arXiv:2610.19218cs.CVOct 2026

Manuscript Offprint

arXiv:2610.19218

A Gradient-Regularized Deep Learning Method for Restoring Image in Myopic Vision

Kebin Contreras, Luis Toscano-Palomino, Rafael Torres, Jorge Bacca

1st1^{st} Kebin Contreras

Physics School

Univ. Industrial of Santander

Bucaramanga, Colombia

2nd2^{nd} Luis Toscano-Palomino

Dept. of Computer Science

Univ. Industrial of Santander

Bucaramanga, Colombia

3rd3^{rd} Rafael Torres

Physics School

Univ. Industrial of Santander

Bucaramanga, Colombia

4th4^{th} Jorge Bacca

Dept. of Computer Science

Univ. Industrial of Santander

Bucaramanga, Colombia

Abstract—Myopic vision degrades the quality of human vision due to spherical eye defocus aberrations that impair the perception of fine spatial details. To address this limitation, this work proposes a deep learning-based approach to computationally design transformed images that allow individuals with myopia in fixed distance to perceive scenes with enhanced clarity. The method trains a neural network to counteract defocus aberrations modeled using the second-order Zernike polynomial Z20Z_2^0. The approach employs a U-Net architecture trained with a loss function combining reconstruction error minimization with spatial difference structural preservation through ℓ1\ell_1 regularization. Training is carried out exclusively on the KITTI dataset, while testing is performed on DIV2K and ImageNet datasets, demonstrating generalization across diverse image distributions. Under myopic conditions modeled by Z20Z_2^0, baseline performance shows visual degradation with PSNR values ranging from 19.47 to 27.42 dB across datasets and severity levels. The proposed gradient-regularized method achieves consistent improvements, delivering PSNR gains ranging from 1.48 to 7.34 dB and significantly lower perceptual compared to classical baselines.

Index Terms—Myopia correction, Zernike polynomials, gradient regularization, image restoration.

I. INTRODUCTION

Visual quality in human vision is essential for everyday tasks, as even minor eye degradations can affect perception and decision-making [1]. Among refractive errors, myopia (nearsightedness) represents one of the most prevalent visual impairments worldwide, affecting more than 2.6 billion people and projected to affect nearly half of the world population by 2050 [2]. Myopic aberrations degrade the quality of visual input by causing blurring of distant objects, distorting spatial information, and reducing the ability to resolve fine details [3]. These imperfections impact daily activities that require distance vision, such as driving, sports, and classroom learning [3]–[5].

To quantitatively model myopic aberrations in the human eye, Zernike polynomials serve as mathematical tools to represent the aberrated wavefront emerging at the pupil plane after light passes through the eye's optics [6]. These polynomials decompose the wavefront distortions into a series of orthogonal basis functions on a unit disk, providing a compact description of ocular imperfections [4]. Specifically, the second-order Zernike polynomial Z20Z_{2}^{0} represents defocus aberrations corresponding to spherical refractive errors that cause the uniform blurring observed in myopia [7].

Historically, myopia correction has been based on physical optical elements such as concave lenses with specific diopter strengths tailored to individual prescriptions [8]. However, traditional corrective approaches face several limitations including physical constraints, comfort issues, and challenges in dynamic correction for varying visual demands [3]. Moreover, the social and psychological implications of visual impairment can further limit the acceptance of conventional treatments [3]. Computational strategies have emerged as promising alternatives, proposing digital modification of visual content to compensate for optical aberrations. Similarly, [9] proposed a light field-based eyeglasses-free display; however, their approach exhibits limited generalization since the hardware-dependent calibration fails under changing user head positions, off-axis viewing angles, or varying screen distances, and it does not rely on a formal optical aberration model grounded in wavefront theory.

This work addresses these limitations by proposing a gradient-regularized computational strategy specifically designed for myopia pre-compensation. As illustrated in Fig. 1, our approach models the eye’s degradation using a physics-based point spread function (PSF) derived from the second-order Zernike polynomial Z20Z_{2}^{0} to accurately simulate spherical defocus [10]. Unlike conventional image restoration designed for digital sensors, we focus on scenarios with fixed viewing distances, such as digital displays, where a spatially invariant model provides an appropriate first-order approximation. Our method pre-transforms content ( fθf_{\theta}) so that it appears clear to a myopic human observer after passing through their aberrated optics (h). By centering the study on this specific refractive error, we establish a robust baseline for computational correction before extending to more complex aberrations such as astigmatism.

The proposed approach trains a U-Net architecture [11] on the KITTI dataset [12] using a gradient-regularized loss that balances pixel fidelity with structural preservation through ℓ1\ell_{1}-norm constraints on spatial gradients [13]. As shown in the final stages of Fig. 1, the resulting model demonstrates strong generalization on the DIV2K [14] and ImageNet [15] datasets, outperforming classical Wiener filtering and non-regularized baselines in both signal fidelity (PSNR/SSIM) and perceptual metrics (LPIPS).

Figure

I: Original image (scene / optotype)

h: Eye degradation operator (myopia Z02Z_{0}^{2})

fθf_{\theta}: Compensation model parameterized by θ\theta

h∗fθh * f_{\theta}: Result after the visual system

Fig. 1. Proposed computational pre-compensation pipeline. The process involves modeling the myopic visual system using Zernike polynomials ( Z20Z_2^0), applying a deep learning-based compensation model ( fθf_\theta), and evaluating the restored result ( h∗fθh * f_\theta) through signal and perceptual metrics.