Abstract

Background: Accurate partial volume (PV) estimation, i.e., subvoxel tissue fractions, from Magnetic Resonance Fingerprinting (MRF) remains challenging, as conventional methods such as dictionary matching or segmentation tools like FSL FAST rely on multi-stage iterative pipelines, where inaccuracies in early steps (e.g., parametric map estimation) can propagate and compromise the final tissue fraction maps.

Purpose: This study introduces DeepPV-MRF, a deep learning framework designed to directly map raw MRF signals to voxel-wise tissue fraction maps. The goal is to provide a more accurate and efficient alternative to existing iterative and dictionary-based PV estimation methods.

Methods: DeepPV-MRF employs a cascaded spatial-temporal neural network trained on subject-derived simulations generated through Bloch modeling with radial k-space undersampling. The integrates voxel-wise temporal encoding with spatial U-Net refinement to estimate CSF, GM, and WM fractions without intermediate T1/T2 maps. Performance was evaluated against PV dictionary matching (PV-DM), and PV pseudoinverse (PV-Pinv), using both simulated and in vivo data.

Results: The proposed method substantially outperformed competing methods across all acquisition settings. In single-shot simulations, the CSF/WM/GM MAEs were 0.0418/0.0744/0.0757, compared with 0.1281/0.2443/0.2958 for PV-DM and 0.2021/0.2793/0.2630 for PV-Pinv; the corresponding SSIM values were 0.960/0.916/0.922. The in vivo experiments qualitatively showed sharper anatomical boundaries and smoother tissue transitions, while the cross-shot analysis supported improved consistency across volunteers.

Conclusions: In conclusion, DeepPV-MRF offers a robust, accurate, and efficient framework for direct partial volume estimation in MRF. By eliminating reliance on intermediate reconstructions and improving performance particularly in low-shot scenarios, the method addresses critical weaknesses of existing approaches. These results support the practical feasibility of DeepPV-MRF and motivate further validation before clinical deployment.

Keywords: Magnetic Resonance Fingerprinting, Partial Volume Estimation, Deep Learning, Tissue Quantification

1 Introduction

Quantitative MRI (qMRI) is a non-invasive imaging framework that enables numerical characterization of tissue microstructure 1^{1}. Broadly, qMRI applications fall into two major categories: parametric mapping and tissue composition estimation. The former focuses on extracting intrinsic tissue properties such as longitudinal relaxation time ( T1T_{1}) and transverse relaxation time ( T2T_{2}), which serve as biophysical biomarkers for disease diagnosis. The latter aims to estimate metrics such as volume or thickness of tissue such as gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) in the brain.

While parametric maps provide valuable insights into tissue biophysics, they do not directly account for tissue mixing within a voxel 2^{2}. Conventionally, tissue composition estimation assumes that each voxel contains a single homogeneous tissue type 3^{3}. However, this assumption fails in regions where voxels span across anatomical boundaries. This limitation becomes particularly important in clinical brain imaging, where partial volume (PV) effects are prevalent due to the limited spatial resolution of MRF 4,5,6^{4,5,6}. PV effects can substantially impair the accuracy of tissue quantification 2^{2}, lesion size estimations 7^{7}, and brain atrophy assessment 8^{8}.

To characterize sub-voxel tissue heterogeneity, voxel-wise tissue fraction estimation—i.e., quantifying the relative proportions of GM, WM, and CSF in each voxel—is essential. Traditional approaches to PV estimation typically rely on regularized statistical models, such as Gaussian mixture models (GMMs) combined with expectation-maximization (EM) 9,10,11,12^{9,10,11,12}, often applied to multi-contrast structural MRI. These methods assume that each tissue class exhibits a well-defined intensity distribution across modalities and that voxel intensities result from a linear mixture of pure tissue responses. While effective in structural imaging, these assumptions do not hold in quantitative techniques like Magnetic Resonance Fingerprinting (MRF), where voxel signals represent non-linear temporal evolutions rather than static intensities.

MRF 13^{13} signal representation captures multi-parametric information in a single scan, making it an attractive candidate for direct tissue composition estimation. One early attempt to incorporate PV modeling into MRF is the partial volume dictionary matching (PV-DM) method 3,13^{3,13}, which estimates tissue fractions through dictionary matching. While promising, this method inherits several limitations from the underlying dictionary-based paradigm. First, dictionary-based MRF reconstruction becomes computationally demanding as the size and resolution of the dictionary increase, especially for applications involving partial volume modeling where dense sampling of tissue parameter space may be necessary 13,14,15,16^{13,14,15,16}. Second, PV-DM relies on a strong “pure-tissue” assumption, requiring manually defined reference clusters with fixed relaxation times for GM, WM, and CSF. This introduces subjectivity and operational complexity, making it difficult to deploy in automated or clinical pipelines. These challenges motivate the need for more flexible, data-driven approaches to sub-voxel tissue fraction estimation in the MRF context.

Recent studies have explored deep learning as an alternative to dictionary-based MRF reconstruction, demonstrating improved efficiency and scalability 17,18,19,20,21,22,23,24^{17,18,19,20,21,22,23,24}. These methods typically train convolutional or transformer-based models to map MRF time-series signals to voxel-wise tissue parameters such as T1T_{1} and T2T_{2}. For example, DRONE 17^{17} first introduced a fully connected neural network to directly regress quantitative maps from signal evolutions. SCQ 18^{18} extended this approach using convolutional architectures. More recent transformer-based models 21^{21} have shown further improvements in spatial consistency and generalization. However, most existing models are designed with a single-compartment model and do not explicitly estimate tissue fractions in partial volume voxels. While these models have demonstrated strong performance in parametric map reconstruction, they are not designed to resolve sub-voxel tissue mixing. As a result, partial volume effects remain unaddressed in most existing MRF-based deep learning pipelines, limiting their utility in tasks that require accurate tissue composition analysis.

This limitation motivates the need for models capable of explicitly estimating sub-voxel tissue fractions from MRF signals.

To this end, we present DeepPV-MRF, an end-to-end deep learning framework for directly estimating voxel-wise tissue fraction maps from aliased MRF signal evolutions. The goal is to estimate the relative fractions of CSF, GM, and WM within each voxel, without relying on intermediate T1T_{1} or T2T_{2} maps. Extending the methodology proposed in MRF-Mixer 24^{24}, we construct a fully simulated training dataset in which each voxel is assigned reference tissue fractions derived from high-resolution anatomical segmentations and corresponding pure-tissue relaxometry estimated from in vivo acquisitions. Unlike conventional partial volume estimation techniques such as partial volume pseudoinverse (PV-Pinv) and PV-DM 3^{3}, which depend on predefined pure tissue fingerprints and manually designed subdictionaries, our method learns the mapping from MRF signals to tissue fractions directly from data, removing the need for dictionary construction, signal matching, or parameter discretization.

References (14)

  • A review, World journal of radiology 6, 855
  • a review of papers published since its inception, Alzheimer’s & Dementia 9, e111–e194
  • technical aspects, Journal of Magnetic Resonance Imaging: An Official Journal of the International Society for Magnetic Resonance in Medicine 9, 519–530
  • Thiran, Comparison and validation of tissue modelization and statistical classification methods in T1-weighted MR brain images, IEEE transactions on medical imaging 24, 1548–1565
  • A Model-Based Deep Learning Approach Leveraging Learned Sparsity and Physics Priors, IEEE Transactions on Computational Imaging
  • A Simulation-Based Deep Learning Framework for Accelerated and Accurate Magnetic Resonance Fingerprinting Reconstruction, Information 16, 218
  • GPU-accelerated magnetic resonance fingerprinting dictionary generation and matching using extended phase graphs, Magnetic resonance imaging 66, 248–256
  • A Self-Supervised Deep Learning MRF Framework, Proc
  • multi-echo MP2RAGE for simultaneous T1-weighted imaging, T1 mapping, mapping, SWI, and QSM from a single acquisition, Magnetic resonance in medicine 83, 1178–1191
  • An Official Journal of the International Society for Magnetic Resonance in Medicine 9, 531–538
  • An Official Journal of the International Society for Magnetic Resonance in Medicine 54, 507–512
  • 25 years of image analysis, Nature methods 9, 671–675
  • An Overview of Multi-Task Learning in Deep Neural Networks
  • >Single-shot</td><td>CSF</td><td>$19.25\pm3.62$</td><td>$43.35\pm7.50$</td></tr><tr><td>WM</td><td>$38.98\pm7.53$</td><td>$83.00\pm13.41$</td></tr><tr><td>GM</td><td>$55.34\pm10.12$</td><td>$95.24\pm15.34$</td></tr><tr><td rowspan=