arXiv:2610.27518cs.AIOct 2026

Manuscript Offprint

arXiv:2610.27518

When Health Assistants Agree Too Readily: A Benchmark of Time-Critical Self-Diagnosis

Marilyn Zhang, Tianfeng Chen, Patricia M Pechter, Mark E. Whiting

Abstract

Every day, more than 40 million people ask ChatGPT a health question, such as whether laptop posture explains a stiff neck and days of pounding headache. Posture is plausible, but meningitis is a time-critical possibility. We introduce SELFDX, a paired benchmark for whether models have the appropriate response behavior, a form of epistemic independence, in health questions where misplaced agreement with the user's self-diagnosis could delay urgent or emergency care. Each of 100 pairs contrasts a caution case, where a serious alternative remains possible, with an agreement case, where the user supplies evidence that rules out the alternative and it is safe for the model to agree. We find across 27 frontier models that they tend to inappropriately agree with the user's self-diagnosis in cases that require caution. Even the best current-generation model reaches only a 77.0% appropriate caution rate on time-critical condition cases. To address this gap, we experiment with three prompt variants that increase appropriate caution but reduce appropriate agreement by 9–35%, indicating excessive caution. In contrast, supervised fine-tuning on 128 balanced examples improves both rates together across three runs. We recommend post-training to improve appropriate caution without making models cautious on every case, with paired evaluation to verify both response behaviors.

1 Introduction

A user asks whether laptop posture explains a stiff neck and days of pounding headache. Posture is plausible, but meningitis is a time-critical possibility, and an appropriate response cautions the user rather than agreeing with the self-diagnosis. Clinical practice documents the same failure. Croskerry [2002] warns that “physicians should always be wary when a patient begins the exchange by volunteering his or her own diagnosis,” and names the resulting bias diagnosis momentum, in which an inherited label discourages consideration of alternatives. Case series identify premature closure as the most common contributor to diagnostic error and implicate cognitive factors more often than gaps in knowledge [Graber et al., 2005]. A benchmark that scores whether a model can name the correct diagnosis therefore measures knowledge, not whether the model agrees with a self-diagnosis the user has already proposed.

Inappropriate agreement matters because people already take such questions to chatbots. According to OpenAI, more than 40 million people ask ChatGPT a health question every day, and roughly seven in ten of those conversations occur outside clinical hours [OpenAI, 2026]. In one survey, 42% of adults who asked a chatbot about physical health did not later consult a provider [Kaiser Family Foundation, 2026]. The chatbot may therefore be the last source a user consults before deciding whether to seek care. In 158,083 symptom-checker encounters, 32% of users reduced their intended level of care and 4% increased it. The study could not determine whether those changes were appropriate [Winn et al., 2019]. A review of 14 randomized trials also found that reassurance reduced subsequent primary-care visits without reducing worry, anxiety or symptom persistence [Rolfe and Burton, 2013].

40th Conference on Neural Information Processing Systems (NeurIPS 2026). Workshop: The Third Workshop on GenAI for Health: Agentic Systems, Clinical Trust, and Future Potential.

We introduce SELFDX, a benchmark of 100 matched pairs of questions framed to invite agreement with the user, to test a model's epistemic independence in a time-critical health setting. In each pair, the caution case leaves a serious alternative possible. The agreement case repeats the same self-diagnosis and adds the evidence that rules that alternative out, so agreement is then warranted. The pairs cover two common types of health questions, one where the user attributes a symptom to a benign condition and one where the user attributes it to a medication they take. We choose time-critical situations, so that inappropriate agreement carries a cost, delaying the user from time-sensitive care. Our contributions are as follows.

  1. SELFDX, a benchmark of 100 matched pairs, with cases and grading criteria screened by physician review ( §3\S3).

  2. An evaluation of 27 frontier models on SELFDX, finding that models tend to inappropriately agree with the user's self-diagnosis in cases that require caution. Even the best current-generation model reaches only a 77.0% appropriate caution rate on condition cases, an appropriate caution rate is the lowest of the four for 24 of the 27 models, and appropriate caution is lower on condition cases than on medication cases ( §4§4).

  3. Two interventions aimed at improving model behavior for appropriate caution and appropriate agreement together in self-diagnosis cases. Three prompt variants increase appropriate caution but reduce appropriate agreement by 9–35%, indicating excessive caution. In contrast, supervised fine-tuning on 128 balanced examples improves both rates together across three runs ( §5§5).

References (34)