arXiv:2610.29616cs.CVOct 2026

Manuscript Offprint

arXiv:2610.29616

An interpretable deep learning method for early hepatocellular carcinoma diagnosis on multiphase CT

Emma Sarfati, Alexandre Bône, Pietro Gori, Sisi Yang, Marc-Michel Rohé, François Nicolas, Jeong-Min Lee, Jeong Hee Yoon, Maxime Ronot, Isabelle Bloch, Christophe Aubé

Emma Sarfati, PhD 1,2^{1,2}

Alexandre Bône, PhD 1,∗^{1,*}

Pietro Gori, PhD 2^{2}

Sisi Yang, MD 1,3,4^{1,3,4}

Marc-Michel Rohé, PhD 1^{1}

François Nicolas, PhD 1^{1}

Jeong-Min Lee, MD 5^{5}

Jeong Hee Yoon, MD 5^{5}

Maxime Ronot, MD, PhD 6,7^{6,7}

Isabelle Bloch, PhD 2,8^{2,8}

Christophe Aubé, MD, PhD 9,10^{9,10}

1^{1} Guerbet Research, Villepinte, France

2^{2} LTCI, Télécom Paris, Institut Polytechnique de Paris, Saclay, France

3^{3} MAP5 (UMR 8145), Université Paris Cité, 45 rue des Saints-Pères, Paris, France

4^{4} Radiology B Department, Hôpital Cochin, 27 Rue du Faubourg Saint-Jacques, Paris, France

5^{5} Seoul National University Hospital, Department of Radiology, Seoul, Korea

6^{6} Service de Radiologie, Hôpital Beaujon, APHP-Nord, Clichy, France

7^{7} Université Paris Cité, CRI, INSERM UMR 1149, Paris, France

8^{8} Sorbonne Université, CNRS, LIP6, Paris, France

9^{9} Département de Radiologie CHU Angers, Angers 49933, France

10^{10} Laboratoire HIFIH, Université d'Angers, Angers, France

Guerbet Research, 15 Rue des Vanesses, 93420 Villepinte, France.

Keywords: hepatocellular carcinoma; LI-RADS; deep learning; radiomics; computed tomography; interpretable artificial intelligence.

ABSTRACT

Early diagnosis of hepatocellular carcinoma is critical to preserve access to curative treatment options. The Liver Imaging Reporting and Data System (LI-RADS) provides a standardized framework for non-invasive diagnosis on multiphase computed tomography, based on major visual imaging features. However, these features may be difficult to assess consistently, particularly in small liver lesions. We developed dLI-RADS, an interpretable artificial intelligence method designed to estimate the probability of hepatocellular carcinoma from multiphase computed tomography images of manually segmented liver lesions, while remaining aligned with LI-RADS-related imaging concepts. dLI-RADS combines neural network-derived predictions with handcrafted quantitative imaging measurements reflecting LI-RADS major features and integrates these inputs using logistic regression. In this multicenter retrospective study, patients with multiphase computed tomography and at least one liver lesion were included, while lesions larger than 40 mm were excluded. Histology served as the reference standard for hepatocellular carcinoma, and a composite reference standard was used for non-hepatocellular carcinoma lesions. The lesion-level accuracy of dLI-RADS and LI-RADS were compared on the internal evaluation set using 10,000-repetition bootstrap non-inferiority tests, with 5% margins and significance levels. On the external test set, sensitivities were similarly compared. A total of 143 (61 years ±9, 125 men), 62 (61y±10, 49 men), and 133 (59y±10, 103 men) patients with 196, 84, and 171 lesions (mean diameter 17.7, 18.3, and 21.8 millimeters) were respectively included in the training, internal and external evaluation sets. dLI-RADS was non-inferior to LI-RADS for lesion-level accuracy in the internal evaluation set, achieving 80% accuracy compared with 74% for LI-RADS (p = 0.04). On the external evaluation set, dLI-RADS achieved a sensitivity of 93% compared with 78% for LI-RADS (non-inferiority p < 0.001). On this same set, dLI-RADS also achieved 74% specificity, 86% accuracy, and an AUC of 84%. Because LI-RADS features were unavailable for non-HCC lesions, only sensitivity could be directly compared between dLI-RADS and LI-RADS. These findings suggest that dLI-RADS may provide interpretable decision support for hepatocellular carcinoma diagnosis on multiphase computed tomography, particularly for small liver lesions.

Introduction

Accurate and timely diagnosis of hepatocellular carcinoma (HCC) is essential to preserve treatment options [1]. Since its original introduction to standardize the interpretation of multi-phase imaging and provide a common probabilistic language for clinical decision-making, the Liver Imaging Reporting and Data System (LI-RADS) v2018 [2] has become a reference methodology for HCC diagnosis [3,4], with evidence of high accuracy levels [5]. Nonetheless, non-invasive HCC diagnosis remains challenging and subject to inter-reader variability, particularly on CT where major features are more difficult to assess than on MRI [6–8].

In parallel to these efforts to standardize the usage of long-known imaging characteristics of HCC, novel quantitative markers were proposed in “radiomics” studies [9,10] where pre-determined libraries of handcrafted features are mined to identify promising diagnostic or prognostic elements, with the intent to automate, complement or even surpass human image analysis. Going a step further in the terms of abstraction, deep learning methods were also proposed to extract purely data-driven HCC features, reporting promising diagnostic performance levels [11–20]. However, a common fundamental limitation of these studies is their focus on large-size HCC lesions, i.e. with average diameters larger than 30 mm, while there is a strong interest in diagnosing smaller early-stage HCC nodules, which are much more difficult to correctly characterize [8,21,22]. These approaches are also limited in their explainability: HCC presence probabilities are typically computed without any details about the reasoning process, or at best with spatial activation maps [14] which allow the user to visually verify that the correct region of the image (i.e. the tumor) contributed to the prediction. This contrasts with handcrafted radiomics that are intrinsically interpretable.

In this study, we propose and evaluate dLI-RADS, a deep learning method for lesion-level diagnosis of early-stage HCC from manually segmented multiphase CT lesions. Methodologically, dLI-RADS relies on a combination of deep and handcrafted features to strike a balance between clinical performance and model explainability. This method was specifically designed to perform HCC diagnosis for challenging small-size liver lesions, and its performance was compared to LI-RADS using non-inferiority tests in two independent cohorts of patients from Europe and Asia respectively.