Can a Display Be Used for Rapid LiDAR-Camera Extrinsic Calibration?

Zuhao Zou, Xiangcheng Hu, Jianhao Jiao, Jin Wu

Zuhao Zou, Graduate Student Member, IEEE, Xiangcheng Hu, Jianhao Jiao, and Jin Wu, Senior Member, IEEE

Abstract—ScreenCalib enables light detection and ranging (LiDAR)—camera extrinsic calibration using an ordinary programmable display, providing known visual markers and controlled geometry while reducing dedicated target preparation. The camera observes displayed AprilTags, whereas the LiDAR measures the physical screen surface and boundary, requiring indirect cross-modal association. Display geometry introduces association ambiguities, while indoor clutter complicates extraction. ScreenCalib addresses these challenges through tag-guided display extraction, geometric hypothesis generation and refinement, and surrounding scene edges for ambiguity resolution. The single-pose mode requires only one static placement. The joint multipose mode combines independent static observations through cross-pose consensus and jointly refines the shared extrinsics and tag scale, reducing sensitivity to tag-size measurement errors without requiring continuous motion or inter-pose trajectory estimation. Experiments in simulation and on three different sensor platforms cover mechanical and nonrepetitive LiDARs in clean and cluttered environments. Benchmark results show that ScreenCalib outperforms competitive calibration-board-based methods in translation accuracy. Joint multi-pose refinement further reduces mean rotation and translation errors across the three platforms and improves rendered-map alignment. Evaluation across readily available displays, including cell phones, tablets, laptops, computer monitors, and televisions, further examines ScreenCalib's versatility as a practical alternative to dedicated calibration targets. The source code is available at https://github.com/ZuhaoZou2026/ScreenCalib.

Index Terms—Camera calibration, light detection and ranging (LiDAR), multisensor systems, robot sensing systems.

I. INTRODUCTION

Accurate extrinsic calibration between light detection and ranging (LiDAR) sensors and cameras is fundamental to multimodal perception [1], multimodal place recognition [2], and three-dimensional reconstruction [3]. In practical robotic systems, however, calibration is constrained not only by estimation accuracy, but also by how easily reliable calibration observations can be obtained during deployment. Existing methods typically make a trade-off between these two requirements. As illustrated in Fig. 1, target-based methods deliberately introduce known and repeatable geometric structures, but require dedicated target preparation and deployment. Targetless methods substantially reduce this burden, but the available calibration constraints depend on the surrounding environment and sensor motion. When the scene does not provide sufficiently informative geometry or texture, or when the motion excitation is inadequate, the calibration problem can become weakly constrained, leading to unstable estimates, degraded accuracy, or even calibration failure. This raises a straightforward practical question: can we achieve reliable and repeatable LiDAR-camera calibration without carrying and setting up a dedicated calibration target?

Target-based LiDAR–camera calibration uses specially designed structures, such as planar boards, circular holes, or checkerboards, to establish explicit cross-modal correspondences [4]–[6]. The known and repeatable target geometry (as priors) generally provides well-constrained and reliable calibration. However, this comes with a relatively high deployment burden, as the target must be fabricated or printed, accurately measured, transported, and positioned for each calibration.

Targetless methods occupy the other end of this trade-off. They avoid dedicated calibration objects by exploiting natural scene appearance, geometric structures, sensor motion, or learned cross-modal correspondences [7], [8]. This reduces deployment burden, but the resulting calibration strongly depends on scene structure and motion excitation; insufficient or repetitive observations can lead to unstable estimates or calibration failure. Some methods also rely on accurate initialization, odometry, or trajectory optimization, further increasing sensitivity to acquisition conditions.

ScreenCalib is designed to reduce this dependency without returning to a specially manufactured calibration target. Instead of carrying and setting up a dedicated board, we use an ordinary display as a programmable cross-modal calibration interface. The displayed pattern provides known and repeatable visual geometry to the camera, while the physical display surface and its finite boundary provide geometric structure to the LiDAR. The displayed content can be electronically generated and adjusted according to sensing distance, field of view, and image resolution, without printing, attaching, or machining a dedicated target. As illustrated in Fig. 1, this places ScreenCalib between conventional target-based and targetless calibration: it preserves a user-provided and repeatable calibration structure while substantially reducing the deployment burden associated with a dedicated target.

This work was supported by National Key Research and Development Program under the grant of 2025YFB4711400, National Natural Science Foundation of China under the grant of 62603050; Zuhao Zou and Xiangcheng Hu contributed equally to this work. (Corresponding author: Jin Wu)

Importantly, however, a display is not simply an electronic replacement for a conventional calibration board. In conventional target-based calibration, both sensing modalities

Z. Zou is with the Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong (e-mail: zuhao.zou@connect.hku.hk); X. Hu is with the Department of Electronic and Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong (e-mail: xhubd@connect.ust.hk); J. Jiao is with Lion Rock AI Lab (e-mail: jiaojh1994@gmail.com); J. Wu is with the School of Artificial Intelligence, University of Science and Technology Beijing, Beijing, China (e-mail: jin_wu_uestc@hotmail.com).

Figure

Fig. 1. Comparison of target-based, ScreenCalib, and targetless LiDAR–camera calibration. Target-based methods provide known and repeatable geometry and direct cross-modal association, but require dedicated target preparation. Targetless methods minimize deployment burden by exploiting natural scene structure, but the available calibration geometry depends on the environment. ScreenCalib uses an ordinary programmable display to retain known calibration geometry while reducing dedicated target preparation. Its main challenges are the indirect association between camera and LiDAR observations and the cluttered environments in which displays are commonly located.

are typically associated through the same physical target features. In ScreenCalib, the two modalities observe different manifestations of the display. The camera directly observes the displayed AprilTags, whereas the LiDAR generally cannot observe these visual fiducials and instead measures the physical screen surface and boundary. The cross-modal relationship must therefore be established indirectly through their shared display geometry. This is the first practical difficulty.

The second one is that, the planar geometry of the display inherently introduces association ambiguities: multiple permutations of the four image and LiDAR corners may produce apparently plausible initial transformations. These characteristics make display-based calibration substantially different from directly applying a conventional calibration-board pipeline.

The third practical difficulty arises from where displays are normally used. Unlike a dedicated calibration target that can be placed in a clean acquisition area, displays are commonly located in offices, laboratories, and other cluttered indoor environments. Nearby objects can generate competing image edges and planar LiDAR clusters, while the display boundary may be sparsely or noisily sampled, especially by nonrepetitive solid-state LiDARs.

Furthermore, ScreenCalib requires a measured AprilTag side length as input, and this measurement may be inaccurate. In single-pose data, LiDAR measurement noise can inflate points near the display boundary, making it difficult to jointly estimate the tag size and extrinsics accurately. This motivates joint multi-pose calibration.

To address these challenges, we propose ScreenCalib, a display-based LiDAR–camera calibration framework with single-pose (SP) and multi-pose (MP) modes. The main contributions are as follows:

• Robust Display Extraction in Two Different Modalities. We use an ordinary programmable display as a calibration target. On the camera side, AprilTag detections define a reliable polygon around the displayed pattern. Because the pattern and outer display boundaries are parallel in the display plane, the projected pattern edges guide the search for the outer display boundary in the image. The AprilTag-derived depth prior range-filters LiDAR points for display-cloud extraction. The detected tags also provide a pixel-to-meter ratio, which, together with the image-polygon size, gives a metric size cue for LiDAR display extraction. Experiments in cluttered environments demonstrate the robustness of display extraction.

• Single-pose calibration with indirect cross-modal association. We develop a complete calibration pipeline requiring only one static display placement. Multiple camera–LiDAR display associations are explicitly retained, initialized from the display geometry, refined by finite-support registration, and validated using surrounding cross-modal scene structures. This enables rapid calibration even when the display is surrounded by cluttered indoor objects.

• Joint multi-pose calibration. We extend the framework to multiple independently captured static display observations without requiring continuous motion or interpose trajectory estimation. Cross-pose consensus selection identifies a consistent initialization from single-pose extrinsic proposals. Joint optimization then combines image-edge, plane, and normal constraints to refine a shared LiDAR–camera transformation and a correction to the user-measured AprilTag size.

• Carefully designed experimental evaluation. We examine complementary aspects of the framework: simulation with ground truth; three real LiDAR–camera systems, including mechanical and nonrepetitive LiDARs; clean and cluttered environments; indirect real-world accuracy assessment against Kalibr-estimated inter-camera extrinsics; qualitative assessment through rendered point-cloud alignment; sensitivity to user-measured AprilTag size;

Figure

Fig. 2. Examples of display devices used in the ScreenCalib evaluation, each showing the calibration pattern: (a) cell phone, (b) tablet, (c) laptop, (d) computer monitor, and (e) television.

and calibration across five display types (Fig. 2).