arXiv:2610.24390cs.AIOct 2026

Manuscript Offprint

arXiv:2610.24390

Trust the Edge, Doubt the Arrow: Auditing Validation Signals for Text-Mined Clinical Causal Knowledge Graphs

Su Lan, Shicheng Zhou, Yiqi Wang, Yanming Zhu, Xuefei Yin, Alan Wee-Chung Liew

Su Lan*, Shicheng Zhou*, Yiqi Wang, Yanming Zhu, Xuefei Yin, and Alan Wee-Chung Liew✉

School of Information and Communication Technology, Griffith University, Gold Coast, QLD, Australia

  • These authors contributed equally to this work.

✉ Corresponding author: a.liew@griffith.edu.au.

Abstract. Clinical causal retrieval-augmented generation systems increasingly use knowledge graphs (KGs) mined from notes, yet extracted assertions remain candidates that require audit for patient-level EHR support and direction. We construct a directed candidate graph from 328,839 MIMIC-IV discharge summaries using LLM extraction and UMLS normalization, and evaluate three signals against SemMedDB: within-admission co-occurrence lift, cross-admission diagnosis-coding temporal precedence, and literature corroboration. Lift filters unsupported co-mentions and provides useful EHR support, but not causal proof. Coding order is a weak direction signal: among the 686 candidates where it commits, it reaches 54.2% agreement with SemMedDB, below the extractor's 69.4% on the same subset. Literature corroboration supplies independent direction evidence but covers only 30.4% of candidate relations. A MIMIC-III replication yields the same pattern: extractor direction remains stable (70.5%), whereas coding-order direction is near chance (50.9%). Thus, text-mined clinical causal candidate KGs are best treated as EHR-supported but direction-uncertain. In a leakage-controlled causal QA benchmark, lift-only retrieval achieves 35.7% accuracy; conservative causal demotion achieves 37.2% while reducing evidence-unsupported answers from 17.3% to 6.1% at fixed retrieval recall. We release code, aggregate summaries, and scripts to regenerate restricted outputs.

Keywords: Clinical causal knowledge graph · Knowledge graph auditing · Retrieval-augmented generation · Electronic health records · Clinical NLP.

1 Introduction

Mining causal relations from clinical narratives (“hepatic encephalopathy due to alcoholic cirrhosis”) can produce causal candidate KGs for clinical reasoning. Recent causal RAG retrieves over text-mined causal graphs so that evidence carries

S. Lan et al.

direction [30]. These systems must decide which extracted candidates are reliable enough to retrieve. That decision has two parts: whether an LLM-extracted causal assertion has patient-level EHR support, and whether its direction has independent support. An LLM reading notes can emit clinically plausible causal assertions, unsupported co-mentions (“chest pain → abdominal pain”), and reversed candidates. A natural audit strategy is to use structured EHR signals: keep candidate relations whose endpoints co-occur more than expected and orient them by the order in which diagnoses appear over time. Yet these assumptions are rarely tested against an external reference. Unsupported candidates add retrieval noise, while misdirected candidates can lead a system to answer a causal question with a downstream consequence rather than an upstream cause. We therefore ask which signals can support an extracted relation and which can provide usable direction evidence.

We build a directed causal candidate KG from 328K MIMIC-IV discharge summaries and audit three validation signals against SemMedDB, a literature-derived causal-predicate database independent of our pipeline (Fig. 1):

– Co-occurrence lift provides EHR support: it filters unsupported co-mention candidates and improves downstream causal-QA correctness.

– Cross-admission temporal precedence is unreliable as an independent EHR direction signal: against literature direction, it is correct on only 54.2% of the candidates where it commits, worse than the extractor on the same subset (69.4%). ICD coding order reflects discovery, not onset, a hazard known to structured causal discovery [27] that we quantify here for text-mined candidates.

– Literature corroboration provides direction evidence but limited coverage: it covers 30.4% of all candidate relations and agrees with the extractor's direction on roughly three quarters of the covered subset.

Together, these results reveal a practical asymmetry: patient-level EHR support can be screened using a simple co-occurrence signal, whereas causal truth is not established and direction remains uncertain. We therefore treat text-mined clinical causal candidate KGs as EHR-supported but direction-uncertain: co-occurrence lift is used to filter unsupported candidates, the extractor's direction is retained as an imperfect text-derived estimate, and coding-order time is not used to orient candidates. Rather than proposing a new generator architecture, this work provides an audit and reusable benchmark for assessing when causal candidates mined from clinical text are reliable enough to support retrieval.

Our contributions are summarized as follows.

  1. A patient-grounded causal QA benchmark with leakage-controlled, dual-signal reference answers. The benchmark pairs clinician-stated causal assertions with EHR support, making it a targeted test bed for support-filtered causal retrieval rather than a claim of causal ground truth.

  2. A systematic audit of three validation signals against independent literature evidence, yielding the EHR-supported, direction-uncertain asymmetry. Co-occurrence lift filters unsupported candidates, while cross-admission coding order is near chance and literature corroboration is coverage-limited.

  3. A reproducible pipeline for clinical causal candidate KG construction from 328K discharge notes, combining LLM extraction, UMLS normalization, per-candidate audit metadata, and cross-release replication on MIMIC-III.

  4. A controlled causal-RAG study in which lift-only retrieval serves as the audit-consistent baseline after the temporal-direction audit. A conservative causal-demotion policy preserves recall, substantially reduces evidence-unsupported answers, and gives a small non-significant accuracy trend.

Figure

Fig. 1. Overview of the proposed audit-and-retrieval framework. Build: causal candidates are mined from clinical notes and normalized to UMLS concepts. Audit: co-occurrence lift provides EHR support, coding-order time is unreliable for direction, and SemMedDB provides partial literature corroboration. Apply: support-aware causal RAG retrieves from the EHR-supported candidate graph and demotes candidates that fail the causal screen, reducing evidence-unsupported answers at fixed recall.

References (33)