arXiv:2610.22748cs.HCOct 2026

Manuscript Offprint

arXiv:2610.22748

ElectroCalm: Investigating User Experience and Physiological Responses to Multi-Node Transcutaneous Electrical Stimulation for Stress Modulation

Yoon Kyung Shon, Pablo E. Paredes

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

YOON KYUNG SHON, University of Maryland, USA

PABLO E. PAREDES, University of Maryland, USA

Transcutaneous Electrical Stimulation (TES) for stress modulation has largely focused on vagus nerve stimulation at the neck, yet two questions remain underexplored: how users experience electrotactile sensations at this sensitive site, and whether electrotactile feedback itself can function as a haptic stress intervention. To investigate this gap, we applied an 8-node TES array to two body sites during a cognitively demanding 2-back task: the neck, a site used in prior vagal TES research for its anatomical proximity to the cervical vagus nerve, and the arm, the most common haptic wearable site, which primarily provides cutaneous electrotactile sensation without vagal access. In a usability study, both sites were rated as comparably comfortable without disrupting task performance, though the same stimulation was interpreted differently across sites. A second study assessing the physiological effects of active versus inactive stimulation under identical electrode attachment revealed that only neck TES produced cortical and autonomic changes consistent with stress modulation, while arm TES did not differ from inactive conditions. These findings suggest that neck TES can be acceptable despite the site's sensitivity, and that both the physiological effects and the sensory experience of TES depend on placement.

CCS Concepts: • Human-centered computing → Haptic devices; Ubiquitous and mobile computing systems and tools; Empirical studies in ubiquitous and mobile computing; • Applied computing → Consumer health.

Additional Key Words and Phrases: Stress, Mental Health, Intervention, Haptics, Electrical Stimulation, Electrotactile, User Experience, Wearable

ACM Reference Format:

Yoon Kyung Shon and Pablo E. Paredes. 2026. ElectroCalm: Investigating User Experience and Physiological Responses to Multi-Node Transcutaneous Electrical Stimulation for Stress Modulation. Proc. ACM Interact. Mob. Wearable Ubiquitous Technol. 10, 4, Article 253 (December 2026), 25 pages. https://doi.org/10.1145/3857961

1 INTRODUCTION

Stress is an essential physiological process that supports human survival at appropriate levels [113]. However, repeated activation of stress responses chronically engages the sympathetic nervous system [57]. Over time, this contributes to physical and mental health problems, including cardiovascular disease, psychological disorders, and impaired work performance [111]. This motivates approaches that modulate daily stress responses before they accumulate into chronic strain [12], particularly in environments that constitute a significant portion of daily life, such as cognitively demanding workplaces [37, 92].

Among such approaches, haptic feedback is well-suited for non-disruptive, everyday use. Previous studies have shown it could operate unobtrusively during cognitive tasks [11, 69, 109], as it is often processed with minimal attentional resources [83]. Studies also demonstrated that haptic feedback can convey comfort and engage parasympathetic responses that reduce physiological stress markers [22, 35].

Authors' Contact Information: Yoon Kyung Shon, University of Maryland, College Park, Maryland, USA, ykshon@umd.edu; Pablo E. Paredes, University of Maryland, College Park, Maryland, USA, paredes@umd.edu.

Figure

This work is licensed under a Creative Commons Attribution 4.0 International License.

© 2026 Copyright held by the owner/author(s).

ACM 2474-9567/2026/12-ART253

https://doi.org/10.1145/3857961

Proc. ACM Interact. Mob. Wearable Ubiquitous Technol., Vol. 10, No. 4, Article 253. Publication date: December 2026.

253:2

• Yoon Kyung Shon and Pablo E. Paredes

Within the broader family of haptics, Transcutaneous Electrical Stimulation (TES) offers distinct advantages for stress modulation. Unlike mechanical or thermal actuators, TES requires only thin, silent electrodes without moving parts [71, 102], and can access autonomic pathways beyond the somatosensory system depending on electrode placement [38]. Studied primarily in neuroscience contexts [81, 82], TES delivers low-voltage currents through skin electrodes at the neck to target the vagus nerve, a major cranial nerve that regulates autonomic body functions [104]. The neck is therefore the most common TES placement for stress modulation, yet it is also a sensitive site for tactile stimulation [31]. Combined with the fact that electrotactile stimulation is often perceived as unpleasant in prior HCI research [17, 28], it remains unclear whether users can tolerate and accept electrical stimulation at this sensitive site.

Beyond vagal targeting, TES inherently produces electrotactile sensations through somatosensory pathways [20, 25]. However, existing TES research has focused almost exclusively on clinical efficacy and vagal mechanisms rather than the experiential and physiological role of the tactile component itself. This gap is notable because other haptic modalities, such as vibrotactile feedback, have demonstrated stress modulation through somatosensory pathways [12, 46, 68]. Whether electrotactile feedback can similarly contribute to stress modulation remains an open question for practical deployment where sensory experience shapes adoption [52, 88, 98].

We therefore study two research questions. RQ1, how do users perceive and experience TES on the neck, a sensitive site rarely explored in haptic HCI? RQ2, can electrotactile stimulation at a site without vagal access modulate physiological stress? To that end, we utilized an 8-node electrode array with cross-fading activation patterns inspired by calming sequential haptic patterns [69, 70]. By distributing stimulation across multiple nodes, we aimed to reduce single-point electrotactile discomfort while creating smooth spatiotemporal patterns. We applied this system to two body sites: the neck and the arm. The neck served as the physiologically targeted TES site, following prior work on autonomic modulation [38], while its sensitivity to electrotactile stimulation motivates RQ1 [31]. The arm is a conventional haptic wearable site where user experience is well established [51]. Because arm stimulation is expected to act primarily through cutaneous electrotactile sensation rather than cervical vagal targeting [1], this site comparison addresses RQ2.

Using a within-subject design, we assessed user experience, physiological responses including electroencephalography (EEG) and heart rate variability (HRV), and performance on the cognitively demanding 2-back task [8, 20, 52]. We first conducted a usability study with exploratory physiological assessment at both sites. Both neck and arm TES were rated as comparably comfortable, despite distinct tactile experiences. Task performance remained stable, suggesting that TES did not interfere with cognitive performance. Exploratory physiological measures showed promising changes at both sites relative to a device-free control, but could not determine whether effects reflected active stimulation or electrode presence alone. We therefore conducted a second study comparing active and inactive stimulation under identical electrode attachment. The two sites dissociated: neck TES produced cortical and autonomic changes consistent with stress modulation, whereas arm TES did not differ from inactive conditions. Together, these results suggest that physiological stress modulation appeared specific to neck placement, and that TES can be acceptable on the sensitive neck despite its sensitivity.

Contribution. This paper makes the following contributions:

• We showed that multi-node spatiotemporal TES can produce acceptable and comfortable experiences on the neck, a sensitive site rarely explored in haptic HCI, rated comparably to the arm.

• We demonstrated that neck TES produced consistent cortical and autonomic stress modulation, whereas arm TES did not differ from inactive stimulation, indicating that physiological stress modulation was specific to neck placement.

• We provide design implications for TES stress modulation, including separating physiological targeting from tactile comfort, designing for acceptability at sensitive body sites, and considering how body site shapes the sensory interpretation of stimulation.

Proc. ACM Interact. Mob. Wearable Ubiquitous Technol., Vol. 10, No. 4, Article 253. Publication date: December 2026.

ElectroCalm: Investigating User Experience and Physiological Responses to Multi-Node Transcutaneous Electrical Stimulation for Stress Modulation • 253:3

References (79)