Manuscript Offprint

arXiv:2610.25689

MT-CC: Multi-Group Temperature Scaling for Asymmetric Calibration Behavior in Class-Incremental Learning

Sungjun Yun, Yonghee Choi, Dong-Jun Han

Abstract

As deep neural networks are required to continuously adapt to evolving data, class-incremental learning (CIL) has become an active research area. However, most existing works primarily focus on improving accuracy while overlooking confidence calibration, which measures the trustworthiness of the model's predictions. Although temperature scaling (TS) is effective for static calibration, it has rarely been explored in continual settings where data distributions evolve over time. In this paper, we introduce Multi-Group Temperature Scaling for Continual Calibration (MT-CC), a novel post-hoc calibration framework that addresses the asymmetric calibration behavior in CIL, where the rate of confidence changes does not align with the rate of accuracy degradation across tasks, leading to different levels of miscalibration. Our key contribution is to design multiple temperature parameters through a lightweight grouping network that separates samples by confidence statistics and task-aware signals in CIL. Furthermore, a Groupwise Difference-between-Confidence-and-Accuracy (GDCA) regularization is incorporated to promote intra-group consistency. Experiments demonstrate that MT-CC significantly improves calibration performance while maintaining accuracy, offering a principled framework for reliable continual learning.

1 Introduction

In modern deep learning applications, it has become increasingly important for a model to provide reliable indications of whether its predictions are likely to be correct. In particular, in a well-calibrated model, the predicted confidence should align with the empirical likelihood that the prediction is correct. This allows users to trust the model's outputs when it exhibits high confidence, while rejecting predictions made with low confidence. However, in practice, neural networks are often miscalibrated, producing confidence scores that do not align with their actual accuracy, frequently being overconfident in wrong predictions.

In this context, confidence calibration has attracted increasing attention, aiming to align the model's predicted confidence with the true likelihood of correctness. Various methods have been proposed, including temperature scaling (TS) [12], which performs a post-hoc adjustment of logits to improve calibration without altering the model's predictions. In addition to such post-hoc approaches [7, 12, 16, 22, 37, 45–47, 50], train-time calibration methods have also been explored [8, 14, 23, 27, 28, 36, 41, 49], where the model is explicitly trained to produce well-calibrated confidence scores. Compared to train-time schemes, post-hoc methods such as TS offer a clear advantage, as they can be directly applied to any pre-trained model without sacrificing accuracy.

Code available at https://github.com/DaeZZang/MT-CC

40th Conference on Neural Information Processing Systems (NeurIPS 2026).

Reliability Diagram

Output: Empirical accuracy of predictions falling in each confidence bin (bar height)

Gap: Difference between predicted confidence and empirical accuracy within each bin

ECE: Bin-frequency-weighted mean of [confidence - accuracy].

(1) Overconfident

Confidence > Accuracy

(2) Underconfident

Confidence < Accuracy

Figure

Class-Incremental Learning

Task N Model Inference

(a) Asymmetric Miscalibration in Class Incremental Learning

(b) Limitation of Single Temperature Scaling

(c) MT-CC

Figure 1: The reliability diagram visualizes calibration by comparing empirical accuracy and predicted confidence within each confidence bin, while a lower ECE indicates better calibration. (a) In class-incremental learning, accuracy and confidence evolve at different rates across tasks, producing asymmetric calibration behaviors: the gap between confidence and accuracy varies across tasks due to catastrophic forgetting. (b) As a result, a single global temperature cannot simultaneously calibrate these heterogeneous groups. (c) Our MT-CC routes each sample to a group-specific temperature to capture asymmetric calibration behaviors in class-incremental learning.

Fundamental challenges. However, most prior works on calibration have focused on static scenarios, where the target task and data distribution remain fixed. In many practical settings, however, models are required to learn continuously from a stream of tasks where new classes are introduced over time without revisiting all previous data. In such dynamic environments, maintaining well-calibrated confidence becomes particularly challenging, as the distribution shifts induced by new tasks often lead to varying levels of miscalibration across tasks.

Concretely, as illustrated in Figure 1a, models in class-incremental learning (CIL) [9, 35, 43] exhibit asymmetric calibration behaviors, where accuracy and confidence evolve at different rates across tasks under continual updates (see Figure 2). As a result, a single temperature value T fails to calibrate all classes effectively, since different task groups exhibit distinct confidence characteristics and require differentiated scaling.

Although T-CIL [16] recently proposed a TS strategy tailored to CIL, it still relies on a single temperature value and thus cannot effectively address the asymmetric calibration behaviors of CIL, as illustrated in Figure 1b. Joy et al. [17], Tomani et al. [42] propose sample-dependent temperature scaling, but they are developed under static, fixed-distribution settings and do not explicitly capture the CIL-specific calibration heterogeneity induced by continual task shifts. To the best of our knowledge, these aspects have been largely overlooked in existing calibration research and remain unresolved. Our work seeks to bridge that gap by addressing the following question:

How can we ensure reliable model calibration in continual learning, where asymmetric miscalibration behaviors across tasks pose persistent challenges?

Figure

Figure 2: Confidence-accuracy gap of selected tasks over incremental stages of CIFAR-100. The results reveal asymmetric calibration behaviors in continual learning, where the discrepancy between confidence and accuracy varies across tasks due to catastrophic forgetting. Results for all tasks are provided in Appendix D.

Contributions. In this paper, we propose multi-group temperature scaling for continual calibration (MT-CC), a novel calibration strategy that introduces multiple temperature parameters determined by a grouping network, effectively tackling the asymmetric calibration behavior in continual learning. To this end, we train the grouping network using CIL-specific confidence statistics, including the probability mass assigned to old and new classes and the logit margin, which together capture heterogeneous calibration needs. This enables the grouping network to assign an appropriate temperature to each group, thereby achieving calibration both within each group and across the entire dataset, as shown in Figure 1c. In addition, we propose a Groupwise Difference-between-Confidence-and-Accuracy (GDCA) loss to balance confidence and accuracy within each group, thereby further improving calibration.

Our main contributions are summarized as follows:

• We analyze asymmetric calibration behaviors in class-incremental learning, where different tasks exhibit varying degrees of miscalibration, and exploit these behaviors to design a CIL-aware calibration framework.

• We propose multi-group temperature scaling for continual calibration (MT-CC), a novel calibration framework that introduces multiple temperature parameters determined by a grouping network, enabling input-dependent calibration. The grouping network is conditioned on old/new confidence statistics together with a logit margin signal, allowing it to capture asymmetric calibration behaviors and assign an appropriate temperature to each group.

• We conduct extensive experiments using various benchmark datasets, demonstrating the superiority of MT-CC in class-incremental settings.

References (50)