Manuscript Offprint

arXiv:2608.25630

SeVeR: Selective Visual Exposure and Retrieval for 3D Medical Image Question Answering

Yaojun Hu, Danyang Tu, Yang Liu, Jiajin Zhang, Wei Fang, Zhiqiang Liu, Chunlai Dong, Yingda Xia, Haochao Ying, Jian Wu, Ling Zhang

Yaojun Hu 1,2,5,6,7,∗^{1,2,5,6,7,*}, Danyang Tu 1,3,∗,‡^{1,3,*,\ddagger}, Yang Liu 1,∗^{1,*}, Jiajin Zhang 1,3,†^{1,3,\dagger}, Wei Fang 1,3^{1,3}, Zhiqiang Liu 2^{2}, Chunlai Dong 2,5,6,7^{2,5,6,7}, Yingda Xia 1^{1}, Haochao Ying 4,5,6†^{4,5,6\dagger}, Jian Wu 2,5,6,7^{2,5,6,7}, Ling Zhang 1^{1}

1^{1}DAMO Academy, Alibaba Group

2^{2}College of Computer Science and Technology, Zhejiang University

3^{3}Hupan Lab

4^{4}School of Public Health, Zhejiang University

5^{5}State Key Laboratory of Transvascular Implantation Devices and TIDRI, Zhejiang University

6^{6}The Second Affiliated Hospital and Liangzhu Laboratory, Zhejiang University School of Medicine

7^{7}Zhejiang Key Laboratory of Medical Imaging Artificial Intelligence

*Equal contribution, ‡Project leader, †Corresponding author

Volumetric medical VQA requires reasoning over long and redundant 3D visual token sequences, especially in multi-sequence MRI where complementary modalities provide diverse diagnostic cues but expose the decoder to many repeated anatomical regions. To investigate reasoning under multi-sequence visual redundancy, we first introduce BreMRIs-VQA, a clinically curated breast MRI benchmark with 1.19M QA pairs from 71.0K sequences and 12.9K patients, covering both free-text and multiple-choice questions. We further propose SeVeR, a selective visual exposure framework that compresses dense volumes into modality-wise prototypes and retrieves complementary multi-level evidence with change-aware gated attention during decoding, trained with a marginal-utility self-consistency objective that suppresses unhelpful retrieval. Experiments on BreMRIs-VQA and public benchmarks show that SeVeR improves both discriminative and generative performance while exposing substantially fewer visual tokens.

DAMO

TECH TO THE FUTURE

1 Introduction

Medical Visual Question Answering (VQA) is evolving from recognition in single images to answering clinically grounded queries over complex imaging studies Li et al. (2023); Lin et al. (2025); Xu et al. (2025). This challenge is particularly pronounced in volumetric MRI, where diagnosis depends on integrating complementary evidence across multiple sequences. For example, a lesion with suspicious enhancement on dynamic contrast-enhanced MRI may be interpreted differently after considering its T2-weighted signal and diffusion restriction pattern Minhas and Oliver (2022). Therefore, an effective medical VQA model needs to integrate complementary evidence distributed across multi-sequence 3D images. However, existing methods Hamamci et al. (2024); Wu et al. (2025); Bai et al. (2024) still predominantly rely on single-modal inputs, overlooking the complementary interactions inherent in multi-sequence MRI.

In this paper, we try to advance existing single-modality-based medical VQA methods to the multi-modal scenario, allowing a better alignment with clinical practice. To this end, two challenges have emerged: 1) Scarcity of multi-modality-based medical VQA datasets: due to the inherent inaccessibility of medical data and the requirement for clinical expertise in designing multi-modality based question-answer (QA) pairs, existing medical VQA datasets Gai et al. (2025); Chen et al. (2025), typically contain only single-modal image and thus feature relatively limited types of QA pairs; 2) Redundant visual exposure: in multi-modal scenario, images of different modalities contain complementary diagnostic signals while simultaneously sharing extensive common regions, leading to the challenge of signal dilution Chen et al. (2024); Bolya et al. (2023); Yang et al. (2025b), i.e., salient findings in one single modality may be overwhelmed by repetitive background patterns of all other modalities.

Figure

(a) Distribution of MRI Modalities in BreMRIs-VQA

(b) Task Distribution of BreMRIs-VQA

Question: Based on MRI T1-weighted, T2-weighted, and ADC images, what is this patient's BI-RADS category?

(c) Overview of SeVeR Architecture

Answer: The patient's BI-RADS category is 4A for the left breast and 3 for the right breast.

(d) Multiple-choice Task Performance

Global Background Assessment

(e) Free-text Task Performance

Figure 1 Overview of the BreMRIs-VQA benchmark and the proposed SeVeR. (a–b) BreMRIs-VQA contains 6 MRI modalities and 7 categories of clinical tasks derived from 1.19M QA pairs. (c) Architecture of SeVeR, which integrates Greedy Prototype Selection, Change-aware Gated Attention, and Self-Consistency Regularization. (d–e) SeVeR's superior performance in multiple-choice and free-text generation tasks.

To tackle the data challenge, we first built BreMRIs-VQA, a large-scale, clinically curated multi-modal medical VQA benchmark dataset. We collected 71.0K breast MRI sequences from a cohort of 12.9K patients, where each contains at least 3 different MRI modalities, paired with a radiology report and a pathology report verified by two radiologists. Then, we design a QA generation pipeline consisting of multi-stage extraction, task construction, paraphrasing, and validation, which enables BreMRIs-VQA to contain 1.19M VQA pairs, including 671.6K free-text pairs and 515.1K multiple-choice pairs. The benchmark covers seven workflow-grounded task groups, enabling evaluation of both generative reasoning and discriminative clinical decision making. Fig. 1 (a) illustrates the number of 6 MRI modalities (T1-STIR, T1w, DCE, T2w, DWI and ADC) included the dataset, while Fig. 1 (b) depicts totally 7 VQA task categories ranging from fine-grained lesion characterization to holistic diagnosis.

We further propose SeVeR, a selective visual exposure framework for multi-sequence medical VQA, as shown in Fig. 1 (c). SeVeR first applies Greedy Prototype Selection (GPS) to compress dense volumetric tokens into compact modality-wise prototypes that preserve global coverage while suppressing repeated visual content. Since fixed prototypes may miss question-specific details, SeVeR maintains a multi-level feature bank and uses Change-aware Gated Attention (CaGA) to retrieve complementary evidence during decoding. This design separates two roles: GPS provides a compact visual memory before decoding, while CaGA performs question-dependent evidence retrieval through the language-conditioned decoder states. To avoid degenerate always-on retrieval, we introduce Self-Consistency Regularization with Marginal Utility (SCR-MU), which penalizes retrieval when it fails to improve task loss over a retrieval-disabled baseline. Figs. 1 (d) and (e) provide an overview of the resulting gains across multiple-choice and free-text clinical tasks.

Our contributions are threefold. First, we introduce BreMRIs-VQA, a large-scale multi-sequence breast MRI VQA benchmark with workflow-grounded free-text and multiple-choice questions from expert verified clinical reports. Second, we propose SeVeR, which initially selects compact representative visual prototypes and dynamically retrieves fine-grained evidence via change-aware attention gates with a marginal-utility self-consistency objective that prevents collapsing to trivial behaviors. Finally, extensive experiments on

Figure

Figure 2 Dataset construction pipeline. The top-right pie chart depicts hierarchical clinical attribute distribution.

BreMRIs-VQA and public 3D benchmarks validate the effectiveness of the proposed framework across discriminative and generative tasks.

References (30)