arXiv:2610.29267cs.CVOct 2026

Manuscript Offprint

arXiv:2610.29267

Clinical radar heart sounds with echocardiographic phenotypes of ventricular dysfunction and valvular disease

Jinye Li, Qingchao Chen

Abstract

Radar heart sounds capture cardiac mechanical activity without contact, while echocardiography characterizes ventricular and valvular function. Paired measurements connect these signals to structural heart disease, yet such data remain sparsely represented in public resources. Here we present 537 radar heart-sound recordings paired with one echocardiographic report for each of 162 patients. The cohort covers three overlapping phenotypes: left ventricular ejection fraction (LVEF) below 50%, regional wall-motion abnormality and at least moderate valvular regurgitation, present in 38, 43 and 39 patients, respectively. Original complex signals, processed radar heart sounds and temporal quality segmentation support signal-to-phenotype analysis. Technical validation retains 95.93% of signal duration and confirms reproducible waveform reconstruction. Patient-level five-fold evaluation achieves a mean outer-test AUROC of 0.770±0.1380.770 \pm 0.138 for reduced LVEF, identifying mechanical information associated with ventricular systolic dysfunction. This resource supports research linking non-contact cardiac mechanical signals to echocardiographic structural and functional phenotypes.

Keywords: radar heart sound; echocardiography; reduced LVEF; regional wall motion; valvular disease

1 Background & Summary

Structural heart disease, including ventricular dysfunction and valvular lesions, contributes to heart failure, disability and premature mortality, creating a substantial public-health burden[1, 2]. A US population-based study estimated moderate or severe valve disease in 2.5% of adults and 13.3% of those aged 75 years or older[2]. Echocardiography is a first-line imaging method and a clinical reference standard for characterizing cardiac structure and function. It quantifies left ventricular ejection fraction (LVEF), identifies regional wall-motion abnormalities and grades valvular regurgitation[3, 4], providing clinically defined phenotypes of ventricular and valvular dysfunction.

Public radar resources have advanced non-contact assessment of cardiac timing and rhythm through recordings paired with ECG and other physiological references[5, 6, 7]. Representative

∗^{*}This work was supported by grants from the National Natural Science Foundation of China (62571009).

†^{\dagger}Jinye Li is with the National Institute of Health Data Science, the Institute of Medical Technology, Peking University. He is also with the Beijing University of Posts and Telecommunications. Qingchao Chen is with the National Institute of Health Data Science, the Institute of Medical Technology, and the State Key Laboratory of General Artificial Intelligence, Peking University. Email: qingchao.chen@pku.edu.cn.

‡^{\ddagger}Corresponding author: Qingchao Chen.

collections include radar heart sounds with digital-stethoscope recordings, hemodynamic responses measured with impedance cardiography and blood pressure, and millimeter-wave signals referenced to ECG, respiration and pulse waveforms. These collections were acquired from healthy volunteers and do not pair radar recordings with echocardiographic labels of ventricular dysfunction or valve disease. Thus, the missing link is between radar-recorded cardiac mechanical activity and clinically characterized structural abnormalities. Addressing this gap requires patient recordings paired with measurements of systolic function, regional contraction and valvular regurgitation.

Here we present 537 radar heart-sound recordings paired with one retained echocardiographic report for each of 162 patients assessed in the Department of Cardiology at Peking University First Hospital. The cohort covers three nonexclusive phenotypes: LVEF below 50%, regional wall-motion abnormality and at least moderate regurgitation of any valve, present in 38, 43 and 39 patients, respectively. Repeated recordings within patients capture cardiac mechanical waveforms, while original complex signals, processed radar heart sounds (RHS) and temporal quality segmentation support analyses at both signal and patient levels.

The paired resource supports investigation of how cardiac mechanical waveforms relate to ventricular systolic function, regional wall motion and valvular abnormalities. Technical validation retains 95.93% of nominal signal duration and confirms reconstruction of processed RHS from original complex samples. Patient-level five-fold evaluation achieves a mean outer-test AUROC of 0.770±0.1380.770 \pm 0.138 for reduced LVEF, demonstrating identifiable mechanical information associated with systolic dysfunction. Together, clinical phenotyping, waveform traceability and patient-level evaluation provide a foundation for developing non-contact cardiac mechanical markers and investigating overlapping structural and functional abnormalities.