Manuscript Offprint

arXiv:2610.25211

NeuroAct: Advancing EEG Analysis and Decoding via Dual-Loop Autonomous Research

Wei Xiong, Jiangtong Li, Han Zhao, Linxiao Yang, Jie Li, Changjun Jiang

ABSTRACT

EEG analysis and decoding underpin brain-computer interfaces, cognitive assessment, and sleep monitoring. Fixed pipelines and reward-driven search do not explicitly determine how signal structure, representations, predictor behavior, and training dynamics contribute to performance or generalization gaps, leaving intervention choice underdetermined. We introduce NeuroAct, an autonomous research agent framework for EEG analysis and decoding. NeuroAct implements dual-loop autonomous research across EEG foundation models, task-specific predictors, and model combinations. In an inner loop, research, development, and review roles use evidence on signal structure, representations, predictor behavior, and training dynamics to test hypotheses, select analyses or interventions, and refine candidates using performance, stability, and cost feedback. An outer loop distills outcomes into conditional, testable recommendations with task and model conditions, then validates and revises them on subsequent tasks. We evaluate four settings: (A) EEG General Analysis, (B) Cross-task Model Optimization, (C) Single-task Open Research, and (D) Collaborative Prediction. In Setting A, NeuroAct's 80.88 macro-average exceeds BrainAgent's 63.13 by 17.75 points. In Setting B, NeuroAct raises EEGPT's mean balanced accuracy (BA) by 7.34 points and HBN Pearson's r from 0.6894 to 0.7362; in Setting C, it improves ADFTD BA by 16.33 points; and in Setting D, it raises Workload BA from 79.69% to 85.02%. Experience reuse raises BCIC-IV-2a BA from 34.66% to 50.81% while reducing LLM tokens by 64.02%, indicating recommendations improve cross-task performance. NeuroAct enables evidence-guided EEG research improved by cross-task experience.

1 INTRODUCTION

EEG analysis and decoding support cognitive-state assessment, sleep monitoring, and brain-computer interfaces. Pretrained EEG foundation models (EEG-FMs) provide reusable representations across diverse tasks (Jiang et al., 2024; Wang et al., 2024a; 2025a; El Ouahidi et al., 2025; Döner et al., 2026). Effective task adaptation requires assessing how signal structure, representations, predictor behavior, and training dynamics contribute to performance or generalization gaps, then selecting evidence that distinguishes competing explanations. Fixed pipelines and reward-driven optimization do not make this diagnostic decision explicit, motivating an autonomous research agent that improves within-task EEG decoding and refines research strategies across tasks.

Task-specific EEG analysis must connect signal structure to how a model represents, predicts, and learns. Benchmark studies show model rankings and transfer depend on task and readout design, encoded features can differ from those used for prediction, and token preservation affects frozen-encoder decoding (Tang et al., 2026; Širca et al., 2026). When refinement of a single EEG model yields diminishing gains, this diagnosis can test whether other models correct its errors on samples. Error overlap determines whether complementary prediction merits a model-combination experiment.

Autonomous research systems combine hypothesis generation, experimentation, and interpretation in continuous workflows (Lu et al., 2026). Model-development systems further use experimental feedback or accumulated experience to revise their approaches (alphaXiv, 2026). In the EEG domain, BrainAgent orchestrates analysis tools (Zhou et al., 2026b), BrainPilot combines domain knowledge

Table 1: EEG analysis, decoding, and research guidance across agent frameworks (Wang et al., 2024c; Zhou et al., 2026b; Li et al., 2026a; Wang et al., 2026). ✓: supported; ●: partial; —: unspecified.

Scope / mechanismCodeActBrainAgentBrainPilotNeuroWeaverNeuroAct
Primary scopeGeneral codingSignal analysisBrain researchPipeline searchAnalysis & decoding
Research actions
Code generation & execution✓—✓✓✓
EEG analysis workflows—✓✓●✓
Model editing & training✓—✓✓✓
EEG-FM adaptation & fine-tuning————✓
Joint multi-task training————✓
Model combination————✓
Feedback and experience
Representation & gradient analysis——✓—✓
Feedback-based iteration✓●✓✓✓
Progressive capability disclosure——✓—✓
Cross-task experience revision————✓

and research skills (Li et al., 2026a), and NeuroWeaver searches task pipelines (Wang et al., 2026). For EEG research, open questions concern how diagnostics guide interventions across foundation-model adaptation, task-specific modeling, joint training, and model combination, and how cross-task validation and revision make conditional recommendations useful on subsequent tasks.

We introduce NeuroAct, an autonomous research agent framework for EEG analysis and decoding. NeuroAct implements a dual-loop autonomous research framework: an inner loop selects analyses and interventions from evidence on signal structure, representations, predictor behavior, and training dynamics, while an outer loop distills, validates, and revises conditional recommendations or experiences across research tasks. Within the inner loop, the Coordinator directs the Researcher, Developer, and Reviewer to test competing diagnostic hypotheses through executable analyses or model changes, with predictive performance, stability, and cost informing the next action for each task. Each experience item is a conditional recommendation that records applicable EEG task and model conditions, a proposed action, supporting and counterevidence, and reassessment conditions. Subsequent tasks test its utility, while counterevidence narrows, suspends, or replaces the recommendation. Tab. 1 positions this scope relative to existing agent frameworks.

We organize NeuroAct's evaluation around four research settings: (A) EEG General Analysis, (B) Cross-task Model Optimization, (C) Single-task Open Research, and (D) Collaborative Prediction. The evaluation covers six datasets (HBN (Alexander et al., 2017; Shirazi et al., 2024), Workload (Zyma et al., 2019), PhysioMI (Schalk et al., 2004), BCIC-IV-2a (Tangermann et al., 2012), ADFTD (Miltiadous et al., 2023), and HMC (Alvarez-Estevez & Rijsman, 2021)), three LLM backend families (DeepSeek-V4 Flash (DeepSeek-AI et al., 2026), GPT-5.6 Luna (OpenAI, 2026), and Qwen3.8 Flash Next (Qwen Team, 2026)), and the available external baselines CodeAct (Wang et al., 2024c), BrainPilot (Li et al., 2026a), and BrainAgent (Zhou et al., 2026b). With DeepSeek-V4 Flash, NeuroAct reaches an 80.88 macro-average score in Setting A and exceeds 75 with Luna and Qwen on BrainBench (Zhou et al., 2026a). In Setting B, NeuroAct raises mean balanced accuracy (BA) from 47.50 to 54.84 and HBN Pearson's rr from 0.6894 to 0.7362. NeuroAct gains 16.33 BA points on ADFTD in Setting C and raises Workload BA from the best single model's 79.69% to 85.02% in Setting D. Experience reuse transfers a PhysioMI-derived recommendation to BCIC-IV-2a, raising test BA from 34.66% to 50.81% while reducing LLM tokens by 64.02%. Our contributions are:

• Evidence-guided inner-loop EEG research. NeuroAct tests alternatives and selects analyses or interventions using signal, representation, predictor, and training evidence.

  • Outer-loop conditional strategy improvement. NeuroAct tests conditional recommendations across tasks and revises them using matched performance and cost comparisons when warranted.

  • Executable EEG analysis and decoding. NeuroAct operationalizes evidence through EEG General Analysis, Cross-task Model Optimization, Single-task Open Research, and Collaborative Prediction.

References (100)

Couldn't load all references. Reload the page to try again.