arXiv:2610.20432cs.CVOct 2026

Manuscript Offprint

arXiv:2610.20432

Infant Fingerprints: Quality Assessment & Recognition

João L. H. Dall Agnol, Dalcimar Casanova, Rodrigo Minetto, Luiz F. P. Southier, Marcelo Teixeira, Marcelo Filipak, Anil K. Jain

João L. H. Dall Agnol, Dalcimar Casanova, Rodrigo Minetto, Luiz F. P. Southier, Marcelo Teixeira, Marcelo Filipak, and Anil K. Jain

Abstract—Infant fingerprint recognition is hindered by a combination of physiological characteristics, such as small ridge width and spacing, and acquisition challenges that include involuntary motion, skin residue, and uneven fingertip pressure. These factors undermine fingerprint quality standards originally designed for adults, which assume feature distributions that do not hold for infants. To address this gap, this paper evaluates ten fingerprint quality assessment methods on a longitudinal dataset that spans six age groups from newborns to three months, alongside a parameter tuning routine that uncovers age-specific fingerprint characteristics to recalibrate methods with domain-dependent assumptions. Both default and tuned configurations are compared through recognition experiments assessing the effectiveness of quality-guided gallery selection. Template-fusion strategies and latent fingerprint recognition technologies are further examined to identify the best possible matching rates achievable by the top-performing method. Results show that tuned parameter sets outperform default configurations for the majority of methods and age groups, indicating that targeted recalibration of existing frameworks improves gallery utility and contributes to more reliable infant fingerprint recognition.

Index Terms—Infant Biometrics, Infant Fingerprint, Quality Assessment, Parameter tuning, Longitudinal Analysis

Figure

• Resolution: ≥\geq 5,000 DPI

• Technology: Glass prism

• Certification: FBI FAP 10

Fig. 1: Infant fingerprint acquisition process: top-left shows capture procedure used for the UTFPR-IFD dataset [5]; top-right contains examples of fingerprint video frames obtained from a single newborn fingerprint; bottom shows the InfantID scanner used to acquire the images, alongside its key characteristics such as sampling rate and technology [6].

I. INTRODUCTION

Infant and adult fingerprints exhibit substantially different structural patterns. Infant ridges are markedly thinner and inter-ridge spacing may be up to four times smaller [1], [2], which directly motivates the use of high-resolution (1200-5000 PPI) scanners to preserve sufficient discriminative detail for recognition [1]-[5]. In addition, infant fingers are softer and more elastic than those of adults, increasing susceptibility to deformation during image capture [3]. Figure 1 illustrates the acquisition process, alongside sample images that exhibit common capture degradations, including motion and residual contaminants such as lint and fiber residues.

Solutions aiming to provide infants with reliable recognition systems must grapple with these physiological challenges; particular to this work is the problem of defining an acceptance criteria in structural conformity to quantify the quality of an infant fingerprint sample. In other words, the properties that constitute an acceptable sample for adult fingerprints may not hold for infants, and the structural bounds that define ridge and valley conformity must be reconsidered according to the subject's age.

Quality assessment plays a critical role within the biometric pipeline. By bridging the capture and processing stages, it influences the reliability of all subsequent operations. For adult biometrics, fingerprint quality assessment has been extensively investigated over the past decades, leading to the development of standardized methodologies such as ISO/IEC 29794-1 [7] and the widely adopted National Institute of Standards and Technology (NIST) Fingerprint Image Quality 2 (NFIQ2) package [8], which is integrated into modern comparators such as VeriFinger [9]. In contrast, quality assessment for infants is a relatively unexplored area, remaining largely restricted to the direct application of NFIQ (1 and/or 2) to infant fingerprint data [1], [10], [11]. Recent works on the topic of infant biometrics have focused on producing alternative high-resolution scanners [2], [3] and the development of image enhancement techniques, including binarization [12], [13] and super-resolution methods [4], [14].

To address fingerprint quality assessment for infants, this study reviews established ISO/IEC 29794-1 [7] methods and more recent advancements [8], [15], selected according to their primary underlying features (e.g., ridge spacing, orientation), to determine whether existing solutions can reliably identify informative infant fingerprint samples, and explores age-sensitive parameter search to improve recognition rates. Both standard and tuned configurations are evaluated through a gallery selection problem: given a set of images from an identity, methods must rank samples according to their matching potential — a property commonly formalized in

João Leonardo Harres Dall Agnol, Dalcimar Casanova, Rodrigo Minetto, Luiz Fernando Puttow Southier, Marcelo Teixeira, and Marcelo Filipak are with the Federal University of Technology - Paraná (UTFPR), Brazil (e-mails: joaoleonardoagnol@alunos.utfpr.edu.br, dalcimar@utfpr.edu.br, rminetto@utfpr.edu.br, luizsouthier@utfpr.edu.br, mtex@utfpr.edu.br, and mfilipak@alunos.utfpr.edu.br).

Anil Kumar Jain is with Michigan State University, East Lansing, MI, USA (e-mail: jain@cse.msu.edu).

terms of utility for identification systems [16]. Experiments are repeated for six age-based subsets, spanning from newborns to three months of age, drawn from the UTFPR-IFD [5] longitudinal infant database.

The main contributions of this paper are as follows:

(i) We review and evaluate ten fingerprint quality assessment methods, encompassing classical signal-processing, structure-driven, and learning-based approaches, that capture complementary fingerprint properties through both local and global image features.

(ii) A systematic parameter search routine is introduced to identify optimal infant ridge and valley property (width, distance, etc) ranges. This process is performed independently for each parameter-dependent method and age group, aiming to maximize the biometric utility of galleries selected through quality ranking.

(iii) To assess the effectiveness of quality-driven fingerprint selection across age groups, identity galleries are composed using the top-ranked samples selected by each quality assessment method, separately. Using VeriFinger 2025.2 [9], quantitative and qualitative analyses compare standard and optimized parameter configurations for infant fingerprints.

(iv) A complementary analysis examines a practical deployment scenario, combining a template-fusion strategy with a state-of-the-art latent comparator (MegaMatcher 2025.2 [9]) to investigate the best possible matching rates achieved by a top-performing quality method identified in this study.

To the best of the authors’ knowledge, this is the first study to evaluate and tune fingerprint quality assessment methods in the context of infant biometrics.

This paper is structured as follows: Section II reviews related work, including quality assessment methods evaluated for parameter optimization in infant fingerprint recognition, as described in Section III. Section IV evaluates the impact of these methods on recognition performance, with and without tuned parameters; finally, Section V discusses the implications of these findings, and Section VI summarizes the contributions and outlines future research directions.

References (33)