arXiv:2610.23325eess.IVOct 2026

Manuscript Offprint

arXiv:2610.23325

TransNSNet: A Transformer-Enhanced Multi-Scale Adversarial Framework for CT-to-PET Image Synthesis

Shaojun Li, Xiaoyu Deng, Ikuo Keshi

Abstract

This study investigates CT-to-PET image synthesis using TransNSNet, a Transformer-enhanced multi-scale adversarial framework. A paired CT-PET dataset was curated from the public non-small cell lung cancer (NSCLC) Radiogenomics collection through patient screening, slice-level matching, preprocessing, and patient-level train-test separation. The proposed framework generates PET-like predictions at multiple spatial scales and applies coarse-to-fine reconstruction supervision, while TransPatchGAN introduces contextual feature interaction into adversarial evaluation. A progressive ablation study compares Pix2Pix, NSNet-Base, NSNet-D, and TransNSNet. Image-level performance was summarized over a fixed convergence window (epochs 80–101) from one training run per model. TransNSNet achieved the best mean value in nine of ten metrics, whereas NSNet-Base achieved the highest visual saliency-induced index. For fixed-fraction high-intensity regions, NSNet-D was marginally higher in slice-level recall and balanced accuracy, but the equal-weight patient-level values were nearly identical and the highest Dice values shifted to TransNSNet. These differences were small relative to between-patient variability. In the separate adaptive patient-level analysis (n = 10), no pairwise model difference remained statistically significant after Holm correction. TransNSNet also had a substantially smaller parameter footprint than the original next-scale models. These findings indicate promising image-quality trends, but they do not establish statistical superiority or clinical validity; synthesized PET-like images should not be interpreted as substitutes for clinically acquired PET.

Keywords: CT-to-PET image synthesis, medical image synthesis, multi-scale generation, Transformer, TransNSNet, TransPatchGAN.

Preprint. Submitted for publication.

1. Introduction

Medical imaging plays a fundamental role in modern disease diagnosis, treatment planning, and longitudinal monitoring. Different imaging modalities provide complementary information about human anatomy and physiology. Computed tomography (CT) provides high-resolution anatomical and structural information by measuring tissue-dependent X-ray attenuation, making it suitable for depicting organs, bones, and tissue-density variations. Positron emission tomography (PET), in contrast, visualizes metabolic and functional activity through the spatial distribution of radiotracer uptake. In oncology, the combination of anatomical CT information and metabolic PET information is particularly valuable for tumor localization, staging, treatment response assessment, and follow-up analysis.

Despite its clinical value, PET imaging remains less accessible than CT in many practical scenarios. PET examinations require radiotracer administration, involve additional radiation exposure, depend on specialized imaging systems and radiochemistry infrastructure, and are generally more expensive than CT. As a result, CT examinations are more widely available, whereas paired PET information may be unavailable for many patients or difficult to obtain repeatedly. These limitations have motivated increasing interest in CT-to-PET image synthesis, which aims to estimate PET-like images from CT images and thereby provide auxiliary PET-like intensity representations for research and methodological analysis. It should be emphasized that synthesized PET-like images are not intended to replace clinically acquired PET scans. Instead, they may serve as complementary computational outputs when real PET acquisition is unavailable, limited, or impractical.

CT-to-PET synthesis is an intrinsically challenging cross-modality image translation problem. CT and PET are generated by fundamentally different physical mechanisms. CT mainly reflects anatomical density and attenuation properties, whereas PET reflects radiotracer uptake associated with biological and metabolic activity. Therefore, PET uptake patterns cannot be fully determined from

∗^{*}Corresponding author.

Email address: keshi@fukui-ut.ac.jp (Ikuo Keshi)

CT anatomy alone. A reliable CT-to-PET synthesis model must learn statistical correspondences between the two modalities while avoiding physiologically implausible uptake patterns. This requirement is especially important in medical imaging, because synthetic images that appear visually plausible but contain incorrect metabolic information may mislead subsequent interpretation or downstream analysis.

Deep learning has substantially advanced medical image synthesis and cross-modality translation. Encoder-decoder networks and U-Net-based architectures can learn direct image-to-image mappings under paired supervision. However, regression-dominated training often produces overly smooth predictions and may suppress subtle local structures. Generative adversarial networks (GANs), especially conditional image-to-image translation frameworks such as Pix2Pix, introduce a discriminator to encourage generated images to better match the target-domain distribution. Nevertheless, conventional single-output translation frameworks still face difficulties in CT-to-PET synthesis. A single full-resolution supervision signal may be insufficient to guide the model to learn both global metabolic layout and local uptake details. In addition, the discriminator design affects what type of realism is emphasized during adversarial training. A purely local discriminator can provide regional feedback but may lack global contextual awareness, while a global discriminator may not sufficiently penalize local uptake inconsistencies.

Another practical challenge is the construction of paired CT-PET datasets. Supervised CT-to-PET translation requires well-matched source and target images. However, paired CT-PET data are not always directly available in a slice-level format suitable for training image translation models. In this study, we therefore construct a paired CT-PET translation dataset by screening, matching, and preprocessing CT and PET images from the public non-small cell lung cancer (NSCLC) Radiogenomics dataset Bakr et al. (2017, 2018). Only cases with matched CT and PET slice correspondence are retained, enabling supervised evaluation of CT-to-PET synthesis models.

To address the above challenges, this study proposes TransNSNet, a Transformer-enhanced next-scale adversarial framework for CT-to-PET image synthesis. Pix2Pix is used as a representative conditional GAN baseline. NSNet-Base is constructed by replacing the Pix2Pix U-Net generator with a next-scale generator that produces PET predictions at multiple spatial scales and provides coarse-to-fine supervision during training. NSNet-D further replaces the PatchGAN-style discriminator with a Transformer-enhanced TransPatchGAN discriminator to isolate the contribution of discriminator-side contextual modeling. Finally, TransNSNet combines a Transformer-enhanced next-scale generator with the TransPatchGAN discriminator, enabling both generator-side global feature interaction and discriminator-side contextual adversarial feedback.

The main contributions of this study are summarized as follows:

  1. We curate a paired CT-PET image translation dataset from the public NSCLC Radiogenomics collection. The contribution includes patient screening, slice-level CT-PET matching, image preprocessing, and patient-level train-test separation, resulting in 147 retained patients and 41,864 paired slices for supervised synthesis experiments.

  2. We develop and analyze a Transformer-enhanced next-scale generator for CT-to-PET synthesis. The generator predicts PET-like images at six spatial resolutions and is optimized with coarse-to-fine reconstruction supervision; its contribution is evaluated separately for structural, perceptual, and error-based metrics rather than assumed to be uniform.

  3. We introduce a Transformer Block into the discriminator to construct TransPatchGAN. This design extends conventional patch-level adversarial evaluation with contextual feature interaction and enables a component-wise analysis of local and broader uptake consistency.

  4. We conduct a comprehensive evaluation including progressive ablation, fixed-fraction high-intensity-region and adaptive lesion-like uptake analyses, patient-level statistical testing, and model parameter comparison. TransNSNet obtains the best convergence-window mean in nine of ten image-quality metrics with a substantially smaller parameter footprint than the original next-scale models, while the regional results reveal model- and metric-dependent trade-offs.

The remainder of this paper is organized as follows. Section 2 reviews related work on cross-modality medical image synthesis, GAN-based medical image translation, multi-scale generation, Transformer-based image modeling, and evaluation of synthetic medical images. Section 3 introduces the proposed framework and its ablation variants. Section 4 describes the dataset construction, preprocessing procedure, experimental settings, ablation design, and evaluation metrics. Section 5 presents quantitative and qualitative results. Section 6 discusses the technical advantages, limitations, and use boundaries of the proposed method. Section 7 concludes the paper and outlines future research directions.

References (35)