arXiv:2610.24811cs.CVOct 2026

Manuscript Offprint

arXiv:2610.24811

Directionally Factorized Illumination with Spherical Harmonic Rotation

Yimeng Dou, Adam M. Saunders, Andre T. S. Hucke, Michael E. Kim, Adam W. Anderson, Eric R. Tkaczyk, Bennett A. Landman, Daniel Moyer

Yimeng Dou 1^{1}, Adam M. Saunders 1^{1}, Andre T. S. Hucke 1^{1}, Michael E. Kim 2^{2}, Adam W. Anderson 3−5^{3-5}, Eric R. Tkaczyk 1,3,6,7^{1,3,6,7}, Bennett A. Landman 1−5^{1-5}, Daniel Moyer 2^{2}

Abstract—Many real-world capture scenarios involve an active light source rigidly attached to the camera: camera flashes for dark-environment imaging, underwater vehicle lights, and endoscopic/laparoscopic medical procedures. As the camera moves, the co-mounted light moves with it, causing the illumination direction at each surface point to change across views. Neural rendering methods (NeRF, Gaussian Splatting) encode this pose-dependent illumination as surface coloration, producing appearance inconsistencies and making it harder to recover the underlying scene. We present DaFISH, which can be plugged into any novel-view synthesis (NVS) pipeline such as NeRF. It factorizes per-point emitted color into surface albedo and a spherical harmonic (SH)-represented illumination factor. During training, the SH illumination is evaluated directly, enabling stable joint optimization of albedo, lighting, and geometry. DaFISH provides analytical generalization of illumination to arbitrary camera poses without retraining. Building on the closed-form SH-to-irradiance conversion, the training pipeline is fully differentiable from SH evaluation through volume rendering. Averaged over the held-out frames of the five scenes, DaFISH attains the best mean PSNR (38.91 dB), SSIM (0.9613), and LPIPS (0.0582) among all compared methods. It improves over the strongest splatting baseline as well as the closest NeRF-based baseline, while recovering the scene consistently across views compared to prior methods.

I. INTRODUCTION

Neural radiance fields (NeRF) [4], [5] and Gaussian Splatting (GS) [6], [7] have transformed novel view synthesis (NVS) and 3D scene reconstruction. However, both assume a static scene under static illumination, where the radiance emitted from a surface point is modeled as a fixed function of position and viewing direction. The incident illumination L is treated as a fixed function of world coordinates, independent of camera pose or acquisition time.

Under active illumination, the image-capture scenario violates this assumption. Whenever the light is attached to the camera, or the object moves relative to a stationary camera and light, the illumination is fixed in the camera frame, so

(a) Robots operating in the dark with onboard lights

Figure

SubT challenge

Figure

Deep Water Survey

Figure

Nighttime Driving

(b) Problem Setup

Standard NVS

Figure

Light fixed, Constant lighting

Coupled camera-light capture

Figure

Pose 1

Pose 2

Pose 3

Illumination travels with the camera

Illumination via irradiance:

E(n)=∫L(ω)(ωi⋅n)+ dωiE(\mathbf{n}) = \int L(\omega)(\omega_i \cdot \mathbf{n})_+ \, d\omega_i

(c) Results

Ground Truth

Figure

DaFISH

Figure

Recovered Illumination

Figure

Fig. 1. (a) Robots that operate in dark environments, such as subterranean exploration (SubT challenge) [1], deep-water surveys by the remotely operated vehicle Hercules [2], and nighttime driving [3] rely on onboard lights that move with the platform. (b) In standard novel view synthesis (NVS, left), hundreds of images are captured while the camera moves around the scene under fixed illumination field L, and a radiance field is reconstructed with methods such as NeRF, 3DGS, or their derivatives. However, in co-located capture (right), the camera and a light source are rigidly attached, so the surface illumination changes with every pose, as the light source is moving as well. We model this moving illumination through the irradiance E(n)E(\mathbf{n}), so the irradiance for a given normal is computed by analytically rotating the coefficients with a Wigner-D matrix of the known camera motion, where the residual spatial variation from the near-field source is absorbed by a learned per-sample MLP (see III for more details). (c) DaFISH can reconstruct the scenes while attributing frame-varying brightness to the illumination branch. The brightness of ground truth and rendered images is increased by 40% for visualization.

in the scene’s frame the light moves with every pose. In direct lighting capture, the light source is rigidly attached to the camera for imaging in dark, underwater, or enclosed spaces [1], [8], [9], [10]. We call this the co-located (or comoving [9], [10]) lighting configuration.

Standard neural rendering lacks a mechanism to distinguish variation in local appearance due to change in illumination. This becomes a problem under a co-located light source, in which bright and dark regions occur together, as shown in Fig. 1. In such cases, as the camera repositions, the irradiance it produces on the scene shifts with every camera motion, while its angular emission profile is constant in the camera frame. As a result, each image exhibits strong,

*This work was supported by the National Institutes of Health under award numbers U54DK134302, U54EY032442, R01EB017230, R01HL169944. This work was also partially supported by VA MERIT award I01 CX002721 from the United States Department of Veterans Affairs Clinical Science R&D Service, and by the Alzheimer's Disease Sequencing Project Phenotype Harmonization Consortium (ADSP-PHC) that is funded by NIA (U24 AG074855, U01 AG068057 and R01 AG059716).

1^{1} Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN, USA; 2^{2} Department of Computer Science, Vanderbilt University, Nashville, TN, USA; 3^{3} Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA; 4^{4} Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA; 5^{5} Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; 6^{6} Department of Dermatology, Vanderbilt University Medical Center; 7^{7} Veterans Affairs Tennessee Valley Healthcare System spatially localized appearance variations due to the light's pose relative to the scene surface, and the same 3D point may display entirely different colors in different views due to illumination changes. This breaks the multi-view photometric consistency that standard neural rendering relies on, leading to reconstruction artifacts.

Recent work has proposed solutions to this NVS problem. Many of these approaches construct explicit lighting or model constraints [8], [11], [12], [13]. Other methods, like [14], make strong physical assumptions about camera or light behavior. Luminance-GS [15] uses global per-view tone curves to handle challenging lighting conditions but cannot model spatially varying illumination across an image plane. Gaussian in the Dark [16] resolves cross-view brightness inconsistency in dark captures but attributes it to the camera imaging characteristics.

In contrast to these approaches, we propose a formulation (DaFISH) that exploits the known rigid coupling between camera and light. As illustrated in Fig. 2, we decompose the rendered color into an intrinsic albedo and an illumination field with irradiance, and we parameterize the irradiance in low-order spherical harmonics (SH), an orthonormal basis for functions on the sphere. The key insight, established by [17], [18], is that the irradiance of a Lambertian surface is a smooth, low-order function of the normal and is well approximated by a small number of coefficients. Also, rotating a function on the sphere acts linearly and bandwise on its SH coefficients via the Wigner-D matrices [19], [20]. So, the irradiance for a given normal is obtained by an analytic Wigner-D rotation of the coefficients rather than by re-integrating over the hemisphere. This is general, only assuming a co-located lighting function, instead of a specific lighting geometry and target scene, and further does not require a well-lit reference frame. Like [10], [21], it requires no calibration target and no separate calibration capture.

Our main contributions can be summarized as follows: (1) We formulate an NVS rendering method for the colocated light setting as a factorization of color into albedo and a illumination field with directional SH irradiance carried across frames by an analytic Wigner-D rotation of the known camera motion. (2) We present experiments on synthetic and real co-located captures that demonstrate better novel view reconstruction quality. (3) The formulation requires no calibration target and no separate calibration capture, making it applicable to captures already collected in the field.

References (33)