arXiv:2610.29272cs.CVOct 2026

Manuscript Offprint

arXiv:2610.29272

Certified Abstention for Provably-Unidentifiable Index-Phase Recovery in Image Registration

Dinh Tuan Nguyen, Trong Nhan Nguyen, Vu Nguyen Minh Hung, Tien Minh Khoi Nguyen, Jaeyeop Choi, Sudip Mondal, Jae Sung Ahn, Junghwan Oh

Dinh Tuan Nguyen, Trong Nhan Nguyen, Vu Nguyen Minh Hung, Tien Minh Khoi Nguyen, Jaeyeop Choi, Sudip Mondal, Jae Sung Ahn, and Junghwan Oh

Abstract—Image registration underpins measurement across scanning, camera, and microscopy imaging, yet a fundamental question is rarely posed: when is the sample-to-position map recoverable at all, and when does any estimator that reports a position necessarily fabricate one? We show that in reference-perturbed sampled imaging, where samples are localized through a perturbed reference, position fidelity (where samples land) and phase fidelity (which reference index becomes each block's origin) are logically independent: no policy acting on position information alone can guarantee phase fidelity. We derive a tight resolution threshold separating recoverable from provably-unidentifiable registration, and a recovery framework that certifies identifiable regions—recovering them exactly—while abstaining on provably-unidentifiable regions rather than hallucinating structure. On a deployed scanning system we measure a direction-bimodal registration offset consistent with the theory. Against classical and learned restoration baselines, certificate-free offset estimators fabricate structure on the unidentifiable regime, whereas the certified method abstains rather than fabricating. Finally, the certified-abstention mechanism carries across scanning, rolling-shutter, and cryo-electron-microscopy imaging—declining rather than fabricating on the regime it flags—though how completely it abstains and how tightly it bounds kept-region risk stay modality-specific (at extreme SNR the cryo-EM certificate abstains only partially): a structural-versus-statistical boundary in registration reliability.

Index Terms—Image registration, recoverability, identifiability, certified abstention, selective prediction, conformal risk control, hallucination, rolling shutter, cryo-EM multireference alignment, triggered acquisition.

I. INTRODUCTION

Correcting a scanned image for geometric distortion is an image registration and restoration task: a per-line shift is estimated and inverted so that each pixel is returned to its true grid position. This paper studies the reliability of that task under a corruption that is common in triggered scanning yet largely unexamined in registration theory—an unknown integer, per-line index shift. We prove the correction problem has a regime that is provably unidentifiable: no estimator, learned or classical, can recover the shift from the image, and any estimator that nonetheless reports one fabricates structure. We therefore equip the restorer with a distribution-free certificate that decides, per line, when to recover and when to abstain. The question is timely: as learned restoration methods increasingly synthesize confident but unsupported structure [1], a provable certificate for when registration is unrecoverable—so a pipeline abstains rather than fabricates—addresses a reliability concern that empirical restorers, by construction, cannot settle. Read this way, the results below are limits of image registration under this corruption model—when the per-line shift is recoverable, when it is provably not, and how to certify the difference—alongside the acquisition-side conditions (a separation, an impossibility, and a tight timing threshold) under which the corruption arises and can be prevented.

The shift originates at acquisition. A probe or beam is rastered across a static part along a fast axis; samples are triggered at positions locked to an absolute encoder grid, and a slow axis steps between traversals, so absolute-position triggering fixes where samples land but not which sample becomes column 0 of each line. The stored pixel array is read as a metric map—the sample at array index (i,j)(i,j) is taken to have been captured at grid position p(i,j)p(i,j)—so a flagged defect occupies a known physical location and finer trigger pitch is believed to yield finer spatial fidelity. We prove this belief is incomplete and measure the failure on a deployed system: on a position-triggered laser-ultrasound C-scanner the per-line index origin is displaced by a rigid, direction-dependent offset that swings 17.3 columns between forward and reverse sweeps, verified from hardware timestamps—misplacing every feature in a line, a defect included, while the image still looks sharp. The prevention is an origin-coupled synchronization reference, which we prove necessary and sufficient to restore index fidelity.

Grid-locked sampling guarantees that each sample lands on a grid position within its block (the fast-axis traversal), but it does not guarantee that the block's samples are indexed consistently across blocks. Because acquisition proceeds block by block and the hardware must re-initialize between blocks, the index origin of each block—which physical grid crossing becomes “column 0”—is set by an asynchronous re-initialization event, not by position. Absolute position fidelity

D. T. Nguyen, T. N. Nguyen, V. N. M. Hung, T. M. K. Nguyen, and J. Oh are with the Industry 4.0 Convergence Bionics Engineering, Department of Biomedical Engineering, Pukyong National University, Busan 48513, Republic of Korea.

J. Choi, S. Mondal, and J. S. Ahn are with the Smart Gym-Based Translational Research Center for Active Senior's Healthcare, Pukyong National University, Busan 48513, Republic of Korea. S. Mondal is also with the Digital Healthcare Research Center, Institute of Information Technology and Convergence, Pukyong National University, Busan 48513, Republic of Korea.

J. Oh is also with Ohlabs Corp., Busan, Republic of Korea.

Corresponding authors: Jae Sung Ahn (e-mail: jsahn@pknu.ac.kr) and Junghwan Oh (e-mail: jungoh@pknu.ac.kr).

This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) under Grant 2022R1A5A8023404.

Competing interests: J. Oh is affiliated with Ohlabs Corp.; this is disclosed for transparency. The other authors declare no competing interests.

and consistent phase (index) fidelity are distinct guarantees, and the second is not implied by the first. (Throughout, “phase” denotes this discrete index/origin phase of a block—which grid crossing is stored as column 0—not RF or signal phase.)

a) Scope (a registration/restoration problem with special structure; phase, not warp).: We pose grid fidelity as an image registration and restoration problem whose corruption has a special structure—a per-line integer index shift with a provably-unidentifiable band. The shift originates at acquisition (an honest acknowledgement, not the subject): the object we analyze and correct is the formed image, and the estimators and certificate below are image-processing methods operating on it. We stress two scoping decisions. First, our notion of spatial fidelity is geometric/index fidelity—the correspondence between array indices and grid positions—not the perceptual/information fidelity of quality metrics such as VIF [2]; the two are unrelated. Second, we deliberately confine the theory to inter-block phase fidelity (the discrete index origin of each block) and bracket out continuous intra-block distortion (e.g. within-traversal warp from speed variation). The latter is a separate phenomenon with a separate analysis; mixing the two obscures both.

b) Generality.: The object of study is a grid-locked block-sequential sampler: any acquisition that (a) samples a static field along a fast axis at positions locked to an absolute grid, (b) acquires in blocks (one per traversal/line), and (c) re-initializes between blocks with a nonzero latency. This abstracts a wide range of modalities—scanning electron and transmission electron microscopy with flyback, atomic-force/scanning-probe line scanning with re-trace, push-broom and line-scan cameras, optical-coherence B-scan stacking, and ultrasonic/photoacoustic raster C-scanning. The results below are stated for this class; no result depends on a particular instrument.

References (32)