arXiv:2610.23360cs.CVOct 2026

Manuscript Offprint

arXiv:2610.23360

UniPolar: Joint Image and Polarimetric Restoration under Compound Degradations via Physical Consistency Learning

Yang Jin, Guangyu Guo, Linghao Shen, Binglu Wang

Yang Jin, Guangyu Guo, Linghao Shen, Binglu Wang†

Abstract—Polarimetric image restoration aims to recover polarization-angle images and reliable polarimetric quantities from degraded observations. Beyond visual fidelity, it also requires preserving the physical relationships underlying reliable polarimetric estimation. However, existing methods typically address either device- or environment-induced degradations in isolation, limiting their applicability to color-polarization filter array (CPFA) imaging, where both often coexist. Such compound degradations jointly perturb image intensities and cross-angle polarization differences. Consequently, improved image fidelity alone does not necessarily ensure accurate Stokes, DoLP, and AoLP recovery. To address this challenge, we propose UniPolar, a coupled Image–Stokes framework for joint image–polarimetric restoration from compound-degraded CPFA observations. Specifically, UniPolar employs two complementary streams to reconstruct four polarization-angle images and directly predict Stokes difference components. To coordinate these streams, Degradation-Conditioned Cross-Domain Interaction combines Dual-Domain Frequency Interaction for frequency-selective evidence exchange with Degradation-Conditioned Modulation for condition-adaptive feature correction. Furthermore, at the output level, Image–Stokes Physical Consistency Learning aligns image-derived and directly predicted Stokes components while regularizing angular fidelity and the physical feasibility of DoLP. On the compound-degradation benchmark, UniPolar achieves average image and DoLP PSNRs of 31.522 dB and 24.097 dB, respectively, with an average AoLP error of 16.833°. These results underscore the importance of jointly considering visual fidelity and polarimetric reliability, offering a physically grounded perspective on learning-based restoration under compound degradations.

Index Terms—Joint image and polarimetric restoration, color-polarization filter array, compound degradation, Stokes parameters, physical consistency.

I. INTRODUCTION

Polarimetric imaging captures physical cues beyond RGB intensity and has been widely used in reflection removal, reflective-surface reconstruction, and shape recovery [1]–[5]. In color-polarization filter array (CPFA) imaging systems, polarized images with different polarizer angles are spatially multiplexed on a single sensor, from which Stokes parameters, the degree of linear polarization (DoLP), and the angle of linear polarization (AoLP) are estimated. Therefore, polarimetric image restoration is not merely a multi-channel image reconstruction problem: it must recover visually faithful polarized images while preserving the physical relationships required for reliable AoLP and DoLP estimation.

Yang Jin and Binglu Wang are with School of Astronautics, Northwestern Polytechnical University, Xi'an 710072, China (e-mail: {jin91999, wbl921129}@gmail.com)

Guangyu Guo is with School of Computer Science and Technology, Zhejiang University, Hangzhou 310058, China (e-mail: gyguo95@gmail.com)

Linghao Shen is with School of Marine Science and Technology, Tianjin University, Tianjin, 300072, China (e-mail: shenlinghao@tju.edu.cn)

†Corresponding author: Binglu Wang

Figure

Environment-based degradation

(a) Compound degradations

Figure

Degradations

(b) UniPolar: joint image-polarimetric restoration

Fig. 1. (a) Coupled device- and environment-induced degradations in CPFA observations impair both image and polarimetric restoration. (b) UniPolar jointly recovers polarization-angle images and polarimetric quantities, promoting Image–Stokes consistency from cross-domain representations to physically constrained outputs.

In CPFA polarimetric imaging, observations are usually affected by compound device-based and environment-based degradations, as illustrated in Fig. 1(a). On the device side, the spatial multiplexing of different polarizer angles leads to directional undersampling, producing a mosaicked observation, while sensor acquisition introduces resolution loss and noise. On the environment side, adverse imaging conditions such as low illumination and haze reduce contrast, degrade polarization measurements, and lower the effective signal-to-noise ratio. These degradations often occur jointly, producing sparse and noisy CPFA observations under challenging illumination or scattering conditions. They not only reduce visual quality but also disrupt the Stokes-consistent relationships among polarizer-angle measurements, with errors propagating to Stokes parameters and derived polarization attributes.

Existing task-specific polarimetric image restoration methods have advanced individual tasks, including demosaicking, denoising, low-light enhancement, deblurring, super-resolution, and dehazing [6]–[17]. Most, however, primarily address device-induced degradations or isolated environmental conditions, without sufficiently accounting for their compounded effects. Recent joint and shared-architecture methods broaden task coverage through joint demosaicking, denoising, super-resolution, or Image–Stokes modeling [14], [16], [18], [19], but they are generally optimized for predefined degradation pipelines or require degradation-specific training. General multi-degradation restoration methods instead handle multiple degradation types within one model [20]–[32]. Nevertheless, these methods mainly target conventional RGB images without explicitly modeling cross-angle polarization differences or the physical relationships required for reliable Stokes estimation. These limitations highlight the challenge of jointly restoring visual fidelity and reliable polarimetric information from compound-degraded CPFA observations.

To bridge this gap, we formulate compound-degraded CPFA restoration as a physically coupled image–polarimetric restoration problem that requires simultaneously recovering visually faithful polarization-angle images and reliable polarimetric quantities from the same degraded observation. To this end, we propose UniPolar, a coupled Image–Stokes framework illustrated in Fig. 1(b). UniPolar preserves image and polarimetric representations in separate streams and couples them through Degradation-Conditioned Cross-Domain Interaction, where Dual-Domain Frequency Interaction (DDFI) exchanges frequency-selective evidence and Degradation-Conditioned Modulation (DCM) applies condition-adaptive corrections. At the output level, Image–Stokes Physical Consistency Learning (PCL) reconciles image-derived and directly predicted polarimetric quantities through component, angular, and feasibility constraints. This design provides a physically informed approach to compound-degraded CPFA restoration, emphasizing that polarimetric reliability should be explicitly considered alongside image fidelity.

Our main contributions are summarized as follows:

• We formulate compound-degraded CPFA restoration as a physically coupled problem, aiming to jointly recover visually faithful polarization-angle images and reliable polarimetric quantities.

• We propose UniPolar, a coupled Image–Stokes framework with Degradation-Conditioned Cross-Domain Interaction, combining DDFI and DCM for frequency-selective evidence exchange and condition-adaptive feature correction.

• We introduce Image–Stokes Physical Consistency Learning to align image-derived and directly predicted polarimetric quantities through component, angular, and feasibility constraints, thereby improving physical consistency and restoration accuracy.

References (60)