section 2). Can a submitter who chooses which generated images to send pass both checks more often than one who sends random images? In a controlled laboratory test, a submitter uses Qwen to select up to 20 images from pools of existing generated images, and a receiver applies a MedGemma quality check and an origin classifier built on DINOv3 features. A separate registry records the source and intended use. We find the following.

• Selection. Selecting by Qwen’s quality score increases

Figure

(a) Generated; passes both checks

(b) Genuine; passes quality, flagged as generated

Figure

(c) Genuine; fails quality, not flagged

(d) Generated; flagged as generated

Figure 1. One example for each outcome of the two checks, chosen after the analysis by a fixed hash rule. Images (a) and (d) are generated (SynthCheX), and (b) and (c) are genuine (NIH ChestX-ray14). Image (a) passes both checks, but its pixels do not support a claim that it records a clinical acquisition.

the number of images that pass the quality check, but we find no evidence that it increases the number that pass both the quality and origin checks.

• Processing. Image processing (JPEG compression and resizing) causes two separate problems for the origin classifier. Score shifts can invalidate a fixed threshold, which we call threshold drift. The classifier’s ranking can also deteriorate even after the threshold is reset, which we call ranking loss.

• Source shift. With the NIH-calibrated threshold unchanged, the primary classifier flags 568 of 957 genuine Open-I images.

Our contributions are (1) an intake test that keeps quality, predicted origin, and claim support separate, (2) measurements of how selection, processing, and a new genuine collection affect the quality and origin checks, and (3) a small registry experiment that records source and intended use apart from the pixels.