arXiv:2610.20815eess.SYOct 2026

Manuscript Offprint

arXiv:2610.20815

A Response to the Reply Presented in "A Fair Comparison of Sliding-Mode and Immersion-and-Invariance Observers"

Luis Cervantes-Pérez, Víctor Santibáñez, Jesús Sandoval, Romeo Ortega, José Guadalupe Romero

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original. This text is shared under the same licence.

Abstract

In response to the reply presented in [Muñoz-Vázquez and Sánchez-Torres(2026)], this technical report extends the experimental evaluation of position-feedback velocity observers and adaptive tracking controllers for a pendular system with nonlinear friction reported in [Cervantes-Pérez et al.(2026)]. The immersion-and-invariance (I&I) adaptive control scheme proposed in [Romero et al.(2025)], whose gains are tuned according to the guidelines presented in [Ortega et al.(2025)], is compared with a control scheme employing the adaptive modified super-twisting observer of [Dávila et al.(2006)], whose observer gains are selected according to the guidelines proposed in [Muñoz-Vázquez and Sánchez-Torres(2026)]. Although these “tuning guidelines” attenuate chattering in certain scenarios, the experimental results reported here show that they do not eliminate it in general.

1 Experimental platform and scope

This section introduces the experimental platform used to conduct the comparative study and outlines the scope of the reported tests. The testbed consists of a direct-drive pendular device with a single vertical link, designed and built at the La Laguna Technological Institute, Mexico. A picture of the pendular device is shown in Figure 1, whereas its schematic diagram is presented in Figure 2, where q denotes the angular position of the actuated joint.

The joint is actuated by a direct-drive motor manufactured by Yokogawa Electric Corporation, model DM1A200G. The motor operates in torque mode, providing a maximum torque of ±200\pm200 [Nm]. It is also equipped with a relative encoder offering a resolution of 1,024,000 pulses per revolution. The proposed controller was implemented digitally in MATLAB using the Simulink Desktop Real-Time environment, with a sampling period of 1 [ms]. The experiments were conducted on a PC running Windows 10, equipped with an Intel Core i5-14600K CPU, 32 GB of RAM, an RTX 3060 GPU, and a 512 GB M.2 SSD. Communication between the PC and the robot was established through a Sensoray 626 data acquisition card (DAQ) installed in the PCI port of the motherboard. The DAQ interfaced with the motor driver (PARKER COMPUMOTOR model DMG3-1200A) by sending analog voltage signals corresponding to the control torques. In turn, the driver transmitted pulse trains replicating the motor encoder signals to the DAQ digital inputs. The physical parameters of the link are listed in Table 1, as originally reported in [Gamez-

Table 1: Physical parameters of the pendular device.

DescriptionNotationValueUnits
Length of Linkll0.313m
Distance to the center of masslbl_b0.0641m
Mass of Linkmm22.4466Kg\text{K}_g
Inertia relative to center of massJJ0.7013Kg m2\text{Kg m}^2
Viscous friction coefficientθ1\theta_15.317Nm s/rad
Coulomb friction coefficientθ2\theta_211.6403Nm
Gravity acceleration constantgg9.81ms2\frac{\text{m}}{\text{s}^2}

Figure

Figure 1: Pendular device.

Herrera et al.(2025), Gandarilla et al.(2022)]. The table summarizes the meaning of the parameters and their numerical values, where ll denotes link length, and 'Dist.', 'Inert.', and 'com' stand for distance, inertia, and center of mass, respectively.