arXiv:2610.29367cs.NEOct 2026

Manuscript Offprint

arXiv:2610.29367

Probing Spatial and Spectral Grounding in EEG Foundation Models

Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou

ABSTRACT

EEG foundation models are advancing at an unprecedented pace, yet their evaluation is driven by downstream accuracy, which reveals little about whether their predictions rely on physiologically interpretable signal structure. We introduce a set of perturbation probes in two grounding axes: spatial grounding in channel identity and topographic locality, and spectral grounding in oscillatory content and waveform morphology. We apply these probes to five published EEG foundation models across motor-imagery and seizure recordings. Our experiments reveal differences in both representational sensitivity and downstream reliance. Electrode identity may be encoded without influencing downstream classification: permuting LaBraM's positional codes heavily displaced its embeddings yet reduced motor-imagery accuracy by only 1.2 points, while spectral details may be discriminable without producing specific responses to simulated clinical markers, as only REVE exceeded a spectral baseline on this task. These dissociations are hidden in common benchmarks, demonstrating how grounding probes can complement performance-based evaluation by revealing what EEG foundation models encode and what their predictions depend on.

Index Terms— Electroencephalography, EEG foundation models, perturbation, spatial grounding, spectral grounding

1. INTRODUCTION

Electroencephalography (EEG) offers a non-invasive, low-cost measure of brain activity. EEG foundation models (EEG-FMs), trained on thousands of unlabeled recordings, have achieved state-of-the-art performance across domains ranging from motor imagery and sleep staging to emotion recognition and clinical event detection [1, 2, 3]. However, task performance alone does not guarantee that a model captures properties used in expert EEG interpretation. Such interpretation often relies on spatial context across electrodes and waveform characteristics when spectral information alone is insufficient. For example, clinicians distinguish muscle contamination from epileptiform activity using the spatial distribution and morphology of a discharge, despite overlapping spectral properties and the dominance of muscle activity in scalp power [4]. More generally, electrode location carries physiologically meaningful information [5, 6], while clinically relevant EEG phenomena are often defined by waveform morphology [7]. We refer to these complementary requirements as spatial and spectral grounding, where spectral grounding encompasses sensitivity not only to oscillatory power, but also to phase-dependent temporal structure and waveform morphology.

Such grounding may not be apparent from conventional downstream benchmarks: accuracy indicates how often an adapted model is correct, but not which signal properties support its predictions. This ambiguity is particularly relevant to EEG because recordings contain limited high-level semantic structure and are affected by environmental noise, device-specific artifacts, and between-subject variability. Consequently, competitive performance may be achieved partly through artifact-related shortcuts. Conversely, a representation may preserve meaningful spatial or spectro-temporal information that a downstream prediction head does not use. We therefore ask three separate questions: Can the architecture access a signal property? Is that property encoded in the learned representation? And do downstream predictions rely on it?

We investigate these distinctions through controlled perturbation-response experiments. To evaluate spatial grounding, we intervene on channel-to-location assignments by independently manipulating electrode identity, channel order, and learned positional encoding. Spectral probes test whether models distinguish recordings from surrogates that preserve power spectra while disrupting phase-dependent temporal structure, and whether their representations decode injected oscillations across canonical frequency bands. We further test whether representational sensitivity affects downstream predictions. We applied this framework to five EEG-FMs: BIOT [8], LaBraM [9], CBraMod [1], CSBrain [10], and REVE [2], and relate their observed dissociations to differences in model architecture and pre-training. Our contributions are as follows:

• We introduce spatial interventions that disentangle electrode identity and positional encoding, and characterize distance-dependent cross-channel influence across model depth.

• We introduce spectral interventions that evaluate sensitivity to phase-dependent structure beyond spectral power and to oscillatory activity across canonical frequency bands, calibrated against handcrafted, non-learned baselines.

• We show that architectural access to signal information, its preservation in learned representations, and its use in downstream predictions are distinct properties that cannot be inferred from performance benchmarks alone.

Evaluation Studies: Prior evaluation studies have found inconsistent gains over lighter supervised decoders: fine-tuned on memory and sleep benchmarks, EEG-FMs improve over these baselines by around 1% while carrying millions of additional parameters [11], whereas when the labels are scarce they do not outperform lighter decoders [12, 13]. Evaluation has accordingly moved past accuracy metrics. Benchmarking EEG-FMs on a suite of eight datasets yielded attribution maps that stay spatially stable under perturbation while the predictions degrade [14]. On the spectral side, a recent qualitative study injected synthetic oscillations and found that embeddings were dominated by the aperiodic power spectrum, with the oscillatory components increasingly underrepresented toward higher frequencies [15]. It remains unclear whether representations are grounded in interpretable EEG properties, such as electrode location or waveform structure beyond spectral power.

This work was done during an internship at Microsoft Research.

Foundation models for EEG. EEG-FMs pretrain encoders on large unlabeled corpora and adapt them to diverse downstream tasks [16], differing in input tokenization and in how they encode electrode topology. We select 5 publicly released models that jointly cover the main design choices. BIOT [8] tokenizes a fixed bipolar montage as STFT magnitudes indexed by learned slot tokens. LaBraM [9] trains a quantization-based tokenizer whose targets are the Fourier amplitude and phase, then re-trains the encoder on masked code prediction. CBraMod [1] adds a magnitude-spectrum pathway and applies a depthwise convolution over the channel axis, consuming order but not electrode identity. CSBrain [10] shares that magnitude pathway while grouping electrodes into anatomical regions, thus attending over coarse topography. Finally, REVE [2] embeds raw temporal patches and conditions attention directly on continuous 3D electrode coordinates. The models further differ in size, ranging from 3.2M parameters for BIOT to 69M for REVE, and are trained on corpora ranging from a few to thousands of hours.

References (23)