VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

ABSTRACT

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

1 INTRODUCTION

Medical image super-resolution (SR) aims to recover image detail from low-resolution observations while preserving anatomically meaningful structure. This is particularly challenging for contrast-enhanced vascular CT, where vessels are thin, highly branched, and span a wide range of diameters and curvatures: small peripheral branches may additionally exhibit weak contrast against surrounding tissue (Lesage et al., 2009). At high upsampling factors, much of this fine image detail is poorly determined by the observed low-resolution image, making the reconstruction inherently ambiguous (Ledig et al., 2017).

Recent deep SR has progressed from deterministic regression to generative reconstruction, enabling sharper and more realistic image detail (Zhang et al., 2018b; Liang et al., 2021; Ledig et al., 2017; Saharia et al., 2023; Yue et al., 2023). However, visual plausibility does not guarantee anatomical fidelity. Errors that are small in image space can be structurally significant: a short discontinuity may disconnect an otherwise continuous vessel tree, while a spurious connection may alter its branching structure. Such failures are not well characterized by conventional image-quality metrics. High SSIM, for example, can coexist with hallucinated anatomical structures in medical reconstruction (Muckley et al., 2021), and improved image-quality metrics do not necessarily translate to better downstream detection performance (Li et al., 2021). Deep-learning-based CT reconstruction may also blur or remove small vessels despite producing visually high-quality images (Koetzier et al., 2023). For tubular structures in particular, voxel-wise overlap alone does not fully characterize topological correctness, motivating connectivity-aware measures such as clDice (Shit et al., 2021). A reconstructed CT image can therefore appear locally plausible while still containing broken, missing,

*Equal contribution. †Work partially done at the University of California, San Diego. Correspondence to: Jiahe Huang chh118@ucsd.edu and Rose Yu roseyu@ucsd.edu.

Figure

Figure 1: Overview of VascuSR. Starting from an initial SR estimate, the recovered HV/PV anatomy is refined in three dimensions and fed back through a lightweight anatomy controller to condition the next diffusion-based reconstruction. Repeating this process for K feedback rounds progressively couples image super-resolution with volumetric vascular refinement.

or incorrectly connected vessels. These challenges motivate explicitly incorporating volumetric vascular structure into the reconstruction process, rather than relying on image appearance alone.

To address these limitations, we propose VascuSR, an iterative anatomy-aware diffusion framework for CT SR that targets both image fidelity and vascular anatomical plausibility. Rather than relying only on individual 2D slices, VascuSR represents vascular anatomy explicitly in 3D. This representation provides richer information about vascular topology while separating vascular structure from CT intensity and organ texture, making anatomical refinement a simpler learning task. We therefore use a conditional 3D rectified flow to refine the vascular representation. A lightweight multi-scale anatomy controller then transforms the refined representation into conditioning features for the diffusion decoder. At each round, the vascular representation is re-extracted and refined from the latest SR volume to guide the next reconstruction, so that the anatomical condition and SR output are updated in turn through the feedback loop.

Our contributions are threefold:

• We introduce explicit 3D vascular representations as anatomical guidance for slice-wise CT super-resolution. Separating vascular refinement from image reconstruction simplifies structural learning while retaining HR supervision for image fidelity.

• We develop an iterative refinement–conditioning mechanism that combines a conditional 3D rectified-flow vascular refiner with a lightweight multi-scale anatomy controller, allowing anatomical guidance to adapt to each updated SR volume.

• We evaluate VascuSR on two public vascular CT datasets across image quality, vascular overlap, and three-dimensional vascular structure. VascuSR reduces class-averaged component counts by over 20% on both datasets and class-averaged MCD by over 10% on MSD, while comparisons with direct joint optimization support the benefits of the decoupled design.