arXiv:2610.27739cs.CROct 2026

Manuscript Offprint

arXiv:2610.27739

Make the Adversary Spend More Energy: Generative Deception against Language-Model Attackers in Critical Infrastructure

Vlad Mihal, Hosam Alamleh, Alessandro Cantelli-Forti

Abstract

Language-model attackers consume computational resources as they explore and interact with a target, creating an opportunity for cyber deception to impose costs. Whether such engagements favor the defender requires measuring both sides. We evaluate an autonomous language-model attacker against a decoy that uses a defending language model to analyze attacker commands and select defensive responses. Across 330 sessions, eight model pairs, two attacker profiles and three counter-injection levels, both sides run on identical GPUs and their energy is measured above idle. With runtime thinking disabled, the attacker-to-defender energy ratio has a 95% interval above one in 41 of 48 configurations under an allocation excluding attacker diagnostic calls, and in all 48 when those calls are included. Token ratios remain within approximately a factor of two in configurations without generation-cap truncation, showing that token counts can obscure substantial energy asymmetry. Counter-injection increases attacker tokens by approximately 9% per level without a detectable pooled change in energy consumption. Enabling thinking on both sides increases defender energy by 8–17 times and reverses the exchange for one model pair in the original campaign. We use these findings to motivate a proposed SCADA deception architecture with private physical state per identified adversary and deterministic protocol and process emulation.

Keywords: Cyber deception; Honeypots; Large language models; GPU energy; SCADA; Critical infrastructure protection

1 Introduction

Three times in ten years an adversary has reached the control functions of a power grid and used them. In December 2015 operators in western Ukraine watched breakers open on their own screens. Remote sessions were driving the human-machine interfaces (HMIs) of three distribution utilities, and approximately 225,000 customers lost power for several hours [2, 3]. A year later the Industroyer malware spoke IEC 60870-5-101, IEC 60870-5-104 and IEC 61850 natively and issued switching commands without a human at a console [4, 5]; its 2022 successor reduced the repertoire to IEC 60870-5-104 alone [6]. In October 2022 the Sandworm group most likely used a native utility of a MicroSCADA installation to relay control commands to remote terminal units, so that the control path carried no malware of its own [7]. The three incidents share the lesson that motivates this article. In each of them the adversary had to learn an unfamiliar

∗^{*}This article extends the workshop paper [1] (AD&D 2026, co-located with ESORICS 2026) with a two-sided energy measurement, the grid architecture and the mission-value scenario; the measurements reported here are new.

†^{\dagger}Corresponding author. E-mail: alamlehh@uncw.edu

Figure

Figure 1: The exchange this article measures, with the three arguments of this section marked where they act: coverage (1) is a premise taken from the literature, counter-injection (2) and the cost exchange (3) are measured in Section 5. Both GPUs are metered.

network before it could act: the HMI and its screens in 2015, the protocol map and the object addresses of the substations in 2016, the supervisory control and data acquisition (SCADA) client and its scripting in 2022. An adversary who reaches a control network is not stopped by the network. It is stopped by the cost of operating in it, and that cost is something a defender can raise on purpose.

Language models lower that cost from the other side. Agentic frameworks now drive penetration tests end to end [8], honeypots have recorded language-model agents attacking in the wild [9], and the workshop paper this article extends argued that generative models lower the adversary's marginal cost of scanning and adapting while they tempt the defender into unbounded compute [1]. That paper adds cost exchange as a metric for decoys, supplementing traditional criteria like realism and detection. It measured only the defender side of the exchange, and it inferred the adversary side from behavioural proxies, because the adversary's hardware is invisible in the field. A control network makes the consequence concrete. A decoy that stalls while its model reasons is dismissed by an operator-grade adversary in minutes, and a defender that spends kilowatt-hours to hold a bot in a fake substation has lost the exchange, whatever the log says. The practitioner's question is therefore not whether the decoy looks real.

It is this: when both sides are language models, who spends more, and which settings decide the sign?

The question presumes that the defender answers a generative adversary with a generative decoy, and the presumption needs an argument. We give three, of different standing; Figure 1 places them on the exchange the article measures.

(i) Coverage, a premise. An agent explores the non-protocol tail of a control network, the shells, the documentation and the engineering workstation, in an open-ended way; in the sessions below it almost never repeats a command. A hand-written emulator covers a fixed command set and is fingerprinted at its edge. A language model is the renderer the generative honeypot literature uses to cover an open space [10, 11], and we take coverage as a premise from that literature; the comparison between a decoy with and without a model belongs to companion work.

(ii) Counter-injection, a countermeasure specific to the adversary. Textual counter-injection exists only against a language-model attacker, because it acts through the prompt the agent reads, and a decoy that decides from the session text is what produces it [9, 12]. Section 5 measures what it does.

(iii) Cost, the measurement of this article. The attacker pays for every token it reads and generates, and a defender that produces plausible text at a lower marginal cost per token exploits that structure. Whether it does so in joules is the measurement of this article, with the physical process kept out of the model by design (Section 6).

None of the three makes the model the only defence of a control network. Together they make it the primary deception component of the architecture studied here against the adversary this article studies, and the question that follows is whether its cost is sustainable.

Two literatures meet here, and neither answers the question. Grid honeynets tie virtual devices to one physical simulation shared by every adversary [13, 14], and measure neither what the deception costs the defender in energy nor what it preserves in mission value. Generative decoys are evaluated for realism and for resistance to fingerprinting [10, 11, 15], never for the two-sided cost of an engagement.

The article makes four contributions. First, it reports the measured energy exchange of Section 5. An autonomous language-model attacker engages a decoy defended by a model of the same family, each on its own identical GPU, and both sides are metered net of idle; eight model pairs, two attacker types and three levels of textual counter-injection give 48 configurations, each run five times, 240 runs, plus 90 runs with thinking mode on. Four results hold across the 330 runs. Token and joule asymmetries diverge, and with thinking off the divergence favours the defender in 42 of 45 cells: the token counts of the two sides stay within about a factor of two while the attacker's GPU energy reaches eight times the defender's. Counter-injection adds about nine percent of attacker tokens per level with no detectable change in the energy of either side. The attacker-to-defender energy ratio exceeds one, with a 95% interval, in 41 of the 48 configurations of the main set under the attribution we declare and in all 48 when every attacker call is counted. Thinking mode, switched on both sides at once, multiplies the defender's energy by 8 to 17 and the attacker's by 3 to 11, and for one pair hands the exchange to the attacker. A replicate of that pair eight days later reproduced the attacker's energy, not the defender's, and left the exchange below parity for the blind attacker and close to it for the reasoning one. Second, it restates the Deception Exchange Rate of the workshop paper as an energy exchange whose denominator names inference, physical simulation and cooling, with the inference term measured and the others estimated. It makes the mission-value term of the sufficiency condition concrete through an illustrative service-interruption scenario built on the 2015 incident and on public value-of-lost-load figures (Sections 4 and 7). Third, it designs a two-level stateful cyber-physical deception architecture for a SCADA network in which each identified adversary owns a private steady-state power flow, so that two concurrent attackers never see each other's manoeuvres (Section 6). The cyber level exists as the SSH bench and the workshop prototype, the physical level is specified, and the text says which is which. Fourth, it evaluates whether the expected loss prevented by deception exceeds its deployment cost, CD<ΔLDC_D < \Delta L_D with measured, sourced and declared numbers, and reduces it to a break-even product of scenario likelihood and prevented loss that an operator can compare with its own estimate (Section 8). Throughout, the attacker's energy is a laboratory quantity, because both GPUs are ours. In the field the adversary's hardware is unobservable, the usable quantity is a conditional estimate of floating-point work from the observed tokens and the inferred model class, and we claim nothing more.

Section 2 places the work against grid honeynets, generative decoys and the energy of language-model inference; Section 3 states the threat model; Section 4 gives the energy-aware cost exchange; Section 5 reports the measurement; Section 6 presents the architecture; Section 7 quantifies mission value on an illustrative grid scenario and Section 8 works the exchange for a grid deployment; Section 9 extends governance to physical invariants, and Section 10 states limitations and the agenda.

Table 1: Positioning against grid honeynets. Properties of the two comparators are taken from the published papers, "not reported" meaning absent from the paper; "designed" marks a property this article specifies without deploying. Computational load and operating cost, which both comparators report, are not rows of this table.

Property[13][14]This paper
Grid simulation tied to decoysyesyesdesigned
Physical state per adversarynonodesigned
Transient dynamics on demandyesnot reporteddesigned, adapted
Automated generationnoyesno
Generative rendering of shellsnonoyes (SSH prototype)
Cost-exchange metricnonoyes
Outage loss monetised (illustrative)nonoyes
Defender GPU energy measurednonoyes
Attacker GPU energy measured (laboratory)nonoyes

References (37)