Manuscript Offprint
arXiv:2610.24585DeliMF: Gated Cross-Attention Fusion of Structured Time Series and Clinical Text for Early Intensive Care Delirium Prediction
Yibo Yang Zerui Huang Haomiao Yang Zixia Wang
Independent Researcher, China
Xinjin District People's Hospital, China University of Exeter, United Kingdom
yang.374960202@gmail.com huangruirui92@gmail.com
cdhmyang@126.com zw483@exeter.ac.uk
These authors contributed equally to this work and share first authorship.
Corresponding author.
Abstract—Delirium affects a large fraction of intensive care unit (ICU) patients and foreshadows longer stays, lasting cognitive decline, and higher mortality. Flagging the patients who will become delirious within the first day of admission would give clinicians a window to intervene. Yet state-of-the-art predictors rely only on the structured electronic health record (EHR) of vital signs, laboratory values, and medications, while overlooking the free-text clinical notes written in the same window, which carry information the numbers cannot encode. To this end, we present DeliMF, a multimodal framework that fuses the structured time series with clinical text. It encodes the structured signals with a temporal Transformer and the time-stamped radiology reports with a clinical text encoder, and fuses the two through a gated cross-attention module. The gate learns a per-patient weight on the text; when a patient has no note the gate closes and DeliMF reduces to its structured-only form, giving robustness to missing text by construction. On an incident-only MIMIC-IV cohort, DeliMF improves significantly over the baselines, particularly on patients who carry clinical text, while losing nothing on those without. Ablation studies confirm the contribution of multimodal fusion and gated cross-attention, and a case study further shows that fusing clinical text with the structured stream recovers delirium cases that the structured data alone misses. We hope DeliMF encourages early ICU prediction to make fuller use of the overlooked clinical text and contributes to the early identification and timely intervention of delirium.
Index Terms—ICU delirium prediction, multimodal fusion, clinical text, gated cross-attention
I. INTRODUCTION
Delirium is an acute and fluctuating disturbance of attention and awareness, and it ranks among the most common neuropsychiatric complications of critical illness [1]–[3]. Delirium in critically ill survivors is linked to long-term cognitive impairment comparable to moderate traumatic brain injury [4], and in older patients more broadly it predicts higher mortality [5]. Many precipitants of delirium are modifiable. Intervening before onset, for instance by protecting sleep and withdrawing deliriogenic drugs, can reduce its incidence and shorten its course [6]. Such interventions are only meaningful before an episode begins. Flagging high-risk patients before onset is therefore of considerable value, since early risk identification can guide the timely use of preventive measures [7].
Delirium risk modeling has progressed from hand-crafted clinical scores [8] to machine learning. E-PRE-DELIRIC [7] estimates risk from a handful of admission variables and remains a common clinical reference. PRIDE [9] and the dynamic model [10] push performance on structured features with gradient boosting and neural networks respectively. DeL-LiriuM [11] reframes the task for a large language model by serializing the electronic health record (EHR) into a prompt [12]. All of these methods build on structured EHR, the numerical record of vitals, labs, and medications. They provide effective tools for ICU delirium prediction.
However, clinical text carries information that is equally valuable [13] yet left unused by prior methods. In other ICU prediction tasks, integrating multimodal clinical data has been shown to improve performance [14], [15]. The notes written in the first hours of an ICU stay routinely name the very factors that drive delirium but are not recorded in the EHR, for example: a head CT that reads “subarachnoid hemorrhage,” a history of “alcoholic cirrhosis,” or a radiograph showing “acute pneumonia.” We aim to exploit this overlooked information, together with the structured data, for delirium prediction.
Building on this observation, we propose DeliMF (Delirium Multimodal Fusion), a new framework that fuses two modalities, the structured time series and the clinical text. Figure 1 traces our full pipeline through a representative case. Specifically, DeliMF has three parts. It models the structured stream with a temporal Transformer that leverages the actual timestamp of each observation rather than aligning the data to a fixed temporal grid. For the text stream, it uses only radiology reports recorded prior to the prediction time, so as to avoid information that would be unavailable at that time. The two representations are then fused by a gated cross-attention module, in which the structured representation queries the text for descriptive context and a gate weights the textual and structured representations per patient.

Fig. 1. Overview of DeliMF, traced through a real MIMIC-IV case (61-year-old admitted after a fall, incident-delirium label). The structured tower embeds each event from its value, feature id, and timestamp and encodes the sequence with a temporal Transformer, pooled to . The text tower encodes the first-24h radiology report with ClinicalBERT, pooled to . In the gated cross-attention module, the structured states query the text, and a per-patient gate weights the two representations into the fused ; when no note is available the gate closes and DeliMF reduces to its structured-only form. A two-layer MLP head maps to the delirium probability. For this case the report names a subarachnoid hemorrhage with diffuse axonal injury, precipitants absent from the tabular record, and DeliMF raises the probability to 0.56 while the structured-only baseline assigns 0.21 and misses the case.
Finally, we conduct extensive experiments to validate and evaluate DeliMF. On a cohort restricted to incident cases in the ICU, DeliMF improves significantly over the baselines. We further conduct ablation studies that isolate the contribution of multimodal fusion and gated cross-attention, analyze the learned per-patient gate, and present a case study tracing the true delirium cases that DeliMF recovers over the structured-only model, showing that clinical text indeed provides effective information for delirium prediction beyond the structured data.
Overall, our contributions are summarized as follows:
-
We identify and exploit the clinical text overlooked by prior prediction. Early clinical text records many precipitants that drive delirium yet resist structured encoding, and we introduce this text as a separate modality for prediction.
-
We propose DeliMF, a multimodal fusion framework based on gated cross-attention. It models the structured stream as a native time series and the text with a clinical text encoder, and weights the two representations through a per-patient gate.
-
We conduct extensive experiments, including comparison with baselines, ablation studies, and a case study, that validate DeliMF and show that fusing clinical text with the structured stream through gated cross-attention yields gains beyond either modality alone and beyond naive fusion.
Multimodal clinical learning. Multimodal fusion is an active direction in deep learning [18], [19] and is well developed for modalities such as image and text, typically aligning and fusing the representations of different modalities through contrastive learning or cross-modal attention [20], [21]. In the clinical domain, this idea has been used to bring in clinical text beyond the structured EHR. Some work [14], [15], [22] jointly models physiological time series and clinical notes for in-hospital mortality and readmission, generally finding that text supplies context the structured fields cannot encode. A complementary line learns to weight each modality's contribution with a gate rather than fixing the fusion scheme [23], and gating has also been applied to irregular multimodal EHR [24], though there the gate resolves irregularity within each modality while the cross-modal fusion itself rests on attention. DeliMF differs from these works in two respects. The first is the clinical setting, as it targets early, incident ICU delirium prediction. The second is the model structure, as it models the structured stream as a native time series and places a per-patient gate directly across the fused text and structured representations, so the gate both adapts modality reliance to each patient and closes to recover the structured-only model when no note is available.
III. METHOD
A. Problem formulation
For each ICU stay we observe the first 24 hours after admission and predict whether the patient develops delirium after that window. The cohort is incident-only: stays already delirious or comatose within the first 24 hours are excluded, so the task is genuine prediction rather than detection. Let a stay be represented by a structured event sequence and, when available, a clinical text ; the label marks subsequent incident delirium. DeliMF estimates .
B. Structured temporal encoder
The structured stream is a sequence of irregularly timed events, where each event is a triple of a continuous value , a feature index identifying one of the structured variables, and a timestamp . In the spirit of Transformer input construction, each event is mapped to a token embedding as the sum of three terms:
i.e. a value term, a feature term, and a time term, where is a learned per-feature embedding table indexed by , is the per-feature value projection selected by the same index, and the timestamp is encoded by a learnable continuous function
with a vector of learnable frequencies; the sine and cosine terms are concatenated and mapped to the -dimensional token space by the MLP, so that the encoding reflects the real spacing between observations rather than a fixed grid. Each stay is padded to a common length with a binary mask marking real events; stacking the token embeddings of over a batch of stays gives , which an -layer Transformer encoder [25] processes under this padding mask:
(3)
i.e. token states and, for each stay , a mean over its valid (non-padded) tokens; stacking the gives the pooled summary .
C. Clinical text encoder
The radiology reports written within the first 24 hours are ordered by time and concatenated into a single text , encoded with a clinical text encoder; we use ClinicalBERT [26] as the default and study a Qwen2.5 [27] alternative in Section IV-F. Writing for the contextual states and Proj for a linear map to the shared dimension , the token states are the projected sequence and the pooled vector is the projected summary state:
(4)
where is the last non-padded position of stay . Stacking the gives . The two backbones differ in how this summary is read: the encoder-only ClinicalBERT uses its [CLS] state, whereas the decoder-only Qwen uses the last token, whose causal receptive field spans the whole report.
D. Gated cross-attention fusion
The two streams meet in the fusion module. Structured token states query the text states through multi-head cross-attention, letting physiological trajectory attend to descriptive context. The structured states form the queries and the text states form the keys and values. Each of the heads projects them with learned matrices into a dimensional subspace,
and attends over the text with a scaled dot-product, masking padded and absent text tokens:
where is an additive mask, shared across heads, that suppresses padded or absent text tokens before the softmax,
so that a masked key receives zero attention weight. The heads are concatenated and projected back to the shared dimension by an output matrix ,
and stabilized by a residual connection and layer normalization,
followed by masked mean pooling to . Rather than mixing the two streams with a fixed coefficient, a gate conditioned on both pooled summaries decides per patient how much of the cross-attended evidence to admit. The gate is a two-layer MLP on the concatenated summaries, and the text-availability flag (one if stay has a note) modulates the fused representation:
(10)
Because is a nonlinear function of the inputs and acts per dimension, it is an input-adaptive, per-patient weight on the text-informed representation rather than a shared constant. The second-layer bias is initialized negative (, giving at the start of training), so the model leans on the structured stream first and admits text only as it proves useful. When a stay has no note, zeroes the gated term, giving exactly, so DeliMF reduces precisely to its structured-only form. This gives missing-modality robustness by construction. A two-layer MLP head maps to a delirium probability , and the model is trained by a class-weighted binary cross-entropy that counteracts the low positive prevalence:
where the sum runs over the B stays in a batch and the positive weight is the ratio of negative to positive stays in the training set.
E. Two-stage training
Trained end-to-end from scratch, the high-capacity text encoder destabilizes optimization and contaminates even the temporal pathway. We therefore train in two stages: (i) freeze the text encoder and train the structured encoder, fusion, and head; (ii) unfreeze the upper text-encoder layers and fine-tune jointly at a smaller learning rate. Combined with the negative gate bias, this lets the temporal pathway settle before the text is introduced as an increment. Section IV-D reports the effect of this schedule against an end-to-end variant.
IV. EXPERIMENTS
A. Data and cohort
We build the cohort from MIMIC-IV [28] together with its note module. Delirium labels are reconstructed from charted CAM-ICU [29] features under the BRAIN-ICU three-state scheme of normal, delirium, and coma [4]. To avoid label contamination, an “unable to assess” reading is treated as coma rather than negative. The reconstructed labels agree with the native delirium-assessment item on 93.8% of scored intervals, confirming their reliability. We then restrict the cohort to incident-only stays, excluding those with prevalent delirium or coma in the first 24 hours, early death, or a non-first ICU admission. The resulting cohort comprises 23,431 stays at a 10.7% positive prevalence and is split by patient into training, validation, and test sets, as summarized in Fig. 2a.
The test set contains 4,688 stays. Of these, 2,599 stays, or 55.4%, carry a radiology report time-stamped within the
(a) Cohort construction

(b) Age vs. delirium rate

(c) Text availability (test)

(d) Event density

Fig. 2. Data and cohort overview. (a) Cohort construction from all brain-status-assessed ICU stays down to the incident-only cohort of 23,431; the final (red) bar is the analyzed cohort. (b) Age distribution (bars) and delirium rate (line), which rises monotonically with age. (c) Text availability on the test set: 55.4% of stays carry a radiology report, and the with-text subgroup has a higher positive rate. (d) Distribution of structured events per stay (mean 217).
prediction window, while the remaining 44.6% have no accompanying text (Fig. 2c). Because text is restricted to notes whose time stamp precedes the prediction point, the setup is leakage-safe. Two further properties of the cohort are worth noting. Delirium incidence rises monotonically with age, from 6.4% below age 35 to 15.1% above age 85 (Fig. 2b), and each stay contributes 217 structured events on average (Fig. 2d).
B. Implementation
The structured encoder uses a model dimension of with 8 attention heads and 4 layers. We optimize with AdamW under a cosine schedule with warmup and a class-weighted loss, and apply differentiated learning rates: for the structured and fusion parameters and for the text encoder. Every model is run with three random seeds, and we report the mean and standard deviation across seeds. Statistical significance against the baselines is assessed with a paired bootstrap of resamples, drawing test cases with replacement.
C. Metrics
We report two threshold-free areas,
AUROC [30] remains stable under class imbalance, whereas AUPRC responds to the positive prevalence [31]. On our skewed cohort, whose positive rate is only 10.7%, the precision-recall view is therefore the more informative one [32]. We accordingly treat AUPRC as the primary metric and read AUROC as a secondary, optimism-prone signal. At a 0.5 threshold we additionally report sensitivity, specificity, and F1, and we summarize calibration with the Brier score [33], for which lower values are better.
D. Comparison with prior delirium-prediction methods
Table I compares DeliMF against the structured-only model and two published baselines reimplemented under our cohort and protocol: the DeLLiriuM-style serialization model [11] and an E-PRE-DELIRIC-style predictor [7]. On AUROC the full model and the structured-only model are statistically indistinguishable. On AUPRC, which is the metric that matters under heavy imbalance, DeliMF pulls clearly ahead. The contrast with the DeLLiriuM-style baseline is sharper still. That model serializes the structured record into a prompt and discards its temporal order, and DeliMF improves AUROC over it by more than eight points at . We read this as direct evidence that the structured stream is best served by native temporal modeling rather than by language-model framing. This comparison also puts the published DeLLiriuM result in perspective. Its reported external AUROC of 0.824 [11] was obtained on a different cohort under a different label definition and is thus not directly comparable to ours; once cohort and protocol are held fixed, the serialization approach falls behind. Text alone is a weak predictor, which is unsurprising, as radiology reports are an indirect signal and cover only part of the cohort. The text modality earns its place only when fused with the structured stream, not when substituted for it.
E. DeliMF design ablation
DeliMF rests on three design choices: multimodal fusion, token-level cross-attention, and the input-adaptive gate. We isolate the first two by replacing each with a simpler alternative while holding every other component fixed, using three seeds and the two-stage schedule throughout. The gate is examined separately, through its missing-modality behavior in Section IV-F and its learned distribution in Section IV-I. All results in this analysis are reported in Table I.
Multimodality. Removing the text branch reduces DeliMF to its structured-only form and gives back the AUPRC it had gained, a loss of roughly two and a half points at . Removing the structured branch instead leaves the text-only model, whose AUROC collapses by some twenty points. The two modalities are therefore not interchangeable: text complements structure but cannot stand in for it.
Fusion design. Replacing gated cross-attention with simple concatenation costs close to two AUROC points at , and late fusion fares no better. This exposes a real risk rather than a marginal preference. When fused naively, a weak modality can drag performance below the structured-

Fig. 3. Subset analysis across text availability and age (3 seeds, mean±std). (a) AUROC and (b) AUPRC for DeliMF, the structured-only model, and two structured-input baselines. DeliMF's AUPRC gain concentrates on the with-text and elderly subgroups, while it matches structured-only when no note is present. The DeLLiriuM-style and E-PRE-DELIRIC-style baselines use only structured inputs, so they are unaffected by note availability.
only model, and avoiding exactly this failure is what the gate is designed for.
Cross-attention. Holding the fusion structure fixed while feeding it the pooled text vector in place of token-level cross-attention costs about two AUPRC points. The fine-grained interaction between physiological trajectory and descriptive context thus contributes measurably and is not a decorative part of the design.
Taken together, each design choice is justified by these results, as removing any one of them brings DeliMF down to, or below, the structured-only AUPRC.
F. Backbone sensitivity
Beyond DeliMF’s design choices, we verify that the gains are not artifacts of any single backbone. Replacing the temporal Transformer with a bidirectional GRU [34] costs a little over one AUROC point and leaves AUPRC essentially unchanged. This gap is small and non-significant, yet it still supports our emphasis on native temporal modeling. The text encoder behaves similarly. Substituting ClinicalBERT with Qwen2.5-1.5B [27] leaves whole-cohort performance unchanged and nudges the with-text AUROC slightly upward, indicating that a stronger pretrained language model yields a text representation at least as useful for this task.
G. Subset analysis
Splitting the test set by text availability sharpens the picture, as shown in Fig. 3. Among the patients who carry a note, slightly more than half of the cohort, DeliMF attains an AUPRC significantly higher than the structured-only model at p = 0.002. Among those with no note, where the gate closes and the model falls back on structure alone, it does not lose ground. The framework thus adds signal where text exists and forfeits nothing where it does not. Because nearly half the patients contribute no text, the whole-cohort AUROC gain is modest by construction, which is why we rest the headline on AUPRC and on the with-text population rather than on a sweeping AUROC claim.
TABLE I
COMPARISON ON THE MIMIC-IV TEST SET (3 SEEDS, MEAN ± STD; THRESHOLD 0.5). THE TABLE IS ORGANIZED INTO BLOCKS: COMPARISON WITH PRIOR METHODS, SINGLE-MODALITY ABLATION, FUSION DESIGN, TRAINING SCHEDULE, AND ENCODER SUBSTITUTION. OUR FULL MODEL IS SHADED; BEST PER COLUMN IN BOLD BLUE (LOWER IS BETTER FOR BRIER).
| Model | AUROC | AUPRC | F1 | Sens. | Spec. | Brier |
|---|---|---|---|---|---|---|
| Comparison with prior methods | ||||||
| DeliMF (ours) | 0.803 ± 0.003 | 0.360 ± 0.012 | 0.391 ± 0.018 | 0.718 ± 0.036 | 0.762 ± 0.037 | 0.162 ± 0.016 |
| DeLLiriuM-style | 0.721 ± 0.000 | 0.242 ± 0.001 | 0.316 ± 0.006 | 0.545 ± 0.037 | 0.770 ± 0.032 | 0.182 ± 0.015 |
| E-PRE-DELIRIC-style | 0.692 ± 0.000 | 0.189 ± 0.000 | 0.283 ± 0.000 | 0.624 ± 0.000 | 0.666 ± 0.000 | 0.228 ± 0.000 |
| Single-modality ablation | ||||||
| Structured-only | 0.800 ± 0.002 | 0.334 ± 0.007 | 0.390 ± 0.003 | 0.663 ± 0.057 | 0.791 ± 0.031 | 0.148 ± 0.013 |
| Text-only | 0.602 ± 0.022 | 0.169 ± 0.012 | 0.246 ± 0.016 | 0.327 ± 0.077 | 0.843 ± 0.047 | 0.223 ± 0.030 |
| Fusion design | ||||||
| Concat fusion | 0.784 ± 0.006 | 0.348 ± 0.019 | 0.377 ± 0.022 | 0.657 ± 0.078 | 0.775 ± 0.068 | 0.166 ± 0.030 |
| Late fusion | 0.782 ± 0.003 | 0.331 ± 0.013 | 0.371 ± 0.005 | 0.636 ± 0.036 | 0.784 ± 0.024 | 0.165 ± 0.013 |
| Training schedule (two-stage is our default, top row) | ||||||
| DeliMF (end-to-end) | 0.795 ± 0.004 | 0.359 ± 0.005 | 0.368 ± 0.036 | 0.699 ± 0.083 | 0.736 ± 0.096 | 0.183 ± 0.054 |
| Encoder substitution | ||||||
| Qwen2.5 (text encoder) | 0.801 ± 0.004 | 0.361 ± 0.004 | 0.374 ± 0.023 | 0.722 ± 0.066 | 0.738 ± 0.067 | 0.176 ± 0.028 |
| GRU (struct encoder) | 0.790 | 0.349 | - | - | - | - |
H. Age subgroup
Stratifying the test set by age yields a clinically coherent pattern (Fig. 3). Delirium becomes both more common and harder to predict with advancing age: incidence climbs from below ten percent in the younger group to more than thirteen percent at age sixty-five and above, while AUROC drifts downward across the same divide. DeliMF's gain settles where the burden is heaviest. In the elderly subgroup its AUPRC reaches 0.366 against 0.328 for the structured-only model, a gain of 3.8 points, whereas below sixty-five the two are essentially on par at 0.357 versus 0.351. The text therefore helps most for the high-risk older population, which is precisely the group a delirium early-warning tool is meant to serve.

Fig. 4. Gate value distribution over patients with text. The mean of 0.45 and the left tail show per-patient adaptive reliance on the text modality.
I. Interpretability
Gate behavior. Across patients with text, the gate centers slightly below one half and spreads over a broad range, trailing off into a left tail of patients the model reads mostly from structured signals (Fig. 4). Rather than settling on a fixed mixing constant, it behaves as an adaptive per-patient weight on the text modality, which is exactly the behavior the design was meant to produce.
Case study. The most revealing patients are those that the structured-only model misses but DeliMF recovers. Across the test set, 16 truly delirious patients receive a structured-only probability below 0.5 yet a DeliMF probability above it. In every one of these cases, the note carries a recognized delirium precipitant that the tabular record does not encode well: a head CT reading “subarachnoid hemorrhage” with “diffuse axonal injury”; a history of “alcoholic cirrhosis” under immunosuppression with suspected infection; “acute pneumonia” in a hypoxic nonagenarian; a status-post “subdural hematoma” evacuation; or a report noting that the study was “degraded by patient motion,” with agitation itself being a harbinger of delirium. Representative examples are listed in Table II. Collectively, these cases span the classic precipitant categories of acute brain injury, infection, alcohol withdrawal, the post-operative state, and advanced age. What sets these phrases apart is not the diagnosis alone but its framing: an enlarging hemorrhage, a consolidation that could be pneumonia, an infection flagged as a possible precipitant, or a scan degraded by motion. Such dynamic and hedged descriptions are precisely what a tabular feature cannot represent, and they show concretely what the aggregate metrics report: the text supplies context the numbers omit.
TABLE II REPRESENTATIVE CASES THE STRUCTURED-ONLY MODEL MISSES BUT DELIMF CATCHES (TRUE LABEL: DELIRIUM). THE LAST COLUMN QUOTES VERBATIM PHRASES FROM THE FIRST-24 H RADIOLOGY REPORT, SHOWING THAT DELIMF RECOVERS TRUE DELIRIUM CASES BY EXTRACTING ADDITIONAL INFORMATION.
| Age | Struct. | DeliMF | Evidence in the radiology report |
|---|---|---|---|
| 61 | 0.21 | 0.56 | 1. Parietal hemorrhage enlarging: “12 × 12 mm” vs. “8 × 5.5 mm” prior2. “consistent with diffuse axonal injury” |
| 68 | 0.29 | 0.68 | 1. “EtOH cirrhosis c/b ascites, varices,” HCC s/p liver transplant2. immunosuppressed “on tacrolimus”3. “possible infection as precipitant” |
| 91 | 0.37 | 0.69 | 1. “Hypoxic respiratory failure”2. right-lower-lobe consolidation that “could be acute pneumonia” |
| 75 | 0.47 | 0.55 | 1. S/p “subdural hematoma evacuation,” two burr holes2. collection decreased: 19 vs. 26 mm |
| 45 | 0.14 | 0.63 | 1. C7 fracture with “extensive edema”2. study “substantially degraded by patient motion” (agitation) |
V. DISCUSSION
Our results indicate that clinical text helps where it exists, and that it helps most on the metric reflecting positive-class quality. The whole-cohort AUROC gain over the structured-only model is small and not statistically significant. This outcome is expected rather than disappointing, since 44.6% of patients contribute no note and the available notes are radiology reports, an inherently indirect signal. What the text does provide is a significant AUPRC gain on the with-text population and, through the gate, robustness on the remainder. For a deployment whose purpose is to surface high-risk patients for intervention, precision-recall on the positive class is the quantity that matters most, and it is precisely there that DeliMF improves on the structured-only model.
Several limitations bound these claims. First, radiology reports are only one slice of the clinical narrative; integrating nursing notes or chief complaints, for instance through concept-based text modeling [35], is a natural next step. Second, our evaluation is confined to the single-center MIMIC-IV cohort and lacks external validation. Third, we do not test robustness to erroneous or manipulated notes, to which language models are known to be vulnerable [36], [37]. None of these limitations undercuts the controlled comparisons within our fixed cohort and protocol.
VI. CONCLUSION
DeliMF fuses structured ICU time series with real, leakage-safe clinical text through a gated cross-attention module that adapts to each patient and degrades gracefully when text is absent. Our experiments show that early clinical text carries usable signal for ICU delirium prediction, that a learned per-patient gate exploits this signal where it exists while protecting the model where it does not, and that gated cross-attention extracts more from the text than naive fusion or EHR serialization does. Together, these findings indicate that reading the clinical notes is worth the effort, and they point toward richer note types and external cohorts as promising next steps.
REFERENCES
[1] J. L. Stollings, K. Kotfis, G. Chanques, B. T. Pun, P. P. Pandharipande, and E. W. Ely, “Delirium in critical illness: clinical manifestations, outcomes, and management,” Intensive care medicine, vol. 47, no. 10, pp. 1089–1103, 2021.
[2] J. E. Wilson, M. F. Mart, C. Cunningham, Y. Shehabi, T. D. Girard, A. M. MacLullich, A. J. Slooter, and E. W. Ely, “Delirium,” Nature reviews Disease primers, vol. 6, no. 1, p. 90, 2020.
[3] K. Kotfis, E. W. Ely, and Y. Shehabi, “Intensive care unit delirium—a decade of learning,” The Lancet Respiratory Medicine, vol. 11, no. 7, pp. 584–586, 2023.
[4] P. P. Pandharipande, T. D. Girard, J. C. Jackson, A. Morandi, J. L. Thompson, B. T. Pun, N. E. Brummel, C. G. Hughes, E. E. Vasilevskis, A. K. Shintani et al., “Long-term cognitive impairment after critical illness,” New England Journal of Medicine, vol. 369, no. 14, pp. 1306–1316, 2013.
[5] S. K. Inouye, “Delirium in older persons,” New England journal of medicine, vol. 354, no. 11, pp. 1157–1165, 2006.
[6] K. Sosnowski, F. Lin, W. Chaboyer, K. Ranse, A. Heffernan, and M. Mitchell, “The effect of the abcde/abcdef bundle on delirium, functional outcomes, and quality of life in critically ill patients: a systematic review and meta-analysis,” International Journal of Nursing Studies, vol. 138, p. 104410, 2023.
[7] A. Wassenaar, M. van den Boogaard, T. van Achterberg, A. Slooter, M. Kuiper, M. Hoogendoorn, K. Simons, E. Maseda, N. Pinto, C. Jones et al., “Multinational development and validation of an early prediction model for delirium in icu patients,” Intensive care medicine, vol. 41, no. 6, pp. 1048–1056, 2015.
[8] M. Van den Boogaard, P. Pickkers, A. Slooter, M. Kuiper, P. Spronk, P. Van Der Voort, J. Van Der Hoeven, R. Donders, T. van Achterberg, and L. Schoonhoven, “Development and validation of pre-deliric (prediction of delirium in icu patients) delirium prediction model for intensive care patients: observational multicentre study,” Bmj, vol. 344, 2012.
[9] S. Hur, R.-E. Ko, J. Yoo, J. Ha, W. C. Cha, and C. R. Chung, “A machine learning-based algorithm for the prediction of intensive care unit delirium (pride): retrospective study,” JMIR medical informatics, vol. 9, no. 7, p. e23401, 2021.
[10] K. D. Gong, R. Lu, T. S. Bergamaschi, A. Sanyal, J. Guo, H. B. Kim, H. T. Nguyen, J. L. Greenstein, R. L. Winslow, and R. D. Stevens, “Predicting intensive care delirium with machine learning: model development and external validation,” Anesthesiology, vol. 138, no. 3, pp. 299–311, 2023.
[11] M. Contreras, S. Kapoor, J. Zhang, A. Davidson, Y. Ren, Z. Guan, T. Ozrazgat-Baslanti, J. Sena, S. Nerella, A. Bihorac et al., “A large language model for delirium prediction in the intensive care unit using structured electronic health records,” Scientific Reports, vol. 15, no. 1, p. 38890, 2025.
[12] Y. Yang, F. Lei, Y. Sun, Y. Zeng, C. Lv, J. Hong, J. Tian, T. Qiu, X. Wang, Y. Chen et al., “Aidabench: Ai data analytics benchmark,” arXiv preprint arXiv:2603.15636, 2026.
[13] B. Van Rompaey, M. M. Elseviers, M. J. Schuurmans, L. M. Shortridge-Baggett, S. Truijen, and L. Bossaert, “Risk factors for delirium in intensive care patients: a prospective cohort study,” Critical care, vol. 13, no. 3, p. R77, 2009.
[14] W. Lyu, X. Dong, R. Wong, S. Zheng, K. Abell-Hart, F. Wang, and C. Chen, “A multimodal transformer: Fusing clinical notes with structured ehr data for interpretable in-hospital mortality prediction,” in AMIA Annual Symposium Proceedings, vol. 2022, 2023, p. 719.
[15] I. Deznabi, M. Iyyer, and M. Fiterau, “Predicting in-hospital mortality by combining clinical notes with time-series data,” in Findings of the association for computational linguistics: ACL-IJCNLP 2021, 2021, pp. 4026–4031.
[16] S. N. Shukla and B. M. Marlin, “Interpolation-prediction networks for irregularly sampled time series,” arXiv preprint arXiv:1909.07782, 2019.
[17] S. Tipirneni and C. K. Reddy, “Self-supervised transformer for sparse and irregularly sampled multivariate clinical time-series,” ACM Transactions on Knowledge Discovery from Data (TKDD), vol. 16, no. 6, pp. 1–17, 2022.
[18] Y. Lou, Y. He, R. Zhang, Y. Cao, H. Wang, and Y. Huang, “Multitasks-based deep evidential fusion network for blind image quality assessment,” in Proceedings of the AAAI Conference on Artificial Intelligence, vol. 40, no. 9, 2026, pp. 7512–7520.
[19] Y. Lou, D. Xu, R. Zhang, J. Zhang, Y. Cao, H. Wang, and Y. Huang, "Mr image quality assessment via enhanced mamba: A hybrid spatial-frequency approach," in 2024 IEEE International Conference on Bioinformatics and Biomedicine (BIBM). IEEE, 2024, pp. 3561–3564.
[20] A. Radford, J. W. Kim, C. Hallacy, A. Ramesh, G. Goh, S. Agarwal, G. Sastry, A. Askell, P. Mishkin, J. Clark et al., “Learning transferable visual models from natural language supervision,” in International conference on machine learning. PmLR, 2021, pp. 8748–8763.
[21] J. Li, R. Selvaraju, A. Gotmare, S. Joty, C. Xiong, and S. C. H. Hoi, “Align before fuse: Vision and language representation learning with momentum distillation,” Advances in neural information processing systems, vol. 34, pp. 9694–9705, 2021.
[22] S. N. Shukla and B. M. Marlin, “Integrating physiological time series and clinical notes with deep learning for improved icu mortality prediction,” arXiv preprint arXiv:2003.11059, 2020.
[23] J. E. A. Ovalle, T. Solorio, M. Montes-y Gómez, and F. A. González, “Gated multimodal units for information fusion.” in ICLR (Workshop), vol. 5, 2017, pp. 5–4.
[24] X. Zhang, S. Li, Z. Chen, X. Yan, and L. R. Petzold, “Improving medical predictions by irregular multimodal electronic health records modeling,” in International conference on machine learning. PMLR, 2023, pp. 41300–41313.
[25] A. Vaswani, N. Shazeer, N. Parmar, J. Uszkoreit, L. Jones, A. N. Gomez, L. Kaiser, and I. Polosukhin, “Attention is all you need,” Advances in neural information processing systems, vol. 30, 2017.
[26] E. Alsentzer, J. Murphy, W. Boag, W.-H. Weng, D. Jindi, T. Naumann, and M. McDermott, “Publicly available clinical bert embeddings,” in Proceedings of the 2nd clinical natural language processing workshop, 2019, pp. 72–78.
[27] B. Hui, J. Yang, Z. Cui, J. Yang, D. Liu, L. Zhang, T. Liu, J. Zhang, B. Yu, K. Lu et al., “Qwen2. 5-coder technical report,” arXiv preprint arXiv:2409.12186, 2024.
[28] A. E. Johnson, L. Bulgarelli, L. Shen, A. Gayles, A. Shammout, S. Horng, T. J. Pollard, S. Hao, B. Moody, B. Gow et al., “Mimiciv, a freely accessible electronic health record dataset,” Scientific data, vol. 10, no. 1, p. 1, 2023.
[29] E. W. Ely, S. K. Inouye, G. R. Bernard, S. Gordon, J. Francis, L. May, B. Truman, T. Speroff, S. Gautam, R. Margolin, R. P. Hart, and R. Dittus, “Delirium in mechanically ventilated patients: Validity and reliability of the confusion assessment method for the intensive care unit (CAMICU),” JAMA, vol. 286, no. 21, pp. 2703–2710, 2001.
[30] J. A. Hanley and B. J. McNeil, “The meaning and use of the area under a receiver operating characteristic (roc) curve.” Radiology, vol. 143, no. 1, pp. 29–36, 1982.
[31] J. Davis and M. Goadrich, “The relationship between precision-recall and roc curves,” in Proceedings of the 23rd international conference on Machine learning, 2006, pp. 233–240.
[32] T. Saito and M. Rehmsmeier, “The precision-recall plot is more informative than the roc plot when evaluating binary classifiers on imbalanced datasets,” PloS one, vol. 10, no. 3, p. e0118432, 2015.
[33] W. B. Glenn et al., “Verification of forecasts expressed in terms of probability,” Monthly weather review, vol. 78, no. 1, pp. 1–3, 1950.
[34] K. Cho, B. Van Merriënboer, C. Gulçehre, D. Bahdanau, F. Bougares, H. Schwenk, and Y. Bengio, “Learning phrase representations using rnn encoder-decoder for statistical machine translation,” in Proceedings of the 2014 conference on empirical methods in natural language processing (EMNLP), 2014, pp. 1724–1734.
[35] Y. Yang, “Clmn: Concept based language models via neural symbolic reasoning,” in 2025 IEEE International Conference on Systems, Man, and Cybernetics (SMC). IEEE, 2025, pp. 795–801.
[36] Z. Wang, J. Hu, and R. Mu, “Safety of embodied navigation: A survey,” arXiv preprint arXiv:2508.05855, 2025.
[37] Z. Wang, G. Jin, J. Hu, and R. Mu, “Clucert: Certifying llm robustness via clustering-guided denoising smoothing,” in Proceedings of the AAAI Conference on Artificial Intelligence, vol. 40, no. 44, 2026, pp. 37998–38006.