arXiv:2610.20397cs.CVOct 2026

Manuscript Offprint

arXiv:2610.20397

Where Should the Gaussians Go? Reusable Label-Aware Allocation for Budget-Constrained Gaussian Splatting of Cinematic CT

Bowen Xiang, Dingjie Su, Jon S. Heiselman, Michael I. Miga

Graphical abstract

14 Oct 2026

A real-time display can afford only B Gaussians. Where should they go?

Figure

CT + labels + TF

Label-aware allocation front end

learned once from optimised scenes; no per-patient optimisation

Neural prior (3D U-Net)

VACF (closed form)

ac=Vc⊤∑kwkfk,ca_c = V_c^\top \sum_{k} w_k f_k, c

Figure

density over 2 mm cells

Figure

exactly B positions

Attribute fitting (per patient)

Figure

real-time splatting

[cs.CV]

Figure

uniform 32.1 dB

ours 37.0 dB

error at B=10KB = 10K, same fitting

Equal budget

vessel PSNR +4.5 to +7.1 dB

over uniform placement;

thin vessels resolved

Close to the optimum

neural prior ≈ per-patient optimised

allocation on vessels, in held-out

and external patients

Better starting point

position optimisation from VACF beats

densification on vessels at 10K;

at 25K: 118 s vs 248 s