D-Pingmesh: Dynamic Probing and Fault Localization for Reconfigurable Datacenter Networks

Yunze Wei, Kaicheng Yang, Xiaohui Xie, Dunkai Mao, Peiying Tao, Yikai Zhao, Bolong Cui, Chen Sun, Bingyang Liu, Kun Tan, Kai Chen, Yong Cui

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Pingmesh monitors datacenter networks through periodic pings between servers. In reconfigurable datacenter networks, topology engineering (TPE) and traffic engineering (TE) make uniform server-pair probing inefficient: a pinglist wastes budget retesting common paths while missing low-probability interfaces. Frequent control-plane updates further require rapid pinglist refresh, and cause path ambiguity at control-plane boundaries for fault localization. We present D-Pingmesh, a probing and fault-localization system co-designed with the TPE/TE control plane. Its control-plane-aware generator builds task-efficient pinglists by greedily admitting probes with high interface coverage under the current TPE/TE snapshot. An incremental replay-and-repair mechanism updates pinglists across reconfigurations rather than recomputing from scratch. At control-plane boundaries, a Rho-EM localizer jointly infers per-task old/new-path mixture weights and the fault set through EM-style iteration. We evaluate D-Pingmesh on an 8-pod reconfigurable topology under dynamic TPE/TE. At a 0.99 coverage target, D-Pingmesh uses 17.7×17.7\times fewer tasks than Pingmesh and generates each pinglist about 5.1×5.1\times faster than RD-Probe. In ns-3 simulation, boundary-aware localization improves micro F1 from 0.871 to 0.953 over the deTector PLL baseline. A testbed deployment demonstrates second-scale fault localization with low host overhead. These results demonstrate that D-Pingmesh is practical for reconfigurable datacenter networks with control-plane-aware monitoring.

CCS Concepts: • Networks → Data center networks; Network monitoring.

Keywords: Reconfigurable datacenter networks, Active probing, Fault localization

*Co-corresponding authors: Chen Sun (sunchen48@huawei.com) and Yong Cui (cuiyong@tsinghua.edu.cn).

†Kun Tan is an independent researcher.

Figure

This work is licensed under a Creative Commons Attribution 4.0 International License.

SIGOPS ATC 2026, Hong Kong, China

© 2026 Copyright held by the owner/author(s).

ACM ISBN 979-8-4007-2818-1/2026/11

https://doi.org/10.1145/3828523.3857045

ACM Reference Format:

Yunze Wei, Kaicheng Yang, Xiaohui Xie, Dunkai Mao, Peiying Tao, Yikai Zhao, Bolong Cui, Chen Sun, Bingyang Liu, Kun Tan, Kai Chen, and Yong Cui. 2026. D-Pingmesh: Dynamic Probing and Fault Localization for Reconfigurable Datacenter Networks. In The 2026 ACM SIGOPS Annual Technical Conference (SIGOPS ATC 2026), November 15–18, 2026, Hong Kong, China. ACM, New York, NY, USA, 15 pages. https://doi.org/10.1145/3828523.3857045

1 Introduction

Network faults remain a critical source of availability incidents in modern datacenters. Even when per-component failure rates appear small, they become operationally significant at cluster scale: measurements of Google’s TPUv4 deployment report average daily failure rates of 0.005% for interconnect cables and 0.04% for optical circuit switches (OCSes) [37]. In clusters with thousands to tens of thousands of devices, such rates make online network testing and accurate fault localization necessary rather than optional.

Active probing remains one of the most practical mechanisms for this purpose. By sending probe traffic between servers, it provides direct end-to-end evidence about reachability and latency without requiring pervasive switch instrumentation or changes to production applications. Pingmesh established this model for large datacenter networks [11]. Subsequent systems have improved probe placement, coverage guarantees, service awareness, and fault localization for different settings [9, 12, 21, 24, 30]. These systems, however, largely assume that the network state used to plan probes remains stable within a measurement window: once a task is selected, its observations can be associated with a small set of expected paths.

This assumption breaks down in modern datacenters, which increasingly treat the network as a reconfigurable resource driven by two architectural control-plane mechanisms. Topology engineering (TPE) reconfigures the OCS to align connectivity with traffic demand [3, 5, 16, 20, 25, 29]. Traffic engineering (TE) adjusts weighted forwarding splits over that topology to accommodate shorter-term demand fluctuations [22, 23, 33]. These mechanisms can change which physical interfaces a given packet traverses at sub-minute to minute timescales [23]. AI training and inference clusters further reinforce this trend: their recurring communication patterns make TPE and TE especially effective at adapting the network to demand [14, 31].

However, probing systems such as Pingmesh were designed and have evolved independently of these control loops. They treat the network as a static underlay and plan probes in terms of server pairs, without consuming the current TPE/TE state as input. Consider a TE update that changes the forwarding weights between two pods: a probe task between the same two servers can resolve to different interfaces before and after the update. A monitor seeing only the server pair cannot determine whether a loss observation belongs to the old path or the new one. Across our measurement traces, 15–28% of probe tasks change their resolved path across a single TE update on average. The server pair, which traditional probing uses as the stable unit of diagnosis, loses its anchoring power once TE remaps the same pair to different interfaces.

A single timely detection may suffice for a persistent hard failure, but diagnosing gray packet loss requires repeated observations, and transient faults may disappear before the next stable window. These observation requirements motivate continuous probing that gathers sufficient evidence while faults are present and correctly interprets observations across reconfigurations.

Meeting these requirements calls for co-designing network monitoring with the TPE/TE control plane to overcome three challenges. First, TPE and TE induce asymmetry in interface hit probability. Under uniform server-pair selection, probes concentrate on high-probability interfaces and may starve others in the same network state. Second, TPE/TE updates introduce dynamics: a pinglist optimized for one snapshot may lose coverage after the next update, yet regenerating from scratch discards the coverage contribution of tasks that remain valid. Third, TPE/TE transitions create boundary inconsistency for diagnosis. Because TE updates deploy at pod granularity rather than atomically, different parts of the network transiently operate under different TE snapshots, so probe observations in the same probe window may correspond to different path states.

To address these challenges, we present D-Pingmesh, a probing and fault-localization system co-designed with the TPE/TE control plane. D-Pingmesh consumes current topology and TPE/TE snapshots, and uses reconfiguration timing to schedule probe windows at ping agents. For each candidate ping task, D-Pingmesh determines the interfaces that the task can observe under the current control-plane state and uses this information for both task planning and fault interpretation.

D-Pingmesh tackles the asymmetry challenge by formulating probe generation as an interface multicover problem under the current control-plane state. It scores pod pairs by their expected coverage contribution, samples candidate five-tuples from high-scoring pairs, and greedily admits tasks that advance the multicover objective. To handle TPE/TE dynamics, D-Pingmesh maintains this multicover solution incrementally: it replays the previous pinglist under the new

Figure

(a) A reconfigurable datacenter network model with OCSes.

Figure

(b) OCS abstraction.

Figure 1. OCS-based reconfigurable datacenter network.

snapshot, repairs residual coverage deficits, and prunes redundant tasks without reducing achieved coverage.

D-Pingmesh further addresses boundary inconsistency with Rho-EM, a fault localizer that considers both pre- and post-update path hypotheses. For aggregate probe results collected around a TE transition, Rho-EM assigns each task a path-mixture weight ρq\rho_{q}, evaluates candidate faulty links through a likelihood model that estimates per-interface loss rates, covering both complete link failures and gray packet-loss faults, and refines the weights and fault set jointly via EM-style iteration.

We evaluate D-Pingmesh on an 8-pod, 2,048-server OCS-based topology, comparing it with Pingmesh, deTector, and RD-Probe. Our evaluation includes TE updates and controlled TPE transitions, with a separate scalability study extending to 64 pods and 16,384 servers. At a 0.99 coverage target, D-Pingmesh reduces task count by 17.7×17.7\times over Pingmesh and generation time by an estimated 5.1×5.1\times over RD-Probe. In ns-3 simulation, Rho-EM improves F1 score of fault localization from 0.871 with deTector PLL to 0.953 across varying fault counts and loss rates. A testbed prototype further shows that D-Pingmesh localizes faults at second scale with low host overhead.

We make the following contributions:

• We identify three monitoring challenges in reconfigurable datacenter networks driven by TPE and TE: interface-hit asymmetry, coverage changes across snapshots, and boundary inconsistency.

• We design a control-plane-aware probe generation and incremental update approach. It scores pod pairs by their expected coverage contribution under the current TPE/TE snapshot, and incrementally repairs pinglists across TPE/TE changes.

• We design Rho-EM, a boundary-aware fault localizer that jointly refines per-task old/new-path probabilities and a fault set via EM-style iteration, supporting both link failures and gray packet-loss faults.

• We evaluate D-Pingmesh under dynamic TPE/TE inputs. It achieves target coverage with fewer tasks and lower generation time than Pingmesh, deTector, and RD-Probe. A testbed prototype demonstrates second-scale fault localization with low host overhead.

Table 1. Comparison of monitoring systems from the perspective of reconfigurable datacenter networks.

Monitoring RequirementPingmesh [11]deTector [24]RD-Probe [9]D-Pingmesh
Probe-efficient coverage under current TPE/TE state×△△✓
Low-cost update after reconfiguration××△✓
Robust diagnosis at reconfiguration boundaries×××✓

√: supported, △: partial support, ×: not supported.