arXiv:2610.19893cs.SDOct 2026

Manuscript Offprint

arXiv:2610.19893

Few-Shot Adaptation for Anomalous Sound Detection at Low False-Positive Rate

Simone Lugani, Christof Pichler, Hannes Wegleiter, Christoph Feilmayr, Rodolfo Zunino, Edoardo Ragusa

Simone Lugani*, Christof Pichler†, Hannes Wegleiter†, Christoph Feilmayr‡, Rodolfo Zunino*, Edoardo Ragusa*

*DITEN, University of Genoa, Genoa, Italy; contact: simone.lugani@edu.unige.it

†Christian Doppler Laboratory for Measurement Systems for Harsh Operating Conditions, EMS, TU Graz, Graz, Austria

‡ voestalpine Stahl GmbH, Linz, Austria

Abstract—Reliable fault detection is crucial for industrial machinery in large-scale facilities, where unexpected failures can cause costly downtime and production interruptions. Although acoustic monitoring provides a scalable solution for machine condition monitoring, its deployment is often constrained by high false-positive rates. We propose a two-step approach to automatic anomalous sound detection: first, when only normal operating audio samples are available, a regularized unsupervised model is deployed; then, after the first machine fault, a few-shot adaptation strategy exploits the anomalous samples acquired during the fault to improve the system. This adaptation increases the area under the precision-recall curve (AUPR) from 23.0 to 64.0 and improves detection in the low false-positive-rate region, with the partial area under the receiver operating characteristic curve (pAUROC) increasing from 39.6 to 72.8. We also show that covariance regularization improves both prediction accuracy and training stability in the unsupervised model. These results provide a practical strategy for acoustic anomaly detection systems, enabling improved accuracy and reduced false alarms.

Keywords—Anomalous Sound Detection, Fault detection, Predictive Maintenance, Few-Shot Learning

I. INTRODUCTION

Reliable operation of industrial machinery is essential in continuous-process industries, where unexpected failures can cause costly downtime and production interruptions [1]. This is vital in pig iron production, where the blast furnace stock house prepares raw materials before charging, and large vibrating screens make early fault detection essential for reliable operation. While vibration-based monitoring is well established, its use in large-scale facilities is often limited by the required sensor effort and installation cost [2]. Acoustic condition monitoring uses microphones to capture machine-related sound emissions [3]. In stock house environments, however, multiple concurrently operating screens, time-varying background noise, and additional disturbances can mask weak fault-related signatures, making reliable detection difficult [4].

Instead of requiring large labelled fault datasets, unsupervised anomalous sound detection (ASD) systems learn normal machine behaviour and identify deviations as anomalies [4]. In recent years, this field has advanced strongly, in particular through the DCASE challenge series, where a wide range of data-driven methods for machine condition monitoring has been developed [5]–[10]. Recent DCASE tasks have also moved towards first-shot and domain-generalisation settings, which are highly relevant for practical applications [11]–[15].

Figure

Fig. 1. Block diagram of the ASD framework: the log-mel spectrogram is compressed by the CVAE; then, a GMM is used to compute the anomaly score based on vector similarity with the learned normal representation.

However, a gap remains between current ASD research and the requirements of real industrial applications. In large-scale facilities, the system must operate at very low false-positive rates (FPR), since even a small number of false alarms can limit the usability and acceptance of monitoring systems. At the same time, real-world acoustic conditions are highly complex due to multiple simultaneously operating machines, changing operating states, and additional disturbing sound sources [4]. While ASD has already been applied to such harsh acoustic environments [16], [17], the resulting FPRs often remain a limiting factor for reliable deployment. In addition, a small number of fault samples is often available after the first observed failure, creating an opportunity to improve the separation between normal and faulty conditions and, in particular, to reduce false alarms. This setting can be viewed as a few-shot adaptation scenario, where only limited anomalous data are available for model adaptation.

We propose a two-stage ASD framework for industrial applications that enables targeted refinement of an unsupervised model using a small number of fault samples. First, a convolutional variational autoencoder (CVAE) extracts the features, and a Gaussian mixture model (GMM) models the normal operating condition using only normal data. Later, after the first observed fault, the CVAE is fine-tuned with a few anomalous samples from a single machine fault, while the GMM is kept fixed as a reference for the normal latent distribution. This refinement improves the separation between normal and faulty conditions, with focus on the low-FPR operating region, after the first machine fault. In addition, we investigate covariance regularization in the GMM, which improves robustness in the unsupervised setting. The evaluation is conducted on real-world acoustic data from an operating industrial blast furnace stock house, demonstrating relevance under realistic deployment conditions. The proposal outper-

© 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.

Published in IEEE COINS 2026.

DOI: 10.1109/COINS69995.2026.11715629.

forms the baselines in terms of overall AUPR and detection capabilities under stringent false-alarm requirements.