Transport What Shares the Conduction Pathway: Normal-Anchored SPD Geometric Transport for Source-Free Patient Adaptation of Holter and Patch ECG

JinKook Kim

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Electrocardiogram (ECG) beat classifiers lose accuracy on new patients and devices, and source-free adaptation methods that assume class-balanced target batches fail on real recordings, whose label-free prefix is 87.9–98.6% normal beats. We propose Normal-Anchored Geometric Transport (NAGT, GA_NS), which estimates a closed-form symmetric positive-definite congruence map from label-free normal anchors in the first 5 min of each recording and applies it only to the normal and supraventricular prototypes, keeping the ventricular and fusion prototypes fixed. The score offsets and decision rules were set on MIT-BIH only; the rate-invariant RR head (relA) was adopted after the development databases (INCART, SVDB) had been opened; the frozen model was then evaluated once on Icentia11k chest-patch recordings under a pre-registered protocol. In 493 patients (973 recordings, 3,615,388 evaluated beats), NAGT reached an arrhythmia macro-F1 J=12(S−F1+V−F1)=48.7%J = \frac{1}{2}(S-F1 + V-F1) = 48.7\% [95% CI 42.1, 54.7] versus 34.5% without adaptation ( ΔJ=+14.1\Delta J = +14.1 [+8.6, +19.3] pp; 59.8% versus 43.9% in non-AF) and outperformed all five Holm-adjusted comparators, including AdaBN, Tent and T3A. In the 75-patient test subgroup of the historical split (73 analyzed), the gain was not significant (+6.1 [-8.5, +23.4] pp). Adaptation takes a median of 5.8 ms per record without back-propagation.

1 Introduction

Inter-patient ECG beat classification remains the weakest link in automated Holter and wearable-patch analysis pipelines. When a model is evaluated on new patients that it did not observe during training (e.g., the MIT-BIH DS1/DS2 inter-patient split protocol 1^{1}), the high accuracy achieved in intra-patient splits is lost abruptly. A substantial part of this loss is morphological: even for the same ventricular electrical activation, the QRS waveform projected onto a surface lead varies considerably with the electrode position, the thoracic geometry and the individual myocardial conduction properties. In particular, single-channel wearable chest patches, which are now spreading in clinical and everyday monitoring, have an anatomical lead configuration (e.g., modified lead I) entirely different from the limb leads used in most annotated databases, and therefore further aggravate cross-device and cross-lead domain shift.

Source-free domain adaptation (SFDA) and test-time adaptation (TTA) have been proposed to mitigate such domain shift without access to the original training data. Representative examples are AdaBN 2^{2}, which replaces batch-normalization (BN) statistics with those of the target

*Corresponding author. E-mail: jinkook@huinno.com; jkook1218@gmail.com segment; Tent 3^{3}, which additionally updates the BN affine parameters by back-propagation so as to minimize the Shannon entropy of the predictions; and T3A 4^{4}, which adjusts class templates with confident low-entropy pseudo-labels. These techniques, however, rely on the implicit premise that the target adaptation batch resembles the class-mixture distribution of source training. Real continuous patient ECG recordings strongly violate this assumption: across the four databases of this study, the proportion of normal (N) beats among the label-free prefix beats reached 89.4–91.3% in MIT-BIH, 87.9% in INCART, 88.6% in SVDB and 98.6% in Icentia11k, whereas the source encoder was trained with class-balanced batches (25% per class) for rare-arrhythmia detection. We show that in this setting, among the eight main evaluation sets, AdaBN falls below the non-adapted model (G0) on all eight, Tent on seven and T3A on four, and that on Icentia11k all three methods collapse well below G0 (Section 2.2).

Riemannian alignment offers a geometric alternative that does not modify network weights directly: it removes session- and subject-specific affine distortions by re-centering covariance matrices to a common reference point 5,6^{5,6}. However, if this approach is applied unchanged to ECG beat classification and a single global map moves all class prototypes at once (GA_All and RPA-Recenter), every beat class is treated as if it shared the same patient-specific morphological distortion. Ventricular ectopic beats (V) do not: V beats originate from an ectopic focus in the ventricular myocardium and spread by cell-to-cell propagation rather than through the His-Purkinje conduction system. We demonstrate that the map estimated from a patient’s normal beats moves the ventricular prototype away from that patient’s actual ventricular beats in 75.4–100% of the record × seed units across the four databases (Section 2.4). Conversely, moving only the normal prototype (GN) absorbs the supraventricular beats (S), whose waveforms resemble normal beats, into the normal cluster, and moving the fusion prototype (F) as well (GA_SV) causes a balloon effect in which borderline normal beats flow massively into V (Section 2.3).

To address these limitations, the main contributions of this study are as follows:

  1. Normal-Anchored Geometric Transport (NAGT / GA_NS): we propose an adaptation technique that estimates a patient-specific SPD congruence map from label-free normal anchors in the first 5-min prefix, applies it only to the supraventricular classes that share the normal conduction pathway (N, S), and fixes the ventricular (V) and fusion (F) prototypes at their source positions. The adaptation is computed in closed form, requires no back-propagation and changes no network parameter (Fig. 1a,b).

  2. Rate-invariant relative-RR branch and score offsets: by combining dimensionless local relative-interval features (relA, adopted after INCART/SVDB were opened) with fixed score offsets determined only within MIT-BIH ( δS=1\delta_{S} = 1, δF=0.5\delta_{F} = 0.5), the method resolves the sinus-tachycardia S false positives induced by absolute RR features and the heart-rate drift of long Holter recordings.

  3. Error-flow analysis and identification of the geometric abstention buffer: we quantify the mechanisms by which moving the V prototype causes V→S and V→N leakage and moving the F prototype causes the N→V balloon effect, and we show that the F prototype fixed at the source acts as a geometric abstention buffer that absorbs ambiguous borderline beats and protects V precision.

a Dual-branch beat classifier and label-free 5-min prefix adaptation (per recording)

Figure

b Geometric transport and abstention buffer on the SPD manifold S++8S_{++}^{8} (AIRM / Log-Euclidean) (schematic, not to scale)

Figure

GA_NS: move N, S; keep V, F

O source prototype PcP_c (frozen)

• transported P~c=ApPcAp⊤\tilde{P}_c = A_p P_c A_p^\top

patient beats of class c

→ geodesic transport (GA_NS)

→ same map on PVP_V (GA_All)

F abstention buffer

→ borderline N beat → F (blocks N → V, ×)

Fig. 1. Overview of NAGT (GA_NS). (a) Dual-branch model and label-free adaptation pipeline. Each beat is encoded by a frozen convolutional encoder into an 8×88 \times 8 SPD covariance descriptor C(x)C(x) and scored by its Log-Euclidean distance to the class prototypes; a parallel rate-invariant relative-RR branch (relA) adds RR logits and the fixed offsets δS=1\delta_S = 1, δF=0.5\delta_F = 0.5. From the label-free 5-min prefix, U1 normal anchors (non-premature beats with p(N)≥0.5p(N) \geq 0.5 under the four-dimensional RR head, 80% core of the patient's own covariance cloud) define the AIRM mean M^N\hat{M}_N and the closed-form congruence map ApA_p (Eq. (3)), which transports only PNP_N and PSP_S. (b) Schematic tangent-space view: the N and S prototypes move to the patient's normal-derived position, whereas the V and F prototypes stay at the source; the fixed PFP_F acts as a geometric abstention buffer that absorbs borderline normal beats as F instead of V. Applying the same map to PVP_V (GA_All) would move it away from the patient's actual V beats (Section 2.4). Panel (b) is illustrative, not data.

  1. Large-scale pre-registered one-shot confirmation on chest-patch ECG and transparent history reporting: the frozen final model was evaluated a single time, at one unsealing, on Icentia11k (single-channel chest patch, 493 patients), confirming statistical superiority over four literature SFDA baselines and three geometric controls, and the full development and validation history, including negative pre-registered results, is reported transparently (Supplementary Table 1).