arXiv:2610.28200cs.LGOct 2026

Manuscript Offprint

arXiv:2610.28200

Parameter-Efficient Adaptation of Time Series Foundation Models for Electrical Load Forecasting

Aliullah, Julian Oelhaf, Edouard Fouché, Jessica Deuschel, Christian Bergler, Andreas Maier, Siming Bayer

Aliullah 1,2∗^{1,2*}, Julian Oelhaf 1∗^{1*}, Edouard Fouché 2^{2}, Jessica Deuschel 2^{2}, Christian Bergler 3^{3}, Andreas Maier 1^{1}, Siming Bayer 1^{1}

1^{1}Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg

2^{2}Siemens AG, Smart Infrastructure

3^{3}Department of Electrical Engineering, Media and Computer Science, Ostbayerische Technische Hochschule Amberg-Weiden

∗^{*}Corresponding authors: ali.ullah@fau.de, julian.oelhaf@fau.de

Abstract—Accurate electrical load forecasting supports power-system operation across countries, regions, cities, and buildings, but repeated development of target-specific models is costly. Time series foundation models (TSFMs) provide reusable pretrained backbones, although multi-domain pretraining may not fully capture load-specific characteristics. This paper compares pretrained inference, full fine-tuning, and low-rank adaptation (LoRA) in terms of forecasting accuracy and adaptation efficiency across four electrical load aggregation levels. MOIRAI 1.0 Large serves as the primary backbone, while Chronos-2 assesses whether the findings transfer across model families. The evaluation covers both in-distribution (ID) and out-of-distribution (OOD) settings and examines whether compact adaptation provides consistent gains over strong pretrained checkpoints. Pretrained foundation models outperform the implemented seasonal naive and XGBoost baselines across the evaluated aggregation levels. On MOIRAI Large, rank-16 LoRA reduces normalized mean absolute error (NMAE) by 7.5% on average while updating 3.146 million parameters, about 1% of the model, and retains most of the improvement from full fine-tuning. Chronos-2 achieves lower pretrained NMAE than MOIRAI, while its relative adaptation gains remain smaller overall. OOD results show that adaptation benefits vary by target, with the clearest gains for the local-area series and several buildings. Overall, LoRA provides a favorable accuracy-efficiency trade-off when adaptation yields a meaningful gain over a strong pretrained checkpoint.

Index Terms—electrical load forecasting, time series foundation models, parameter-efficient fine-tuning, LoRA, MOIRAI

I. INTRODUCTION

Accurate electrical load forecasting is essential for reliable and economically viable power-system operation. Short-term forecasts inform generation scheduling, balancing and reserve decisions, market participation, demand response, and the operation of local energy systems and buildings. Forecasting difficulty also changes with aggregation: national and regional demand is comparatively smooth, while city and building loads are more strongly affected by weather, occupancy, operating schedules, and local equipment behavior [1], [2].

In practice, many systems, market areas, customer groups, and buildings require individual load forecasts. Conventional forecasting approaches can provide strong local performance, but they often require models to be trained separately for individual series or datasets [3]. As the number of forecasting targets grows, model configuration and training must therefore be repeated across more series. For comparison, a weekly seasonal naive model provides a meaningful reference because electrical load exhibits daily, weekly, and seasonal structure, with many series showing strong weekly repetition. Gradient-boosted trees provide a supervised machine-learning alternative using lagged load and external covariates [4]. Both approaches can be effective, but target-specific models and feature pipelines limit their scalability across large forecasting collections.

Time series foundation models (TSFMs) offer a reusable pretrained alternative. TSFMs aim to transfer temporal representations learned from large and heterogeneous datasets. MOIRAI, a TSFM, provides a universal and covariate-aware architecture for forecasting across frequencies and dimensions [5]. Chronos formulates forecasting as token prediction [6], and Chronos-2 extends this model family to univariate, multivariate, and covariate-informed forecasting [7]. Recent peak-aware evaluation across area-code, secondary-substation, and low-voltage-feeder levels found that Chronos-2 performed strongly during high-demand periods across all three distribution-grid aggregation levels [8]. A strong pretrained checkpoint can therefore provide zero-shot forecasts, meaning forecasts without target-specific training, across diverse electrical load series.

The remaining question is how much downstream adaptation such a pretrained model requires for electrical load forecasting. Three practical options exist: (i) pretrained inference applies the pretrained checkpoint without downstream training; (ii) full fine-tuning specializes the complete model by updating all model parameters; and (iii) low-rank adaptation (LoRA) provides an intermediate option by freezing the pretrained backbone and learning compact low-rank updates in selected transformations [9]. Quantized low-rank adaptation (QLoRA) combines low-rank adaptation with a quantized backbone [10], and weight-decomposed low-rank adaptation (DoRA) decomposes weight updates into directional and magnitude components [11]. The present work focuses on LoRA because the primary question is not which parameter-efficient fine-tuning (PEFT) variant performs best, but whether compact adaptation retains sufficient forecasting accuracy to provide an operationally attractive alternative to full fine-tuning. The value of LoRA therefore depends on whether it retains the relevant accuracy gains of full fine-tuning while updating far fewer task-specific parameters.

Existing work shows that pretrained models can be competitive in electricity and building load forecasting and that lightweight adaptation can be effective in narrower settings [12], [13]. However, it remains unclear when PEFT is preferable to pretrained inference or full fine-tuning across electrical load aggregation levels, and whether adaptation gains transfer to unseen systems and buildings. This study addresses that gap through a systematic benchmark of pretrained inference, full fine-tuning, and LoRA across country-level, regional-level, city-level, and building-level load series. MOIRAI 1.0 Large serves as the primary backbone, while Chronos-2 tests whether the central findings transfer to a second model family. The benchmark combines in-distribution (ID) and out-of-distribution (OOD) evaluation with analyses of adapter rank, PEFT method, training-data composition, trainable parameters, and graphics processing unit (GPU) configurations.