arXiv:2608.25819Steer the Sampling, Not the Kernel Grid: Geometry-Guided Sampling Operator for Volumetric Segmentation
Sizhe Wang , Himashi Peiris , and Zhaolin Chen
Department of Data Science & AI, Faculty of Information Technology, Monash University, Clayton, VIC, Australia
{sizhe.wang,zhaolin.chen}@monash.edu
Abstract. Accurate 3D segmentation is central to quantitative lesion assessment and anatomy mapping for clinical planning and follow-up. Thin, elongated, and fine anatomical/pathological structures (e.g., vessels) are a particularly stress case: a one-voxel boundary error can disconnect a branch and change clinically relevant topology. In encoder-decoder networks (e.g., U-Net), repeated downsampling and fixed-grid convolution blur/alias fine structures and weaken orientation cues, so early mistakes propagate across scales. We propose a geometry-guided local operator that steers where features are sampled (rather than deforming convolutional kernels) under a single formulation for both feature refinement (stride 1) and resolution reduction (stride > 1). At each voxel, it predicts a local orientation and bounded step sizes, samples symmetrically along these directions, and transforms paired samples into compact geometric/boundary cues with lightweight mixing; a cross-scale consensus aligns encoder and decoder features at skip connections to reduce geometric mismatch. Replacing all stride 1 and stride 2 operators in a 3D U-Net yields consistent improvements on BraTS, MSD Hepatic Vessel, and TDSC-ABUS, with notably better boundary metrics (e.g., BraTS Dice 86.1 → 88.9, HD95 7.1 → 6.2; TDSC-ABUS HD95 39.1 → 27.8) while largely reducing parameters (2.3M → 0.8M). We further demonstrate that the operator plugs into other backbones (e.g. nnU-Net, Swin-UNETR, and MedNeXt) without changing their macro-architectures while providing consistent performance gains. Code available at GeoSample repo.
Keywords: 3D medical image segmentation · geometry-guided sampling · downsampling operator · SO(3) frame field · central differences.
1 Introduction
Accurate volumetric segmentation is a prerequisite for many downstream clinical and scientific workflows, including lesion quantification, preoperative planning, and longitudinal follow-up [21,12]. Encoder–decoder architectures in the U-Net family remain dominant because they combine multi-scale context aggregation with fine localisation through skip connections [23,4]; nnU-Net further
S. Wang et al.
demonstrates strong performance across diverse biomedical tasks using largely standardised backbones and robust training recipes [14]. Despite these successes, thin, elongated, or anisotropic structures remain fragile, and more broadly any task requiring precise boundary localisation can suffer when resolution changes distort local geometry [25]. Such targets often occupy only a few voxels, so small boundary shifts can break continuity and bias quantitative measurements [13]. Therefore, rather than redesigning the backbone, we fundamentally rethink the convolution/pooling primitives that sample, aggregate, and downsample features.
A key issue is that existing stride-based refinement and downsampling indiscriminately aggregate voxel information along fixed grids, suppressing or aliasing high-frequency details and distorting fine structures [2,22], an issue exacerbated by extreme foreground sparsity and limited sampling support. Though anti-aliasing strategies partially address instability under downsampling [29], they remain largely orientation-agnostic and fail to provide a unified approach that preserves boundary geometry and directional cues across scales.
Prior work mitigates cross-scale degradation from several directions. Transformer based and hybrid volumetric segmenters strengthen global context modelling [10,9,17,30,27,20], while other studies target cross-scale calibration and alignment within U-Net pipelines [28]. However, these approaches operate on already-sampled features and do not reconsider the geometric bias introduced by fixed-grid refinement and downsampling.
Adaptive sampling operators move beyond fixed-grid convolutional aggregation by learning sampling offsets, e.g., deformable convolutions [6,31] and volumetric variants [16], as well as sparse large-kernel sampling designs such as OBELISK [11]. However, these methods predict unconstrained offsets per kernel location, lacking structured geometric regularisation and symmetry; neighbouring voxels may yield irregular sampling patterns, and the representation is not orientation-consistent.
Differentiable warping modules and equivariant or steerable architectures incorporate geometric transformations or symmetry constraints [15,7,5,26,8]. However, these existing approaches are either anchored in fixed-grid convolutional backbones or impose global equivariance without explicitly modelling boundary-aligned sampling for both refinement and downsampling. In contrast, we argue sampling directions should be locally structured, rotation-consistent, and symmetrically paired, with bounded step sizes to ensure stability across scales.
We propose GeoSample, a geometry-guided local operator as a unified, plug-in module for volumetric encoder–decoder networks. Rather than deforming kernels, GeoSample predicts a voxel-wise local 3D rotation frame (an element of SO(3)) with adaptive step sizes to steer structured symmetric sampling. The resulting average/difference signals are converted into step-size normalised differential cues that compactly summarise gradient- and curvature-like information. To reduce geometric mismatch between decoder and encoder features, we further employ a rotation-consistent cross-scale consensus mechanism.
Our contributions are threefold: (i) a novel, geometry-guided local operator (GeoSample) that replaces fixed-grid convolution/pooling and unifies stride
1 refinement and stride > 1 downsampling under a single formulation; (ii) a rotation-constrained local frame with adaptive step sizes that enables structured symmetric sampling and extracts compact geometry-aware signals, improving segmentation fidelity for thin or anisotropic targets; and (iii) a rotation-consistent Consensus Field module that aligns geometry at the skip connection, improving robustness across backbones. Fig. 1 provides an overview; we next detail the formulation in Sec. 2.
2.1 Overview and integration
Given an input feature volume , we predict a voxel-wise geometric field (guiding our operator ) and use it to steer symmetric sampling with lightweight mixing. This yields a drop-in local operator that replaces stride 1 refinement blocks and stride > 1 downsampling in 3D encoder-decoder segmenters (Fig. 1).
Stride 1 refinement (replacement of conv blocks). For feature refinement without changing spatial resolution, we generate a geometry-conditioned residual update:
Stride > 1 downsampling (replacement of strided conv/pooling). For spatial reduction, we adopt average pooling as a stable low-pass path and augment it with a geometry-conditioned compensation term:
Consensus Field at skip connection. At each decoder stage, we fuse the geometric field from the upsampled decoder feature with the corresponding encoder skip feature, and apply the stride 1 operator using the fused field before concatenation. This reduces mismatch across the skip connection (Sec. 2.6).
2.2 Geometry field prediction
All operations are applied pointwise at voxel locations; we omit the spatial index for readability. A geometry head predicts a rotation and step-sizes:
Internally, we represent by a unit quaternion (with ); this is used only for rotation fusion in Sec. 2.6. Let be the canonical axes of the image cartesian coordinate system. We take as the first unit directions ( in all experiments, yielding a full local 3D frame) and define sampling offsets
S. Wang et al.

Fig. 1. Overall workflow of the proposed modules. (a) GeoSample: per-voxel geometry field, symmetric sampling, and differential-token mixing. (b) Consensus Field: rotation-consistent fusion of geometry fields from the encoder skip and upsampled decoder features for pre-skip alignment. Shown on a U-Net, GeoSample replaces stride-1 blocks and stride-2 downsampling; Consensus Field is applied at skip connection.
Importantly, are expressed in the same coordinate system as the voxel grid; the frame is used only to steer sampling directions (we do not reparameterise features into a new coordinate system).
2.3 Symmetric sampling and oriented differentials
We view as a continuous field via differentiable trilinear interpolation. For each direction and step size (both predicted at voxel location ), we sample symmetrically:
where is a voxel coordinate. In the continuous domain, the first- and second-order directional differentials along are
and we approximate them by symmetric finite differences with step-size normalisation:
where is a small constant for numerical stability. Here, is an even (context) response, is an odd (directional-change) response, and captures even (2nd-order) curvature-like change. The symmetry makes the odd/even components explicit, while step-size normalisation makes the cues comparable across scales.
2.4 Compact differential tokens and mixing
From we form a gradient-like cue expressed in the image Cartesian axes, and from we form a curvature/Laplacian-like cue :
Sign stability. One key design is symmetric paired sampling, which makes the directional cue sign-invariant by construction: and . This yields stable directional tokens without frame-sign jitter.
We denote the center sample by and collect tokens
We apply a lightweight token-wise gating followed by mixing to obtain an update :
The specific realisation of Gate( ) and Mix( ) is summarised in Sec. 2.7.
2.5 Downsampling with directional-signal preservation
For downsampling, we first compute the stride 1 refined feature Y in (1). Since odd directional signals can undesirably cancel under naive averaging, we deliberately preserve their magnitude by pooling :
and predict a coarse compensation term
2.6 Rotation-consistent Consensus Field and integration
To reduce geometric mismatch between upsampled decoder features and encoder skip features, we fuse two local rotation fields: a current field from the upsampled decoder features with a reference field predicted from encoder skip features, where and . For rotation fusion we use their unit-quaternion representations (with and ).
S. Wang et al.
We compute a consensus gate based on step-size statistics and quaternion similarity:
Rotations are fused by quaternion spherical interpolation and step sizes are blended with the same gate:
The fused field defines the consensus directions and step sizes (via Sec. 2.2) and is used to steer the stride 1 refinement on decoder features at skip connection.
2.7 Implementation notes
We parameterise with a unit quaternion (from a head ) and bound to via a sigmoid. Gate is a grouped conv (one group per token) followed by a Mix conv; stride 1 and downsampling use separate heads. For stability, we stop gradients through in the factors.
3 Experiments
Datasets. We evaluate our method on three public datasets spanning three different modalities: BraTS (MRI) [3,19], MSD HepaticVessel (CT)[1], and TDSC-ABUS (Ultrasound) [18]. HepaticVessel serves as a thin-structure continuity stress test, while BraTS and TDSC-ABUS assess general lesion/tumour segmentation under distinct appearance statistics. We use a fixed-seed 75/10/15 train/val/test split for all methods.
Training and evaluation. All runs use the same training pipeline per dataset with patch-based training and sliding-window inference; patch sizes for Params (model size) / FLOPs (compute cost; number of arithmetic operations) are (BraTS) and (HepaticVessel / TDSC-ABUS). We report mean Dice and boundary metrics (HD95 and ASSD).
Operator-level results. Under a fixed 3D U-Net macro-architecture, we compare the baseline convolution, Deformable Convolution (DCN) v1/v2 [6,31], Dynamic Downsampling (DCD) [28], and the proposed operator by replacing all stride 1 blocks and stride 2 reductions with the respective operator (Table 1). For BraTS, metrics are averaged over enhanced tumour, tumour core and whole tumour; for Hepatic Vessel, we calculated mean metrics on vessel and tumour; for TDSC-ABUS, we report metrics on tumour. Our operator achieves the best mean Dice/HD95/ASSD (71.5/22.8/4.72). It is best on BraTS (88.9/6.2/0.95), attains the best Dice/HD95 on Hepatic Vessel (58.2/34.3) with near-best ASSD (7.43 vs.

Fig. 2. Qualitative comparison on representative cases from BraTS (top), MSD Hepatic Vessel (middle), and TDSC-ABUS (bottom). Shown are input, ground truth, and predictions from the baseline U-Net, DCNv1/v2, Dynamic Downsampling (DCD), and the proposed operator; red boxes mark noticeable segmentation errors reduced by our method.
Table 1. Operator-level comparison across datasets (top: Dice/HD95/ASSD). Bottom: model complexity (Params/FLOPs) under evaluation patch sizes.
| Model | MSD Hepatic Vessel | BraTS | TDSC-ABUS | Mean | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dice↑ | HD95↓ | ASSD↓ | Dice↑ | HD95↓ | ASSD↓ | Dice↑ | HD95↓ | ASSD↓ | Dice↑ | HD95↓ | ASSD↓ | |
| Baseline U-Net | 53.5 | 42.8 | 8.87 | 86.1 | 7.1 | 1.15 | 64.4 | 39.1 | 7.31 | 68.0 | 29.7 | 5.78 |
| Deformable Conv v1 | 57.2 | 37.3 | 7.93 | 88.3 | 6.4 | 1.07 | 67.5 | 33.1 | 5.83 | 71.0 | 25.6 | 4.94 |
| Deformable Conv v2 | 56.7 | 36.3 | 8.21 | 88.3 | 6.5 | 1.33 | 66.3 | 35.4 | 6.06 | 70.4 | 26.1 | 5.20 |
| Dynamic Downsampling | 56.4 | 34.9 | 7.40 | 88.4 | 6.8 | 1.14 | 67.2 | 33.9 | 6.87 | 70.6 | 25.2 | 5.13 |
| Proposed | 58.2 | 34.3 | 7.43 | 88.9 | 6.2 | 0.95 | 67.4 | 27.8 | 5.78 | 71.5 | 22.8 | 4.72 |
| Input size | Baseline U-Net | Deformable Conv v1 | Deformable Conv v2 | Dynamic Downsampling | Proposed | |||||||
| Params (M)↓ | FLOPs (G)↓ | Params (M)↓ | FLOPs (G)↓ | Params (M)↓ | FLOPs (G)↓ | Params (M)↓ | FLOPs (G)↓ | Params (M)↓ | FLOPs (G)↓ | Params (M)↓ | FLOPs (G)↓ | |
| 2.3 | 131.2 | 2.5 | 137.9 | 2.6 | 146.9 | 2.7 | 256.7 | 0.8 | 69.9 | |||
| 2.3 | 194.8 | 2.5 | 203.3 | 2.6 | 209.3 | 2.7 | 384.5 | 0.8 | 108.9 | |||
7.40), and markedly improves boundary metrics on TDSC-ABUS (HD95/ASSD 27.8/5.78) while keeping Dice comparable (67.4), indicating the most stable cross-modality improvements overall.
Computational Complexity. Table 1 (bottom) reports Params and FLOPs in the U-Net setting. Our operator reduces Params from 2.3M to 0.8M and FLOPs from 194.8G to 108.9G. By contrast, DCNv1/v2 slightly increases both, while Dynamic Downsampling raises FLOPs to 256.7G/384.5G. This efficiency comes from using a small number of symmetric samples (e.g., paired directions) and compact token mixing with gating, rather than dense grids or heavy dynamic branches.
Architecture-level plug-in results. On TDSC-ABUS we plug the proposed operator into nnU-Net, Swin-UNETR, and MedNeXt (base version) [14,9,24] (Table 2). For nnU-Net we replace all stride 1 and stride > 1 blocks, whereas for Swin-UNETR and MedNeXt we only replace downsampling to preserve backbone-specific refinement; all variants additionally apply Consensus Field at
S. Wang et al.
Table 2. Architecture-level plug-in validation on TDSC-ABUS dataset.
| Backbone | Variant | Overlap | Boundary | Efficiency | ||||
|---|---|---|---|---|---|---|---|---|
| Dice↑ | Sensitivity↑ | Specificity↑ | HD95↓ | ASSD↓ | Params (M)↓ | FLOPs (G)↓ | ||
| nnU-Net | Baseline | 68.0 | 72.4 | 98.8 | 28.4 | 5.24 | 30.8 | 1250.0 |
| + Proposed | 72.8 | 75.3 | 98.5 | 25.6 | 5.03 | 17.4 | 750.2 | |
| Swin-UNETR | Baseline | 69.1 | 68.0 | 98.6 | 30.2 | 4.97 | 63.5 | 751.5 |
| + Proposed | 70.9 | 74.2 | 98.7 | 27.7 | 4.88 | 64.8 | 802.7 | |
| MedNeXt | Baseline | 66.8 | 69.5 | 99.1 | 29.4 | 5.38 | 2.7 | 50.1 |
| + Proposed | 69.5 | 75.5 | 98.2 | 24.2 | 4.89 | 2.9 | 57.0 | |

Fig. 3. Qualitative plug-in results on TDSC-ABUS (red boxes: improved regions).
skip connection (Sec. 2.6). Across backbones, the plug-in improves overlap and boundary metrics (Dice +1.8--+4.8, Sens. +2.9--+6.2; HD95 -2.5--5.2, ASSD -0.09--0.49), with minor specificity changes (≥98.2%). The largest gain is on nnU-Net (Dice 68.0→72.8) while reducing cost (Params 30.8M→17.4M; FLOPs 1250G→750G); Swin-UNETR and MedNeXt also improve with modest FLOPs changes, consistent with their already-efficient downsampling (patch merging / depthwise separable convolutions). Fig. 3 shows fewer leakage/boundary errors, and Fig. 4 indicates improved volumetry (RVE distributions closer to 0 with fewer outliers and points closer to y = x). Overall, the improved boundaries and volumetry suggest more reliable downstream quantitative assessment across backbones.
Ablation Study. We test the effectiveness of the geometry-aware modules. Under the same 3D U-Net setting using TDSC-ABUS data, removing the differentials (G, L; geometry-aware gradient/curvature cues) drops Dice/HD95/ASSD from 67.4/27.8/5.78 to 54.3/51.0/10.71, and removing the Consensus Field (skip alignment to reduce geometry mismatch) drops to 58.4/48.2/8.52. This confirms that geometric differential terms drive boundary quality, with consensus alignment providing additional cross-scale robustness.
4 Conclusion
We have introduced GeoSample, a geometry-guided operator for volumetric encoder-decoder segmentation that predicts local orientations to steer symmetric sampling and extract geometric signals for refinement and downsampling. Across three public benchmarks and plug-in validation, it consistently improves

Fig. 4. Volumetric agreement on TDSC-ABUS. Left: relative volume error (RVE) distributions for different backbones. Right: predicted vs. ground-truth tumour volumes (log scale) for baseline and +Proposed; dashed line denotes y = x.
segmentation quality, especially boundary metrics, while reducing the number of parameters in the U-Net setting.
Future work will focus on reducing the memory/wall-clock time overhead of interpolation-based sampling and improve early-training stability.
References
-
Antonelli, M., Reinke, A., Bakas, S., Farahani, K., Kopp-Schneider, A., Landman, B.A., Litjens, G., Menze, B., Ronneberger, O., Summers, R.M., et al.: The medical segmentation decathlon. Nature communications 13(1), 4128 (2022)
-
Azulay, A., Weiss, Y.: Why do deep convolutional networks generalize so poorly to small image transformations? Journal of Machine Learning Research 20(184), 1–25 (2019)
-
Baid, U., Ghodasara, S., Mohan, S., Bilello, M., Calabrese, E., Colak, E., Farahani, K., Kalpathy-Cramer, J., Kitamura, F.C., Pati, S., et al.: The rsna-asnr-miccai brats 2021 benchmark on brain tumor segmentation and radiogenomic classification. arXiv preprint arXiv:2107.02314 (2021)
-
Çiçek, Ö., Abdulkadir, A., Lienkamp, S.S., Brox, T., Ronneberger, O.: 3d u-net: learning dense volumetric segmentation from sparse annotation. In: International conference on medical image computing and computer-assisted intervention. pp. 424–432. Springer (2016)
-
Cohen, T., Welling, M.: Group equivariant convolutional networks. In: International conference on machine learning. pp. 2990–2999. PMLR (2016)
-
Dai, J., Qi, H., Xiong, Y., Li, Y., Zhang, G., Hu, H., Wei, Y.: Deformable convolutional networks. In: Proceedings of the IEEE international conference on computer vision. pp. 764–773 (2017)
-
Frangi, A.F., Niessen, W.J., Vincken, K.L., Viergever, M.A.: Multiscale vessel enhancement filtering. In: International conference on medical image computing and computer-assisted intervention. pp. 130–137. Springer (1998)
-
Fuchs, F., Worrall, D., Fischer, V., Welling, M.: Se (3)-transformers: 3d roto-translation equivariant attention networks. Advances in neural information processing systems 33, 1970–1981 (2020)
S. Wang et al.
-
Hatamizadeh, A., Nath, V., Tang, Y., Yang, D., Roth, H.R., Xu, D.: Swin unetr: Swin transformers for semantic segmentation of brain tumors in mri images. In: International MICCAI brainlesion workshop. pp. 272–284. Springer (2021)
-
Hatamizadeh, A., Tang, Y., Nath, V., Yang, D., Myronenko, A., Landman, B., Roth, H.R., Xu, D.: Unetr: Transformers for 3d medical image segmentation. In: Proceedings of the IEEE/CVF winter conference on applications of computer vision. pp. 574–584 (2022)
-
Heinrich, M.P., Oktay, O., Bouteldja, N.: Obelisk-net: Fewer layers to solve 3d multi-organ segmentation with sparse deformable convolutions. Medical image analysis 54, 1–9 (2019)
-
Hesamian, M.H., Jia, W., He, X., Kennedy, P.: Deep learning techniques for medical image segmentation: achievements and challenges. Journal of digital imaging 32(4), 582–596 (2019)
-
Hu, X., Li, F., Samaras, D., Chen, C.: Topology-preserving deep image segmentation. Advances in neural information processing systems 32 (2019)
-
Isensee, F., Jaeger, P.F., Kohl, S.A., Petersen, J., Maier-Hein, K.H.: nnu-net: a self-configuring method for deep learning-based biomedical image segmentation. Nature methods 18(2), 203–211 (2021)
-
Jaderberg, M., Simonyan, K., Zisserman, A., et al.: Spatial transformer networks. Advances in neural information processing systems 28 (2015)
-
Lee, H.H., Liu, Q., Yang, Q., Yu, X., Bao, S., Huo, Y., Landman, B.A.: Deformuxnet: Exploring a 3d foundation backbone for medical image segmentation with depthwise deformable convolution. arXiv preprint arXiv:2310.00199 (2023)
-
Liu, Z., Lin, Y., Cao, Y., Hu, H., Wei, Y., Zhang, Z., Lin, S., Guo, B.: Swin transformer: Hierarchical vision transformer using shifted windows. In: Proceedings of the IEEE/CVF international conference on computer vision. pp. 10012–10022 (2021)
-
Luo, G., Xu, M., Chen, H., Liang, X., Tao, X., Ni, D., Jeong, H., Kim, C., Stock, R., Baumgartner, M., et al.: Tumor detection, segmentation and classification challenge on automated 3d breast ultrasound: The tdsc-abus challenge. arXiv preprint arXiv:2501.15588 (2025)
-
Menze, B.H., Jakab, A., Bauer, S., Kalpathy-Cramer, J., Farahani, K., Kirby, J., Burren, Y., Porz, N., Slotboom, J., Wiest, R., et al.: The multimodal brain tumor image segmentation benchmark (brats). IEEE transactions on medical imaging 34(10), 1993–2024 (2014)
-
Peiris, H., Hayat, M., Chen, Z., Egan, G., Harandi, M.: A robust volumetric transformer for accurate 3d tumor segmentation. In: International conference on medical image computing and computer-assisted intervention. pp. 162–172. Springer (2022)
-
Pham, D.L., Xu, C., Prince, J.L.: Current methods in medical image segmentation. Annual review of biomedical engineering 2(1), 315–337 (2000)
-
Ribeiro, A.H., Schön, T.B.: How convolutional neural networks deal with aliasing. In: ICASSP 2021-2021 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP). pp. 2755–2759. IEEE (2021)
-
Ronneberger, O., Fischer, P., Brox, T.: U-net: Convolutional networks for biomedical image segmentation. In: International Conference on Medical image computing and computer-assisted intervention. pp. 234–241. Springer (2015)
-
Roy, S., Koehler, G., Ulrich, C., Baumgartner, M., Petersen, J., Isensee, F., Jaeger, P.F., Maier-Hein, K.H.: Mednext: transformer-driven scaling of convnets for medical image segmentation. In: International Conference on Medical Image Computing and Computer-Assisted Intervention. pp. 405–415. Springer (2023)
-
Sinclair, B., Pham, W., Vivash, L., Moses, J., Lynch, M., Dorfman, K., Marotta, C., Koh, S., Bunyamin, J., Rowsthorn, E., et al.: Perivascular space identification nnunet for generalised usage (pingu). Medical Image Analysis p. 103903 (2025)
-
Weiler, M., Geiger, M., Welling, M., Boomsma, W., Cohen, T.S.: 3d steerable cnns: Learning rotationally equivariant features in volumetric data. Advances in Neural information processing systems 31 (2018)
-
Xie, Y., Zhang, J., Shen, C., Xia, Y.: Cotr: Efficiently bridging cnn and transformer for 3d medical image segmentation. In: International conference on medical image computing and computer-assisted intervention. pp. 171–180. Springer (2021)
-
Yang, J., Marcus, D.S., Sotiras, A.: Dynamic u-net: Adaptively calibrate features for abdominal multiorgan segmentation. In: Medical Imaging 2025: Computer-Aided Diagnosis. vol. 13407, pp. 326–334. SPIE (2025)
-
Zhang, R.: Making convolutional networks shift-invariant again. In: International conference on machine learning. pp. 7324–7334. PMLR (2019)
-
Zhou, H.Y., Guo, J., Zhang, Y., Han, X., Yu, L., Wang, L., Yu, Y.: nnformer: Volumetric medical image segmentation via a 3d transformer. IEEE transactions on image processing 32, 4036–4045 (2023)
-
Zhu, X., Hu, H., Lin, S., Dai, J.: Deformable convnets v2: More deformable, better results. In: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. pp. 9308–9316 (2019)