arXiv:2608.25472cs.CVAug 2026

Manuscript Offprint

arXiv:2608.25472

PAGS: Autofocusing Photoacoustic Tomography via Speed-of-Sound-Adaptive Gaussian Splatting

Jiarui Ge, Jintao Ma, Bangxu Fan, Jinyan Zhang, Xiaokang Yang, Shuai Na, Xiaoyun Yuan

Abstract

Photoacoustic computed tomography (PACT) combines optical absorption contrast with acoustic detection for high-resolution deep-tissue imaging. A persistent challenge is that unknown speed-of-sound (SoS) heterogeneity changes acoustic time-of-flight, causing defocusing artifacts when reconstruction assumes a uniform SoS. Existing SoS-adaptive methods either rely on calibrated acoustic priors or optimize dense physical medium models, which becomes expensive and difficult to scale in 3D. We propose PAGS, a differentiable framework for blind autofocusing PACT via speed-of-sound-adaptive Gaussian splatting. PAGS represents the initial pressure field with sparse Gaussian photoacoustic (PA) sources and replaces explicit medium recovery with a compact anisotropic path-averaged SoS (ASoS) field parameterized by spherical harmonic probes. This latent propagation field directly controls source-to-transducer arrival-time alignment, while an analytic Gaussian acoustic projection maps the source representation to transducer signals efficiently. The resulting closed-loop signal-domain optimization jointly updates the Gaussian PA source parameters and the ASoS field from measured data, without calibrated SoS priors. Experiments on simulated and physical phantom data demonstrate im-

proved reconstruction sharpness under heterogeneous acoustic media, robustness to sparse-view sampling, and computational benefits from the analytic Gaussian projection.

Keywords Photoacoustic Computed Tomography · Gaussian Splatting · Speed-of-Sound Adaptation · Autofocus

Electronic Supplementary Material Supplementary Video 1 provides rotating three-dimensional comparisons of vanilla UBP, Dual-SoS UBP, SlingBAG, and PAGS, together with PAGS reconstructions at different sampling ratios.

1 Introduction

Photoacoustic computed tomography (PACT) is a non-invasive imaging modality that combines optical absorption contrast with acoustic detection [1]. As illustrated in Fig. 1, a short laser pulse excites light-absorbing chromophores, such as hemoglobin or melanin, and the resulting thermoelastic expansion generates broadband ultrasonic waves that are recorded by surrounding transducers. Reconstructing the initial pressure field from these time-resolved acoustic measurements enables high-resolution structural and functional mapping of biological tissues. This capability has made PACT useful in a wide range of preclinical and clinical studies, including vascular imaging, neuroimaging, and tumor characterization.

Corresponding author: E-mail: shuai@pku.edu.cn.

Corresponding author: E-mail: yuanxiaoyun@sjtu.edu.cn.

The quality of PACT reconstruction, however, is strongly affected by the assumed speed of sound (SoS). Standard analytical reconstruction methods, such as universal back-projection (UBP) [2], commonly assume a globally uniform SoS. Real tissue and surrounding coupling media often have different acoustic speeds, so

1^{1}MoE Key Lab of Artificial Intelligence, Institute of AI, School of Computer Science, Shanghai Jiao Tong University, Shanghai, China.

2^{2}National Biomedical Imaging Center, College of Future Technology, Peking University, Beijing, China.

3^{3}Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, China.

4^{4}Key Laboratory of Machine Perception, Ministry of Education, Beijing, China.

5^{5}PKU–Nanjing Institute of Translational Medicine, Nanjing, China.

J. Ge et al

Figure

Fig. 1 Overview of the proposed PAGS framework for blind autofocusing photoacoustic tomography. Compared with universal back-projection (UBP) under a uniform speed-of-sound (SoS) assumption, PAGS represents the initial pressure field with sparse Gaussian photoacoustic (PA) sources and learns an anisotropic path-averaged SoS (ASoS) field with spherical harmonic (SH) probes, enabling focused reconstruction without calibrated SoS priors.

the same photoacoustic source can have different path-averaged SoS values toward different transducers [1, 3]. These path-dependent arrival-time errors lead to defocusing, geometric distortion, and loss of fine vascular detail. Correcting unknown SoS-induced aberration is therefore a central problem for high-resolution PACT.

Existing SoS-adaptive reconstruction strategies face a difficult trade-off. Prior-informed multi-SoS reconstruction can improve focusing when tissue boundaries and regional SoS values are known, but such calibrated acoustic priors are often unavailable and may require additional segmentation or auxiliary measurements. More general iterative or learning-based approaches can optimize a dense physical medium or scalar SoS map jointly with the absorption distribution [3, 4], but the arrival-time correction needed for focusing is obtained only after path integration through that medium. This high-dimensional parameterization and indirect forward dependency make blind 3D optimization computationally expensive and prone to poor local solutions.

We propose PAGS, a differentiable framework for blind autofocusing PACT via speed-of-sound-adaptive Gaussian splatting. Building on Gaussian-based reconstruction [5,6], the key idea is to replace explicit recovery of the full acoustic medium with a latent anisotropic path-averaged SoS (ASoS) field that directly controls source-to-transducer arrival-time alignment. PAGS represents the initial pressure field with sparse Gaussian photoacoustic (PA) sources and represents the propagation effect with compact spherical harmonic (SH) probes anchored on a spatial grid. For each Gaussian PA source and transducer direction, PAGS queries the ASoS field, projects the source to the transducer signal using an analytic Gaussian acoustic model, and optimizes the source and propagation parameters in a single signal-domain loop.

This design aligns the representation with the structure of the inverse problem. The PA source distribution is sparse and localized, making Gaussian PA sources a natural continuous primitive for vascular structures. The heterogeneous acoustic medium is not recovered directly; instead, its accumulated effect on propagation is expressed as a smoother, lower-dimensional ASoS field over source locations and transducer directions. As a result, PAGS focuses on the propagation variable that directly affects reconstruction sharpness while avoiding the cost and ambiguity of dense medium recovery.

The main contributions are summarized as follows:

  1. We introduce a latent ASoS propagation field for blind PACT autofocusing. It models direction-varying path-averaged SoS directly, avoiding explicit dense acoustic medium recovery and calibrated SoS priors.

  2. We couple the ASoS field with sparse Gaussian PA sources and an analytic Gaussian acoustic projection, enabling efficient differentiable optimization from measured transducer signals.

  3. We validate PAGS on simulated and physical phantom data, including sparse-view settings and component ablations, showing improved focusing under heterogeneous acoustic media and favorable efficiency from the analytic projection.

References (25)