arXiv:2610.25460eess.IVOct 2026

Manuscript Offprint

arXiv:2610.25460

Reliability-Preserving Compression for Deployable Medical Image Segmentation

Sagar Kumar, Shailja Sharma, Tirthajit Baruah, Punit Rathore

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Post-training compression of pretrained medical segmentation models commonly uses quantization, pruning, or distillation to reduce model size and computational cost. Existing medical segmentation quantization studies mainly evaluate Dice, model size, memory, and latency, but this is incomplete for safety-critical use because compressed models should also preserve uncertainty signals that indicate unreliable predictions. We study this problem in compressed MRI/CT segmentation and formalize why Dice can remain stable while uncertainty changes. Motivated by this failure mode, we propose score-guided aggregate-validated mixed precision (SGAV-MP), a post-training compression framework that selects layer precisions under reliability constraints. SGAV-MP ranks quantization actions with a compact benefit-risk score and accepts them only after full-model reliability validation on a calibration set. Across five 2D backbones and three 3D benchmarks, SGAV-MP preserves FP32-level Dice and high uncertainty-map agreement, achieving 3.59×−7.8×3.59\times -7.8\times compression in 2D and 4.73×−7.82×4.73\times -7.82\times in 3D. We also report backend-supported TensorRT deployment measurements separately to distinguish runtime execution from reliability-preserving storage compression.

1. Introduction

Medical image segmentation has been dominated by U-Net-style architectures and their extensions. U-Net-style CNNs, nnU-Net, transformer-based architectures, and promptable medical segmentation models, have achieved strong performance across medical imaging modalities [11, 17, 28, 36]. However, these models often operate on high-resolution images or volumetric scans. This makes deployment costly in memory, latency, and computation. This motivates compres-

Table 1. Representative cases where INT4 quantization may preserve usable Dice while degrading uncertainty and calibration. UQ Corr. denotes uncertainty-map correlation with the FP32 model.

DatasetModelDiceECEBrierUQ Corr.
PROMISE12EfficientNet-B00.8892→0.8820.8892 \rightarrow 0.8820.0982→0.1120.0982 \rightarrow 0.1120.196→0.220.196 \rightarrow 0.221.000→0.4281.000 \rightarrow 0.428
PROMISE12ResNet500.886→0.8810.886 \rightarrow 0.8810.103→0.1140.103 \rightarrow 0.1140.205→0.2290.205 \rightarrow 0.2291.000→0.3241.000 \rightarrow 0.324
MosMedPlusResNet500.785→0.6510.785 \rightarrow 0.6510.206→0.3650.206 \rightarrow 0.3650.412→0.7300.412 \rightarrow 0.7301.000→0.1191.000 \rightarrow 0.119

sion for practical use, while actual runtime gains depend on backend and hardware support.

Model compression reduces deployment cost through pruning, quantization, and distillation [10, 14, 18]. Post-training quantization (PTQ) is especially attractive because it can compress a pretrained model using only a small calibration set and without full retraining [25, 33]. This is useful in medical settings, where data access, annotation, and retraining can be expensive. Recent medical segmentation quantization methods, including EfficientQ [43], MedPTQ [35], and QMedSAM [27], report strong compression or deployment-related gains while preserving segmentation accuracy. However, their evaluation is mainly based on hard-mask accuracy and efficiency metrics such as Dice, HD95, model size, memory, and latency.

Accuracy-only evaluation is incomplete for safety-critical segmentation. A compressed model should not only predict a mask. It should also indicate when the prediction may be unreliable. Predictive uncertainty and calibration are important for ambiguous boundaries, low-contrast lesions, artifacts, small structures, domain shift, and out-of-distribution anatomy [16, 20, 29]. Table 1 shows the practical gap. INT4 quantization can leave hard-mask performance usable in some cases, while uncertainty correlation and calibration degrade substantially.

This paper asks:

Can a compressed medical segmenter preserve not only segmentation accuracy, but also uncertainty, calibration, and failure-detection behavior?

We address this question with score-guided aggregate-validated mixed precision (SGAV-MP), a post-training mixed-precision quantization framework for reliability-preserving compression. SGAV-MP ranks layer-precision actions using compression benefit, layer importance, and connection-aware risk, but accepts an action only if the complete compressed model satisfies aggregate reliability constraints on a calibration set. We report compression as the main objective and separately report backend-supported FP32/FP16/INT8 deployment-related measurements for representative 2D and 3D settings; mixed INT4/INT2 policies are treated as storage-compression policies unless directly supported by the backend.

Our contributions are:

• We show that compressed medical segmenters can preserve Dice while degrading calibration, uncertainty-map fidelity, and failure-detection behavior.

• We propose SGAV-MP, a post-training mixed-precision quantization method with full-model reliability validation before accepting compression actions.

• We evaluate reliability-preserving compression across medical segmentation datasets and models using segmentation, efficiency, calibration, uncertainty-preservation, failure-detection, and backend-supported INT8 deployment-related metrics.

References (38)