Abstract—MRI field-strength enhancement seeks to combine the accessibility of low-field scanners with the image quality of high-field scanners. Yet, existing methods remain prone to anatomical hallucinations, as uniform processing leaves difficult brain regions insufficiently examined and scarce paired data limit their learning of how tissue contrast and anatomical visibility change across field strengths. To address these challenges, we propose UniField++, a two-agent framework that unifies enhancement tasks across multiple field-strength transitions, including 64mT-to-3T and 3T-to-7T. Unified learning allows both the VLM-based planner and the flow-matching-based enhancer to draw on field-dependent image characteristics observed across tasks, rather than relying on a single transition. Trained with radiologists' annotations of hallucination-prone regions and corresponding correction plans, the planner predicts regional risk and formulates targeted restoration strategies. Guided by these plans, the enhancer performs loop reasoning along the flow-matching trajectory, repeatedly processing high-risk regions for additional refinement. Together, cross-transition learning and risk-guided refinement support anatomically faithful enhancement across field strengths. Across the evaluated tasks, UniField++ improves PSNR by an average of 2.74 dB and SSIM by 14.05 percentage points over comparison methods, with corresponding gains of 3.97 dB and 13.92 percentage points over the ablation baseline. It also maintains enhancement quality on an external cohort with an unseen field strength and improves downstream whole-brain segmentation Macro Dice by an average of 0.1457 over the original low-field images. Code is available at https://github.com/CUHK-AIM-Group/UniField_plusplus.

Index Terms—Magnetic resonance imaging (MRI), multi-agent systems, Unified field-strength enhancement, and Loop reasoning

Yiyang Lin, Tianliang Yao, Shuaibo Li, and Yixuan Yuan are with the Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China. (e-mail: yylin247@163.com; yxyuan@ee.cuhk.edu.hk).

Chenhui Wang is with the Institute of Science and Technology for Brain-inspired Intelligence, Fudan University, Shanghai 200433, China.

Zijun Sun is with the Institute of Diagnostic Radiology, University Hospital Zurich, University of Zurich, Zurich 8091, Switzerland.

Yiming Deng is with the Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing 100070, China, and also with the China National Clinical Research Center for Neurological Diseases, Beijing, China. (e-mail: dengyiming@bjth.org).

Corresponding authors: Yiming Deng and Yixuan Yuan.

Figure

Fig. 1. Overview of UniField++. Our framework unifies enhancement tasks across various types of field strengths. And UniField++ primarily comprises a VLM-based planner that simulates the radiologists' planning process for enhancement, and a flow-matching-based enhancer that executes the enhancement according to the plan.

I. INTRODUCTION

Magnetic resonance imaging (MRI) is one of the most important non-invasive imaging modalities in modern clinical practice, with systems operating at magnetic field strengths ranging from ultra-low field, through high-field systems commonly used in clinical settings, to ultra-high field. Specifically, portable low-field systems, such as 64mT scanners, are affordable and easy to deploy, but their low signal-to-noise ratio (SNR) limits spatial resolution and anatomical detail [1]–[3]. Meanwhile, 1.5T and 3T systems are the mainstay of routine clinical MRI, providing higher SNR and clearer anatomical detail than ultra-low-field systems [1]. Moreover, ultra-high-field 7T systems can further improve anatomical resolution and tissue contrast, but their wider adoption is constrained by greater financial and infrastructure requirements [4]. To combine the affordability and deployment flexibility of low-field MRI with the excellent image quality of high-field MRI, computational field-strength enhancement aims to improve the anatomical detail and visual quality of low-field images toward those of high-field acquisitions.

Recent advances in MRI field-strength enhancement have been demonstrated by methods such as LoHiResGAN for 64mT-to-3T translation [5] and MSFA for 3T-to-7T synthesis [6]. However, these approaches remain vulnerable to hallucinations, with two key limitations concerning the breadth of field-strength knowledge and the depth of regional reasoning.

First, existing enhancement methods have limited knowledge of how field strength affects tissue contrast and the visibility of anatomical structures, often treating enhancement primarily as a low-level super-resolution task. Limited paired datasets further constrain the acquisition of this knowledge: the KCL dataset contains 23 subjects for 64mT-to-3T enhancement [7], while the UNC and BNU datasets contain only 10 and 20 subjects, respectively, for 3T-to-7T enhancement [8], [9]. Consequently, generated images may resemble high-field MRI while misrepresenting the patient's actual anatomy. For example, they may suppress a small lesion or introduce a lesion-like structure [10], [11].

Second, field-strength enhancement is not equally difficult across anatomical regions. While structures that are clearly visible in the low-field image may require relatively straightforward enhancement, poorly resolved or ambiguous regions require more careful interpretation and are more prone to hallucination [11]–[13]. However, existing methods generally process these regions with the same fixed level of scrutiny, rather than allocating additional reasoning steps to difficult regions. Even with broad prior knowledge, a model may therefore favor familiar structural patterns over patient-specific evidence. For example, it may reconstruct a poorly resolved sulcus as a tissue bridge between adjacent gyri. This motivates adaptive reasoning depth to further examine and refine regions at greater hallucination risk.

Thus, we propose UniField++, a unified multi-agent framework for MRI field-strength enhancement, as illustrated in Fig. 1. It comprises two cooperating agents: a vision-language model (VLM)-based planner and a flow-matching-based enhancer. By bringing multiple field-strength transitions into a shared framework, UniField++ draws on a broader range of relationships between field strength, tissue contrast, and anatomical visibility than any single transition can provide. On the top of that, first, we incorporate radiologists' annotations of hallucinations and corresponding correction plans into the planner, enabling it to identify hallucination-prone regions and propose targeted corrections. Second, guided by the planner's risk assessments and correction plans, the enhancer performs loop reasoning along the flow-matching trajectory, repeatedly routing high-risk brain patches through a key processing stage for additional refinement. In this way, both agents support broader field-strength knowledge and adaptive reasoning depth to reduce hallucinations. Our contributions are as follows:

• We propose UniField++, a unified multi-agent framework that decouples reasoning from enhancement through separate planner and enhancer, allowing each to focus on its task while reducing interference between the processes.

• We introduce a radiologist-informed VLM-based planner that learns field-strength knowledge through radiologist annotations, producing masks of high-risk regions and corresponding correction plans.

• We develop a flow-matching-based enhancer with dynamic reasoning that uses the masks and plans to allocate additional inference resources to high-risk regions through Loop Transformer blocks.

• UniField++ achieves average PSNR/SSIM gains of 2.74 dB/14.05 percentage points over competing methods and 3.97 dB/13.92 percentage points over the plain baseline in ablation experiments.

UniField++ substantially extends our preliminary framework, UniField [14], published at MICCAI 2026, in two key aspects. First, we enable UniField++ to prospectively identify regions prone to hallucination during field-strength enhancement and formulate explicit correction plans specifying the restoration strategies through a VLM-based agent. Second, guided by the predicted high-risk region masks and corresponding correction plans, we redesign the enhancement model to dynamically allocate its reasoning budget [15] according to local hallucination risk, allocating additional reasoning resources to high-risk regions through loop reasoning with a Loop Transformer. These extensions consistently improve upon UniField across all five task–modality combinations, yielding average gains of 0.96 dB in PSNR and 5.62 percentage points in SSIM.

References (45)