arXiv:2610.20289cs.CEOct 2026

Manuscript Offprint

arXiv:2610.20289

Generating Accurate Microstructures of Anisotropic Magnetorheological Elastomers

Heinrich T. Roth, Lukas Jabs, Matti Schneider, Konstantin Gerstenberger, Günter K. Auernhammer, Karl A. Kalina, Markus Kästner

A PREPRINT

Heinrich T. Roth

Institute of Solid Mechanics

TU Dresden, 01069 Dresden, Germany

Matti Schneider

Institute of Engineering Mathematics

University of Duisburg-Essen, 45141 Essen, Germany

Lukas Jabs

Institute of Engineering Mathematics

University of Duisburg-Essen, 45141 Essen, Germany

Günter K. Auernhammer

Leibniz Institute of Polymer Research Dresden

01069 Dresden, Germany

Konstantin Gerstenberger

Leibniz Institute of Polymer Research Dresden

01069 Dresden, Germany

Karl A. Kalina

Institute of Solid Mechanics

TU Dresden, 01069 Dresden, Germany

Markus Kästner ∗^{*}

Institute of Solid Mechanics

TU Dresden, 01069 Dresden, Germany

October 15, 2026

ABSTRACT

Anisotropic magnetorheological elastomers are magnetoactive smart materials whose complex magneto-mechanical behavior is strongly influenced by their underlying microstructure. Efficient and accurate multiscale simulations of these materials rely on small unit cells that reproduce the behavior of the real material. In this work, we present a framework for the generation and validation of such two-dimensional representative volume elements (RVEs) from a given microstructure image, assuming circular particles. The cells are generated through an optimization procedure where the two-point correlation function serves as a differentiable descriptor, while a minimum inter-particle distance is enforced as a constraint. To assess the equivalence of the generated cells, we compare their effective magneto-mechanical response with those of the reference microstructure. We demonstrate that the generated cells reproduce the reference response with high accuracy, also with substantially fewer particles. Consequently, the computational cost of subsequent multiscale simulations is reduced.

Keywords Microstructure generation · Descriptor · Anisotropy · Magnetorheological elastomers · Finite strain magneto-elasticity · Computational homogenization

1 Introduction

Magnetorheological elastomers (MREs) are magnetoactive smart materials whose mechanical properties and shape can be adapted by an external magnetic field [1, 2, 3]. This field-dependent behavior enables a broad range of applications: MREs serve as actuators [4, 5], for example as magnetically actuated lamellae [6] or tubes [7] for object transport and as valves [8], as well as in magnetically driven robots [9, 10]. They are also used in sensors such as acceleration sensors [11, 12] and magnetometers [13]. Furthermore, their adjustable stiffness is utilized in adaptive dampers [14, 15, 16, 17].

Structurally, an MRE is a composite material consisting of a mechanically soft elastomeric matrix filled with stiff magnetic particles. The particles are called magnetically hard in case they exhibit a magnetic hysteresis and soft otherwise. In most applications, carbonyl iron powder (CIP) with a particle diameter of approximately 5 μ\mum is used as the soft-magnetic phase [1]. For research purposes, larger nickel particles with a

∗^{*}Corresponding author, email: markus.kaestner@tu-dresden.de.

A PREPRINT

more regular shape and diameters of 50 μ\mum and above are also used [18, 19].

The particle arrangement within the matrix determines the resulting material behavior. If no magnetic field is applied during crosslinking of the elastomer, then the particles remain randomly distributed, yielding an isotropic MRE. Conversely, if a magnetic field is applied while the matrix is curing, then the particles align into chain-like structures, resulting in an anisotropic, structured MRE. The effective magneto-mechanical behavior depends strongly on this particle arrangement and is therefore of particular interest [20, 21].

The effective behavior of complex heterogeneous materials is commonly obtained by solving the governing field equations within a continuum formulation. For a sample or part made from an MRE, however, a direct finite element (FE) simulation resolving the entire microstructure that may contain millions of particles entails a prohibitive computational effort. The effort may be reduced by using the theory of homogenization, which makes it possible to predict the effective response of a composite from knowing the microstructure and the behavior of the phases. In a coupled multiscale scheme [22, 23, 24] only a small portion of the microstructure, a representative volume element (RVE) [25], is simulated and the local fields are homogenized [26] to obtain the effective behavior for the macroscopic simulation. A decoupled multiscale scheme [27, 28, 29] may be even faster: a macroscopic material model is calibrated on homogenized RVE data and then used in the macroscopic simulations. In both the coupled and decoupled cases, the volume element should be as small as possible while still being large enough to be representative of the microstructure. The use of a periodic RVE together with periodic boundary conditions is additionally favorable for achieving representativity [30, 31].

The field of microstructure generation aims to generate unit cells that exhibit prescribed morphological features, which may be quantified by a descriptor [32, 33]. The generation may be formulated as an optimization problem, in which a unit cell is obtained by minimizing the error between its descriptor and the descriptor of a reference microstructure. A commonly used descriptor is the two-point correlation (TPC), which characterizes the spatial neighborhood relations between the phases of a microstructure [34, 35]. Since it does not presuppose a particular microstructure geometry, the TPC is applicable to a broad range of heterogeneous materials. In certain settings, however, descriptors tailored to the specific microstructure at hand have proven effective for generation [36, 37]. In many cases, the microstructure is simply described by pixels or voxels. Since the number of parameters is given by the number of pixels or voxels, the generation of larger cells is computationally expensive, even with gradient-based optimization approaches [38, 39]. Furthermore, it is not guaranteed that the resulting cell satisfies certain conditions on the shape, size, and minimum distance between particles, which might complicate subsequent microscale FE simulations.

To avoid these drawbacks, we take the efficient and differentiable formulation of the TPC for ellipsoidal particles, introduced by Seibert et al. [40], as our starting point. Relying on simple geometric shapes, this formulation allows us to constrain the range of particle sizes and distances, while at the same time significantly reducing the number of optimization parameters. This paper presents a method to generate two-dimensional statistically equivalent unit cells from a given two-dimensional microstructure image using the TPC as the given descriptor. To validate the statistical equivalence between generated and reference cells, we compare their effective magneto-mechanical behavior.

Remark 1. Although real microstructures are three-dimensional and their particles approximately spherical, a fully three-dimensional treatment is computationally demanding. The present work therefore adopts a two-dimensional formulation as a simplified model system, in which particles are represented as circles, corresponding to infinitely long cylinders in three dimensions. This reduces the computational cost and enables faster evaluation while retaining the essential methodological aspects. Because geometric constraints and particle interactions differ in three dimensions, the quantitative results cannot be expected to transfer directly. The methodology itself, however, should be transferable to three-dimensional microstructures with appropriate modifications.

This work is outlined as follows. Sec. 2 introduces the two-point correlation function as a descriptor and describes the microstructure generation procedure. The underlying equations for the magneto-mechanical microscale simulations and the homogenization are presented in Sec. 3. In Sec. 4, a microstructure image is employed to generate unit cells, and their effective behavior is subsequently compared. Finally, Sec. 5 summarizes the results and outlines future steps.

Notation. Throughout this work, indices carry four different meanings depending on the context.

Tensor indices are denoted by Greek letters and label the components of a tensor with respect to a chosen Cartesian basis, e.g., a=∑α=1ndimaαeα\boldsymbol{a} = \sum_{\alpha=1}^{n_{\mathrm{dim}}} a_{\alpha} \boldsymbol{e}_{\alpha} and A=∑α,β=1ndimAαβeα⊗eβ\mathbf{A} = \sum_{\alpha, \beta=1}^{n_{\mathrm{dim}}} A_{\alpha\beta} \boldsymbol{e}_{\alpha} \otimes \boldsymbol{e}_{\beta}, where ndim∈{2,3}n_{\mathrm{dim}} \in \{2, 3\} is the spatial dimension. First-order tensors are written in italic bold ( a\boldsymbol{a}), second-order tensors in upright bold ( A\mathbf{A}), and fourth-order tensors in blackboard bold ( A\mathbf{A}). The Einstein summation convention is not employed; all summations are stated explicitly. A non-tensorial quantity associated with the spatial direction eα\boldsymbol{e}_{\alpha}, such as the edge length of a cube aligned with the coordinate axes, is denoted by a(α)a_{(\alpha)}.

The single contraction is defined as a⋅b=∑αaαbα\boldsymbol{a} \cdot \boldsymbol{b} = \sum_{\alpha} a_{\alpha} b_{\alpha} and A⋅B=∑α,β,γAαβBβγeα⊗eγ\mathbf{A} \cdot \mathbf{B} = \sum_{\alpha, \beta, \gamma} A_{\alpha\beta} B_{\beta\gamma} e_{\alpha} \otimes e_{\gamma}, the double contraction as A:B=∑α,βAαβBβα\mathbf{A} : \mathbf{B} = \sum_{\alpha, \beta} A_{\alpha\beta} B_{\beta\alpha}, and the cross product as a×b=∑α,β,γeαβγaαbβeγ\boldsymbol{a} \times \boldsymbol{b} = \sum_{\alpha, \beta, \gamma} e_{\alpha\beta\gamma} a_{\alpha} b_{\beta} e_{\gamma} with the Levi–Civita symbol eαβγe_{\alpha\beta\gamma}. The dyadic product is denoted by the symbol ⊗\otimes.

A second-order tensor admits the additive decompositions A=dev(A)+sph(A)=sym(A)+skw(A)\mathbf{A} = \text{dev}(\mathbf{A}) + \text{sph}(\mathbf{A}) = \text{sym}(\mathbf{A}) + \text{skw}(\mathbf{A}) into its deviatoric part dev(A)=A−13tr(A)1\text{dev}(\mathbf{A}) = \mathbf{A} - \frac{1}{3} \text{tr}(\mathbf{A}) \mathbf{1} and its volumetric part sph(A)=13tr(A)1\text{sph}(\mathbf{A}) = \frac{1}{3} \text{tr}(\mathbf{A}) \mathbf{1}, as well as into its symmetric part sym(A)=12(A+AT)\text{sym}(\mathbf{A}) = \frac{1}{2} (\mathbf{A} + \mathbf{A}^T) and skew-symmetric part skw(A)=12(A−AT)\text{skw}(\mathbf{A}) = \frac{1}{2} (\mathbf{A} - \mathbf{A}^T). The trace and determinant of a second-order tensor are denoted by tr(A)=∑αAαα\text{tr}(\mathbf{A}) = \sum_{\alpha} A_{\alpha\alpha} and det⁡(A)\det(\mathbf{A}), respectively.

A PREPRINT

Using the nabla operator ∇\nabla, the gradient ∇XA=∑αeα⊗∂A∂Xα\nabla_X \mathbf{A} = \sum_\alpha \mathbf{e}_\alpha \otimes \frac{\partial \mathbf{A}}{\partial X_\alpha}, divergence ∇X⋅A=∑αeα⋅∂A∂Xα\nabla_X \cdot \mathbf{A} = \sum_\alpha \mathbf{e}_\alpha \cdot \frac{\partial \mathbf{A}}{\partial X_\alpha}, and curl ∇X×A=∑αeα×∂A∂Xα\nabla_X \times \mathbf{A} = \sum_\alpha \mathbf{e}_\alpha \times \frac{\partial \mathbf{A}}{\partial X_\alpha} are defined with respect to the reference coordinates XαX_\alpha. The corresponding operators ∇A\nabla \mathbf{A}, ∇⋅A\nabla \cdot \mathbf{A}, and ∇×A\nabla \times \mathbf{A} are defined analogously with respect to the current coordinates xαx_\alpha. Finally, the norm ∥a∥=∑αaαaα\|\mathbf{a}\| = \sqrt{\sum_\alpha a_\alpha a_\alpha} and ∥A∥=∑α,βAαβAαβ\|\mathbf{A}\| = \sqrt{\sum_{\alpha, \beta} A_{\alpha\beta} A_{\alpha\beta}} applies to both tensors and arrays.

Array indices are denoted by l,ql, q, e.g.,

a‾=[a1,…,al,…,an]\underline{a} = \left[a_1, \ldots, a_l, \ldots, a_n\right] with l∈{1,…,n}l \in \{1, \ldots, n\} referring to elements of arrays of size n∈Nn \in \mathbb{N}, which do not possess the transformation properties of a tensor.

Grid indices in real space are denoted by u, v and enumerate the values of a field at discrete spatial grid points, e.g., au=a(ru)a_u = a(\boldsymbol{r}_u) is the scalar value of the field a at the point ru\boldsymbol{r}_u.

Grid indices in Fourier space are denoted by j,k,s,tj, k, s, t and enumerate quantities at discrete frequencies in Fourier space, e.g., a^j=a^(ωj)\hat{a}_j = \hat{a}(\omega_j) is the Fourier coefficient for the wave vector ωj\omega_j.

Although these conventions are given here for a single index, they extend to several indices by adding further underlines. Arrays of tensors are likewise admissible, e.g., a‾=[a1,…,al,…,an]\underline{a} = [a_1, \ldots, a_l, \ldots, a_n] with the indices alαa_{l\alpha}.

References (23)