arXiv:2610.29515cs.LGOct 2026

Manuscript Offprint

arXiv:2610.29515

BRIDGE: An Acceptance Gate to Block False Improvements in Model Updates, with a Retrospective Clinical Evaluation

Dwi Sunaryono

This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.

Preprint submitted to IEEE Access, October 2026

BRIDGE: An Acceptance Gate to Block False Improvements in Model Updates, with a Retrospective Clinical Evaluation

DWI SUNARYONO 1^{1}

Department of Informatics, Faculty of Intelligent Electrical and Informatics Technology, Institut Teknologi Sepuluh Nopember, Surabaya 60111, Indonesia

Corresponding author: Dwi Sunaryono (e-mail: dwi@its.ac.id).

This research is funded by the Indonesian Endowment Fund for Education (LPDP) on behalf of the Indonesian Ministry of Higher Education, Science, and Technology, and managed under the EQUITY Program (Contract No. 4299/B3/DT.03.08/2025 and No. 3029/PKS/ITS/2025), Directorate of Research and Community Service Institut Teknologi Sepuluh Nopember Ministry of Higher Education, Science, and Technology in accordance with the Implementation Agreement of the Strategic Research Grant (SRG) Assigned Research Program Institut Teknologi Sepuluh Nopember Fund for the Year 2026 Researcher Contract Number: 1669/PKS/ITS/2026, dated February 10, 2026.

ABSTRACT

Models are updated repeatedly, and an update that looks better on validation data but not on new data is a false improvement that can misguide clinical decisions. The naive rule accepts every positive validation gain and is optimistic when the same data choose and judge the update. BRIDGE is a model-agnostic acceptance gate that decides each update from predictions and the available labels, with fixed settings. Each fold of the data judges the update chosen on the other folds (cross-fitting) to reduce selection bias; acceptance requires the gain's lower bootstrap bound to exceed a margin. The four settings are (A) 11 new datasets, (B) synthetic tasks, (C) 12 retrospective clinical tasks, and (D) 39 supporting datasets. The false-improvement rate falls from 19.1% (naive) to 1.1% (BRIDGE) in (A), 20.7% to 1.7% (B), 20.0% to 0% (C), and 12.5% to 0.5% (D); every 95% confidence interval of the reduction over datasets or tasks excludes zero (not over the clinical sources). An equal-size random draw from the naive acceptances contains more false improvements in (A)–(E) (post hoc, p < 0.001). On the OpenML collection (E) of 14 new datasets, the false-improvement rate falls from 25.6% to 1.0%. BRIDGE removes 97% to 100% of the false improvements that the naive rule accepts, and its mean gain per deployed update is 1.8 to 3.1 times the naive rule's. The 95% upper bound on the false-improvement rate is below 5.5%: formal in (B) for independent tasks (3.56%), and conditional on the real data tested (0.33% to 5.40%).

INDEX TERMS Acceptance gate, bootstrap, clinical prediction, cross-fitting, decision algorithm, false improvement, model selection, model updating, risk control

arXiv:2610.29515

References (87)