Manuscript Offprint
arXiv:2610.25546Ride, Raise, or Wake: A Theory of Light-Thread Placement on Multi-Tier Processors
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
Abstract
Phones and laptops now mix several kinds of cores, and each kind sits in its own voltage and clock domain. When a light thread arrives, should it run beside heavy threads on a fast cluster that is already awake, or wake a cluster of efficient cores? We answer with three costs. A thread can ride an awake domain at the voltage other threads hold, raise that voltage for everyone, or wake a sleeping domain and pay its fixed power. From these costs follows a simple rule: ride while the thread's demand is below , the fixed power of the cluster it would wake over the gap in energy per operation; otherwise wake the smallest tier that can serve it. The best tier is not monotone in demand: tiny threads ride high, medium threads wake a low tier, heavy threads go high again. Two common designs err on opposite sides of the rule: grouping a light thread with the heavy threads of its application overpays above the threshold, and an energy model without idle costs overpays below it. In a model with five tiers, grouping costs 80 to 145% more energy than the rule, and more as tiers are added. Measurements on an Apple M6 anchor the parameters.
1 Introduction
Phones and laptops now mix several kinds of cores. Apple’s M6 has efficiency, performance and super cores; Intel’s client parts add low-power efficiency cores; phone chips add a prime core. We call each kind a tier. Each tier sits in a voltage and clock domain, a cluster, and sometimes two tiers share one: on the M6 the performance and super cores share a cluster. A scheduler knows where a heavy thread belongs (a fast core) and where background work belongs (an efficient one). The hard case is the light thread, whose demand is small but not zero.
Where it runs matters. On the M6 we placed a light thread next to two busy threads of its own application. macOS ran it on the fast cluster, at the voltage the busy threads held, and it used 2.1 to 2.2 times the energy per operation it used when we launched it as an application of its own, which macOS ran on the efficiency cores. When the fast cluster had room to rise, the light thread raised its voltage for every thread there and paid up to 3.9 times. Yet riding a busy cluster is not always wrong: waking an idle cluster has a fixed price, and a thread light enough should not pay it.
We make this trade exact with a small model and three costs. A thread can ride an awake cluster at the operating point others hold, raise that point, or wake a sleeping cluster. Our contributions:
-
A threshold rule: ride while the demand is below , with a dimensionless form and a version for bursty threads (Section 3).
-
A structure theorem: the best tier is not monotone in demand, exactly when a larger tier is held awake by others while a cheaper one sleeps (Section 4).
-
Closed forms for many tiers and for the losses of two common policies, which err on opposite sides of the rule (Sections 4 and 5).
-
A five-tier model and anchors from measurements on an M6 (Section 6).
Parts of this are known. Android’s energy-aware scheduler and Qualcomm’s have charged for waking an idle cluster [16, 18], Linux has packed small tasks [8], Linux charges a thread for raising a domain [13], and Apple names the cost of riding a busy cluster a “passenger tax” [3]. What we add is the closed-form rule, the shape of the decision, and what the common policies lose.
Energy per operation. A busy core spends, per operation,
where c is the capacitance switched per operation, I the operations per cycle and the static power of a busy core. An idle core turns itself off.
Governor. A cluster runs at the clock its most demanding thread needs, , where is thread 's demand in operations per second and a utilization target: runs just fast enough, a smaller keeps headroom. macOS behaves like to 0.8 in our runs, and Linux's frequency governor uses 0.8 [11].
The light thread. The thread we place has demand r and gets a core of its own. The threads already in a cluster keep their work; at the cluster’s operating point they draw . Table 1 lists the symbols.
3 Ride, raise, or wake
PROPOSITION 1 (THREE COSTS). Adding the light thread to a core of design d in cluster C raises the power by
- ride, if C is awake and its clock already serves the thread ;
Bergach
Table 1: Symbols.
| demand of the light thread (operations per second) | |
|---|---|
| energy per operation of a busy core, (1) | |
| overhead power of an awake cluster | |
| utilization target of the governor | |
| energy per operation riding the busy cluster, and on the efficient cluster at its floor | |
| threshold demand | |
| : overhead over one core’s power | |
| : the passenger tax |
- raise, if is awake but must speed up, to and : ;
- wake, if is asleep, at and : .
PROOF. A cluster’s power is its threads’ power at the shared operating point plus its overhead. The three cases are the change before and after, depending on whether the operating point moves and whether the overhead was already paid.
The best place for the thread is where is least. The raise case is the one that is easy to forget: the term is paid by the other threads. To first order it is about , so a light thread that lifts a crowded cluster by a few percent of its voltage pays for everyone there.
PROPOSITION 2 (RIDE OR WAKE). Let cluster be awake with room for the thread, at energy per operation , and let cluster be asleep, with the thread fitting at ’s floor: energy and overhead . Riding costs less than waking if and only if
and always if .
PROOF. The two costs are and .
In units of cores the rule needs only two ratios. Let be what one core of serves at its floor, the overhead over that core’s power, and the passenger tax. Then
Riding pays only when the tax is small or the cluster to wake is costly next to one of its cores (Table 2). With the model’s M6 values (Section 6: on a performance core at the fast cluster’s top voltage, where we measured 206, and on an efficiency core at its floor), an overhead of 0.05 W gives , a few percent of an efficiency core.
Bursty threads. Proposition 2 assumes that the woken cluster stays awake while the thread lives. A thread that runs in bursts lets it sleep in between.
PROPOSITION 3 (BURSTY THREADS). Let the thread run bursts per second, and let cluster spend to wake up and fall asleep, and
Table 2: The threshold in cores of the efficient cluster, .
| tax | ||||
|---|---|---|---|---|
| 1.5 | 2 | 3 | 5 | |
| 0.1 | 0.20 | 0.10 | 0.05 | 0.03 |
| 0.3 | 0.60 | 0.30 | 0.15 | 0.07 |
| 1 | 2.00 | 1.00 | 0.50 | 0.25 |
stay awake for a time after each burst. If the gaps are longer than , riding costs less if and only if
PROOF. Waking costs : each burst pays the transition and the overhead for its busy time and its hold time.
Frequent small bursts should ride, rare large ones should wake. This is the break-even reasoning of dynamic power management [6], applied to placement. When the cluster never sleeps and Proposition 2 returns.
PROPOSITION 4 (RIDE OR RIDE). Between two awake clusters with room for the thread, the cheaper one is the one with the lower energy per operation at its current operating point, whatever the demand.
PROOF. Both costs are times a constant.
A large core held at a low voltage can therefore beat a small core held at a high one. Linux’s energy model already makes this comparison [13].
4 Which tier?
With one thread and nothing else running, the best tier rises with demand: small cores for light work, large ones for heavy work. This staircase follows from a standard argument whenever larger tiers gain on smaller ones as demand grows [14]. Busy clusters break it.
THEOREM 1. (a) If every cluster is asleep, or every cluster is awake at its own floor, the best tier is nondecreasing in demand (under the staircase condition above). (b) If a larger cluster is held awake by other threads while a smaller cluster with sleeps, and can serve more than , the best tier is not monotone in demand: below , a smaller tier above , and a tier at least as large as again for demand that no smaller tier can serve.
PROOF. (a) In both states each tier’s cost is its single-thread cost plus a constant (its own overhead when all clusters sleep, nothing when all are awake), and constants do not change how costs differ as grows, so the staircase stays. (b) The held cluster costs , with no constant; the sleeping one costs . Their difference, , grows with , so the order flips at (Proposition 2). Above what can serve, only larger tiers remain.
Fixed wake costs alone never break the staircase. What breaks it is a larger tier that other threads keep awake: its overhead is already paid, but its voltage is high.
Ride, Raise, or Wake

Figure 1: The best tier for a light thread on a five-tier processor while two heavy threads hold the top tier, T5, at its top clock. With the other tiers asleep, tiny threads ride T5; with T2 awake they ride T2; with every tier awake the choice rises with demand. Lines are offset slightly for legibility.
COROLLARY 1 (THE TOP TIER). The top tier is the right place for a light thread only if no cheaper cluster is awake with room and the thread is lighter than the wake threshold of the cheaper sleeping clusters, or if the thread is too heavy for every lower tier. A middle tier that is awake is the cheapest ride for every light thread below its own threshold.
Many tiers. Suppose energy per operation grows by a factor from one tier to the next at the same voltage ( is the square root of the area ratio under Pollack's rule). Riding tier at voltage instead of tier at its floor then costs per operation. For an adjacent tier awake at the same voltage , and the threshold is : with closely spaced tiers, light threads should ride the nearest awake tier rather than wake a smaller one.
Figure 1 shows an example built on the M6's designs (Section 6): T1 is smaller than the efficiency core, T2 is the efficiency core, T3 the performance core, T4 the super core and T5 larger, each in its own cluster, with overheads from 0.02 W (T1) to 0.2 W (T5). With the other tiers asleep, threads under 0.04 Gops/s ride T5, then each tier takes its turn as demand grows, and T5 returns for threads too heavy for T4. With T2 awake, light threads ride T2 up to 0.94 Gops/s. With every tier awake, the staircase returns.
5 Two policies, two errors
Two simple policies are in use. Grouping puts a light thread with the heavy threads of its application: macOS recommends a cluster per thread group and quality-of-service class, and an application's threads share a group by default [3, 4]. Ignoring idle costs puts it wherever energy per operation is lowest, as an energy model does when an idle cluster costs nothing. Mainline Linux removed idle costs from its energy model in 2018 [7]; in our reading of its code [12] an empty cluster is free, so it never rides.
PROPOSITION 5 (WHAT EACH POLICY LOSES). In the setting of Proposition 2, always riding loses nothing below and above it; its cost over the optimum, , rises toward the tax . Always waking loses below and nothing above it; its ratio grows without bound as , but its loss never exceeds . For demand spread evenly in log scale over ,

Figure 2: What the two policies pay over the optimum on the M6 numbers ( pJ, pJ, W, so Gops/s and ).
Table 3: Grouping against the rule, for demand from 0.02 to 8 Gops/s, on ladders of tiers whose top tier two heavy threads hold at its top clock; “top tier best” is the share of demands for which riding the top tier is right.
| TiersK | Others asleep | Middle awake grouping costs | |
|---|---|---|---|
| grouping costs | top tier best | ||
| 2 | +80% | 34% | n/a |
| 3 | +129% | 17% | +330% |
| 4 | +144% | 13% | +328% |
| 5 | +145% | 13% | +382% |
with , the mean ratios are
ride:
wake:
PROOF. The losses follow from Proposition 2; the means integrate them against .
The two policies err on opposite sides of (Figure 2). Grouping overpays for every thread heavier than , by up to the tax; ignoring idle costs overpays for every thread lighter than , by up to the overhead it ignores. For demand between 0.05 and 5 Gops/s, they use and more energy than the rule on average.
More tiers make grouping worse (Table 3). For ladders of two to five tiers spanning the same designs, with two heavy threads holding the top tier at its top clock, grouping costs 80 to more than the rule when the other tiers sleep, and over when a middle tier is awake. Each new tier is one more cheap place that the grouped thread does not use.
6 Anchors from an Apple M6
We set the model's parameters from measurements on a Mac mini with an Apple M6 under macOS 27, taken without root from the per-cluster power estimates the chip's power manager publishes. The six efficiency cores form one cluster (0.97 to 2.94 GHz, 630 to 810 mV); the two super and four performance cores share another (1.44 to 4.79 GHz, 725 to 1105 mV). We switched a light FMA thread on and
Bergach
off every 5 s and took its energy from the change in cluster power over its work in the same windows. From these runs: per FMA on efficiency and performance cores and 270 on super cores; 2.5 and 3.8 FMAs per cycle on efficiency and super cores (we assume 3.2 on performance cores); . The Mac was never idle, so overheads could not be measured; we vary them.
Three observations check the model.
• Riding at a held voltage costs about the voltage ratio squared. Beside two busy threads that held the fast cluster at its top state, the light thread ran on performance cores for 206 pJ per FMA, against 94 pJ on the efficiency cores when it was its own application: 2.19 times, where predicts 2.31.
• Raising costs more. With the busy threads below the top state, the light thread lifted the fast cluster’s voltage by 16 to 66 mV while it ran and paid up to 3.9 times its cost on the efficiency cores, the raise case of Proposition 1.
- macOS moves a thread to the fast cluster when the efficient one runs out of headroom. A light thread in its own application stayed on the efficiency cores up to 4.5 Gops/s and moved by 6 Gops/s; at u = 0.7 the model puts the efficiency cluster's limit at 5.1 Gops/s. The efficiency cluster was awake in all our runs, so by Proposition 2 it was the right place for every light thread it could serve.
The same trade shows on a chip with a single voltage rail. On an AMD Ryzen 9 3900X, a memory-bound thread keeps the idle cores of its core complex awake, at 0.4 to 0.8 W each, which is an overhead in our terms; filling one complex before opening another used 6.7% less rail energy, as Proposition 2 predicts when the overhead is large and the gap in energy per operation small.
7 Related work
Energy-aware schedulers. Linux’s energy-aware scheduler estimates, for each candidate cluster, the energy of placing a task there, including the cost of raising the cluster’s operating point for the tasks already running [12, 13]. Its first energy model, kept in Android, also charged the busy and idle power of whole clusters [1, 18]; mainline Linux dropped idle costs in 2018 [7]. Qualcomm’s scheduler added a static cluster power cost to bias tasks away from idle clusters [16], and an earlier Linux proposal packed small tasks onto busy cores below a fixed load [8]. These systems make the comparison of Proposition 2 numerically or by heuristic; we give its closed form, its bursty version, and the shape it implies.
Apple. Apple’s scheduler notes name the passenger tax and recommend a cluster per thread group and quality-of-service class [3], and its performance controller runs a shared cluster at the highest of its thread groups’ requests [2]. We measure the tax and place the grouping policy against the rule.
Theory. Running a voltage island at the frequency of its most demanding core costs at most a bounded factor over per-core frequencies [17]. Below a critical speed, slowing down wastes energy [9], and dynamic power management decides when to sleep from a break-even time [6]. Heterogeneous cores save energy by matching work to core type [10], and studies of how many types to build find that two or three capture most of the benefit [5, 19]; “non-monotonic” core selection there means core types that cannot be ranked [15], not the non-monotone placement of Theorem 1.
8 Conclusion
Where a light thread should run comes down to three costs and one threshold. It should ride a cluster that is already awake while its demand is below , and otherwise wake the smallest tier that serves it. Because a busy cluster's overhead is already paid while its voltage is high, the best tier is not monotone in demand, and the two common policies fail on opposite sides of the threshold. More tiers make the choice matter more: in our five-tier model, grouping costs 80 to 145% more energy than the rule. A scheduler needs three numbers per cluster to apply it: whether it is awake, its energy per operation where it is held, and its overhead.
Limitations. The model gives each thread its own core and a steady demand, except in Proposition 3. The overheads are not measured on the M6, whose clusters never idled, so the thresholds we quote are for a range of overheads. Our statement about mainline Linux comes from reading its code, not from a measurement. On the M6 the scheduler sometimes ran the light thread on the same cores as the busy ones, which our model does not capture.
Acknowledgments
We used a generative AI assistant (Claude, by Anthropic) to write measurement and analysis scripts, to search the literature, and to draft and edit the text. We reviewed the measurements, the analysis and the text, and we take responsibility for them.
References
[1] Android Open Source Project. [n.d.]. kernel/sched/fair.c (Android common kernel, energy-aware scheduling), branch deprecated/android-4.9-q. https://android.googlesource.com/kernel/common/+/refs/heads/deprecated/android-4.9-q/kernel/sched/fair.c. Commit f9b8314c6464; group_idle_state() and calc_sg_energy(), lines 5757–5872; accessed 18 October 2026.
[2] Jeremy C. Andrus, John G. Dorsey, James M. Magee, Daniel A. Chimene, Cyril de la Cropte de Chanterac, Bryan R. Hinch, Aditya Venkataraman, Andrei Dorofeev, Nigel R. Gamble, Russell A. Blaine, and Constantin Pistol. 2019. Scheduler for AMP architecture with closed loop performance controller. US Patent 10,417,054.
[3] Apple Inc. 2025. Clutch Scheduler: Edge Scheduler Design (XNU doc/scheduler/sched_clutch_edge.md). https://github.com/apple-oss-distributions/xnu/blob/main/doc/scheduler/sched_clutch_edge.md. xnu-12377 source release.
[4] Apple Inc. 2025. XNU source: osfmk/kern/thread_group.c and task_policy.c. https://github.com/apple-oss-distributions/xnu. xnu-12377.1.9.
[5] Omid Azizi, Aqeel Mahesri, Benjamin C. Lee, Sanjay J. Patel, and Mark Horowitz. 2010. Energy-performance tradeoffs in processor architecture and circuit design: a marginal cost analysis. In Proceedings of the 37th Annual International Symposium on Computer Architecture (ISCA). 26–36. doi:10.1145/1815961.1815967
[6] L. Benini, A. Bogliolo, and G. De Micheli. 2000. A survey of design techniques for system-level dynamic power management. IEEE Transactions on Very Large Scale Integration (VLSI) Systems 8, 3 (2000), 299–316. doi:10.1109/92.845896
[7] Dietmar Eggemann. 2018. [RFC PATCH 0/6] Energy Aware Scheduling. Linux kernel mailing list, 20 March 2018; copy at https://lwn.net/Articles/749738/.
[8] Vincent Guittot. 2013. [RFC PATCH v3 0/6] sched: packing small tasks. Linux kernel mailing list, https://lkml.iu.edu/hypermail/linux/kernel/1303.2/03983.html. 22 March 2013.
[9] Ravindra Jejurikar, Cristiano Pereira, and Rajesh Gupta. 2004. Leakage Aware Dynamic Voltage Scaling for Real-Time Embedded Systems. In Proceedings of the 41st Design Automation Conference (DAC). 275–280. doi:10.1145/996566.996650
[10] Rakesh Kumar, Keith I. Farkas, Norman P. Jouppi, Parthasarathy Ranganathan, and Dean M. Tullsen. 2003. Single-ISA heterogeneous multi-core architectures: the potential for processor power reduction. In Proceedings of the 36th Annual IEEE/ACM International Symposium on Microarchitecture (MICRO). 81–92. doi:10.1109/MICRO.2003.1253185
[11] Linux kernel. 2026. kernel/sched/cpufreq_schedutil.c: DVFS headroom. https://github.com/torvalds/linux/blob/v7.3-rc7/kernel/sched/cpufreq_schedutil.c. Tag
Ride, Raise, or Wake
v7.3-rc7, lines 199 and 225–226; include/linux/sched/cpufreq.h lines 32–35; Documentation/admin-guide/pm/cpufreq.rst line 423.
[12] Linux kernel. 2026. kernel/sched/fair.c: compute_energy() and find_energy_efficient_cpu(). https://github.com/torvalds/linux/blob/master/kernel/sched/fair.c. Master at v7.3-rc7 (commit f909e534f5e3), lines 9680–9735; accessed 18 October 2026.
[13] Linux kernel documentation. 2026. Energy Aware Scheduling. https://docs.kernel.org/scheduler/sched-energy.html. accessed 17 October 2026.
[14] Paul Milgrom and Chris Shannon. 1994. Monotone Comparative Statics. Econometrica 62, 1 (1994). doi:10.2307/2951479
[15] Sandeep Navada, Niket K. Choudhary, Salil V. Wadhavkar, and Eric Rotenberg. 2013. A unified view of non-monotonic core selection and application steering in heterogeneous chip multiprocessors. In Proceedings of the 22nd International Conference on Parallel Architectures and Compilation Techniques (PACT). 133–144.
[16] OnePlus. 2016. kernel/sched/fair.c (Qualcomm HMP scheduler, power_cost(), android_kernel_oneplus_msm8996. https://github.com/OnePlusOSS/android_kernel_oneplus_msm8996/blob/oneplus3/6.0.1/kernel/sched/fair.c. Branch oneplus3/6.0.1, commit 93238877f9e8 (29 November 2016), lines 2795–2863.
[17] Santiago Pagani and Jian-Jia Chen. 2014. Energy Efficiency Analysis for the Single Frequency Approximation (SFA) Scheme. ACM Transactions on Embedded Computing Systems 13, 5s (2014), 1–25. doi:10.1145/2660490
[18] Morten Rasmussen. 2014. [RFC PATCH 00/16] sched: Energy cost model for energy-aware scheduling. Linux kernel mailing list, https://lkml.rescloud.iu.edu/1405.2/05307.html. 23 May 2014.
[19] Kenzo Van Craeynest and Lieven Eeckhout. 2013. Understanding fundamental design choices in single-ISA heterogeneous multicore architectures. ACM Transactions on Architecture and Code Optimization 9, 4 (2013), 1–23. doi:10.1145/2400682.2400691