arXiv:2610.25426cs.ROOct 2026

Manuscript Offprint

arXiv:2610.25426

SurGPT: A Multi-Task Foundation Model for Robotic Surgical Skills Assessment and Gesture Recognition

Parham M. Kebria, Saeid Nahavandi, Mehrdad Saif, Fernando Bello

Parham M. Kebria, Saeid Nahavandi, Mehrdad Saif, and Fernando Bello

Abstract—The assessment of surgical skills in robotic surgery training has traditionally relied on subjective evaluations by human experts, creating bottlenecks in surgical education and limiting scalability. We present a novel foundation model that automatically analyzes robotic surgical videos to provide comprehensive skill assessment and gesture understanding. Combining a visual encoder with a transformer architecture, the model performs three key tasks simultaneously: 1) surgical task classification (knot tying, needle passing, suturing), 2) skill level assessment on a standardized scale, and 3) natural language generation of surgical gesture descriptions. The model processes video sequences from the da Vinci surgical robot and generates human-readable text descriptions of surgical actions, similar to how language models generate text from prompts, using a multi-task learning framework with adaptive uncertainty weighting to optimize performance across all objectives. Our transformer-based architecture incorporates positional encoding for temporal understanding and attention mechanisms for spatial-temporal feature integration. Evaluated on the da Vinci Skills Simulator dataset, the proposed framework demonstrates state-of-the-art performance in surgical task recognition and provides interpretable skill assessments that correlate with expert evaluations, with the model's ability to generate natural language descriptions of surgical gestures opening new possibilities for automated surgical education, real-time feedback systems, and objective skill assessment in surgical training and certification programs.

Index Terms—Foundation Models, Multi-Task Learning, Robotic Surgery, Surgical Skills Assessment, Transformer Architecture, Video Understanding.

I. INTRODUCTION

The emergence of robotic systems in clinical and healthcare practices makes them a critical element in a variety of medical procedures [1]−[3][1]-[3]. Therefore, surgeons and clinicians need to learn, adapt, and practice the new technology. Employing all their skills, knowledge, and experience in this new schema of practice becomes a challenge, considering their limited time for training. This phenomenon requires a methodology to properly evaluate surgical skills in robotic practices [4][4]. Surgical skill assessment in robotic surgery training has traditionally relied on subjective evaluations by human experts, creating bottlenecks in education and restricting scalability [5][5]. However, such expert-driven evaluations are time-intensive, costly, and inherently inconsistent, as they are susceptible to variability and human bias [6][6], [7][7].

Recent advances in deep learning have significantly expanded the scope of surgical scene understanding, shifting from handcrafted features and task-specific models toward end-to-end learning frameworks. In particular, transformer-based architectures have emerged as a powerful paradigm for modeling long-range temporal dependencies and complex spatiotemporal interactions in surgical videos [8]. By leveraging self-attention mechanisms, transformers can capture both local motion patterns and global procedural context, enabling a more holistic understanding of surgical scenes compared to traditional sequential models.

The foundation model paradigm enables transfer learning across different surgical procedures and institutions, potentially revolutionizing surgical education through scalable, objective, and consistent skill evaluation [9]. Toward this paradigm, a wide range of techniques have been investigated to utilize expert human demonstrations to provide data-driven models with the vast amount of knowledge and context of the target procedures [10]–[12]. Surgical scene understanding introduces advanced machine learning and deep learning techniques used in image processing in the context of surgical procedures. This includes instrument detection, instrument-tissue segmentation, instrument tracking, instrument pose estimation, and tissue classification, to name a few [13]. Foundation models have shown promising performance in precision and effectiveness in the analysis of medical images and anatomical information [14].

Despite these advances, there are still drawbacks and challenges in the deployment of foundation models in clinical applications that have not yet been investigated. Being large in size with the corresponding large number of parameters, foundation models are extremely data-thirsty. However, the privacy of healthcare data is a major concern, which limits the accessibility of large enough medical datasets for training such models [15][15]. On the other hand, the lack of interpretability and explainability in these deep models poses significant challenges to their adoption in clinically critical applications [16][16]. Still, foundation models provide novel benefits in the field, such as integrating multi-modal data to obtain more comprehensive diagnosis decisions [17][17]. Specifically, extracting diagnostic information from clinical videos is one of the areas where foundation models demonstrate unmatched benefits [18][18].

Moreover, surgical videos are characterized by high variability due to differences in anatomy, surgeon style, viewpoint, and occlusions, while annotated datasets remain limited and costly to obtain. Specifically, for clinical adoption, surgical scene understanding systems must provide interpretable and reliable outputs that align with expert reasoning. Transformer-based foundation models, particularly when coupled with interpretable outputs such as natural language descriptions, represent a promising direction for addressing these challenges and advancing automated, scalable, and clinically meaningful surgical intelligence systems. Existing surgical AI methods are often designed for single tasks, which limits transfer across related clinical objectives. They also provide limited inter-

P. M. Kebria is with the Electrical and Computer Engineering Department, North Carolina A&T State University, Greensboro, NC, USA, and also with Swinburne University of Technology, Hawthorn, VIC, Australia. (This work was done with Swinburne University of Technology.)

S. Nahavandi is with Swinburne University of Technology, Hawthorn, VIC, Australia, and also with Harvard Paulson School of Engineering and Applied Sciences, Harvard University, Allston, MA, USA.

M. Saif is with the Department of Electrical and Computer Engineering, University of Windsor, Windsor, Ont. Canada.

F. Bello is with Imperial College London, London, United Kingdom, and also with Duke-NUS Medical School, Singapore.

Corresponding author: pkebria@swin.edu.au pretability and rarely use uncertainty as an adaptive learning signal, reducing trust and robustness.

Motivated by prior limitations, we propose a unified multi-task foundation model for robotic surgical video analysis that jointly performs gesture recognition and real-time skill assessment, combining a visual encoder and transformer for shared spatiotemporal reasoning, improved interpretability, and adaptive uncertainty weighting for better generalization and reliability. The main contributions of this work are summarized as follows:

• Automated surgical task recognition: We propose a unified framework that accurately identifies core robotic surgical tasks, including knot tying, needle passing, and suturing, directly from video sequences.

• Objective surgical skill assessment: The model provides a standardized and scalable evaluation of surgical skill levels, producing objective proficiency scores that correlate strongly with expert assessments.

• Interpretable gesture understanding via natural language generation: We introduce a novel capability for generating human-readable textual descriptions of fine-grained surgical gestures from video data, improving interpretability and supporting automated feedback and educational applications.

The model processes video sequences captured from the da Vinci surgical robot and produces human-readable textual explanations of surgical actions, analogous to prompt-driven language generation in large language models. A multi-task learning strategy with adaptive uncertainty weighting is employed to balance and optimize performance across all objectives. The transformer architecture incorporates positional encoding to capture temporal dynamics and attention mechanisms for effective spatiotemporal feature integration. Extensive evaluation on the da Vinci Skills dataset [19], [20] demonstrates that the model achieves state-of-the-art performance in surgical task recognition, while providing interpretable skill assessments that closely correlate with expert evaluations. Moreover, its ability to generate natural language descriptions of surgical gestures introduces new opportunities for automated surgical education, real-time feedback, and objective skill assessment in robotic surgery training and certification programs.

References (21)