Manuscript Offprint

arXiv:2610.21266

TRACER: A Multimodal Harness for Patient Care in Hospitals

Zane Durante, Paul Tang, Keshigeyan Chandrasegaran, Amit Kaushal, Shrinidhi Kowshika Lakshmikanth, Feolu Kolawole, Yu Jun Zheng, Yifan Geng, Shobhit Agarwal, Kevin Schulman, Juan Carlos Niebles, Ehsan Adeli, Arnold Milstein, Li Fei-Fei

ABSTRACT

Continuous video and clinical records provide complementary information for understanding how patient behavior evolves over a hospital stay. A central challenge is how to represent behavior across the entire stay while preserving access to fine-grained visual and clinical evidence. We introduce TRACER, a training-free multimodal harness that constructs minute-level action records from video and combines them with clinical records into hourly reports. The harness equips an LLM agent with tools to query this hierarchy, inspect relevant video, and retrieve clinical records. To evaluate TRACER, we construct two benchmarks. The first contains 397 annotated one-minute clips spanning 15 atomic actions; the second poses 144 clinician-informed multiple-choice questions, grounded in 264 hours of video and clinical records from two ICU patients. TRACER achieves up to 84.8% accuracy for action detection and 61.0% QA accuracy versus 49.3% for the strongest baseline using the same backbone. Across 280 patients spanning approximately 60,000 camera-hours, TRACER identifies significantly less purposeful activity in patients with a positive delirium assessment during their stay than in those without (p < 0.0001). Our results show that combining continuous video with clinical records can support understanding of patient behavior over time and across patient cohorts without training on protected health data.

1 INTRODUCTION

Reasoning over long, continuous streams of visual observations is important for understanding human behavior. Recent advances in long-form video understanding have improved vision-language models' (VLMs) ability to recognize, summarize, and reason about events and activities over increasingly long visual contexts (Chandrasegaran et al., 2024; Fu et al., 2024; Wu et al., 2024; Zhang et al., 2025; Yang et al., 2025). However, understanding real-world human behavior often requires integrating visual observations with external information. This need is particularly important in healthcare, where behavioral changes provide evidence about a patient's condition but must be interpreted within the context of their medical history and ongoing treatment. In this work, we study this problem in the intensive care unit (ICU), a high-stakes environment where continuous video and clinical records together capture changes in patient movement, responsiveness, interaction, and care across days (Devlin et al., 2018).

Developing this capability in the ICU presents several technical challenges. Long-context vision-language models and caption-based pipelines offer approaches for long-form video understanding (Chandrasegaran et al., 2024; Zeng et al., 2023), but applying them across entire ICU stays requires balancing temporal coverage with access to detail. Specifically, a system must be able to connect brief movements and interactions to behavioral patterns extending across days. And while bedside video captures observable activity and interactions, electronic health records (EHRs) document clinical assessments and interventions that provide complementary behavioral context. Finally, acquiring continuous bedside recordings linked to EHRs requires dedicated sensing infrastructure and secure handling of sensitive patient information; the recordings and clinical records used in our

Figure

Figure 1: Overview of TRACER. TRACER equips an agent model with hierarchical behavioral representations and tools for understanding multi-day ICU patient trajectories. Vision–language models analyze one-minute bedside video segments to detect atomic actions defined by a clinically informed taxonomy and generate descriptive captions. These outputs are combined with concurrent medication records to generate structured hourly behavioral reports. Through report, timeline, video, and EHR tools, the agent iteratively retrieves evidence and examines relevant video segments to answer retrospective clinical questions. Our evaluation suite assesses atomic action detection on 397 annotated one-minute clips and longitudinal clinical reasoning on 144 multiple-choice questions spanning 264 hours of continuous video.

study cannot be released publicly. We therefore seek a method for longitudinal understanding that can be shared without releasing protected patient records or model parameters fitted to them.

To address these challenges, we introduce TRACER (Trajectory Reasoning Across Clinical Event Records), a training-free multimodal harness for understanding multi-day ICU patient trajectories. TRACER separates temporal abstraction, which builds a hierarchy of minute- and hour-level records continuously as the stay is recorded, from evidence acquisition, in which an agent reasons over these compact records and accesses the raw video and EHR as needed. To construct this hierarchy, vision-language models (VLMs) analyze one-minute video segments zero-shot, producing atomic action detections under a clinically informed taxonomy together with descriptive captions. A language model combines these outputs with concurrent medication records to generate structured hourly behavioral reports. The atomic action records supply consistent variables for aggregation and comparison, while captions and reports provide descriptive context beyond the predefined categories. A tool-equipped agent model can then retrieve reports, compare action predictions across time, query clinical records, and request targeted visual analysis of selected video segments, enabling retrospective investigation (see Figure 1).

We evaluate TRACER using recordings and linked EHR data collected over four years at Stanford Hospital. We examine the accuracy of local perception, the use of these observations for longitudinal reasoning, and the clinical relevance of cohort-level behavioral predictions. On our benchmark of 397 manually annotated one-minute clips from 26 patient stays, TRACER achieves up to 84.8% accuracy and 68.6 micro-F1 across 15 atomic action categories. To probe reasoning over patient trajectories, we introduce TRAJECTORY-144, a clinician-informed benchmark of 144 multiple-choice questions grounded in video and clinical records from two patient stays spanning 264 hours of continuous video and EHR data. TRACER reaches 76.9% QA accuracy with the best proprietary LLM agent and 67.9% QA accuracy for the best open-weight LLM agent, while no long-context VLM or Socratic caption baseline (Zeng et al., 2023; Chandrasegaran et al., 2024) exceeds 50%. Finally,

Table 1: MCQ performance on TRAJECTORY-144. QA accuracy (%) is shown by question type and is averaged over 5 gold-answer placements. TRACER rows share an identical harness (prompts, taxonomy, and temporal hierarchy) and differ only in the agent model. Best per column is in bold, and second best is underlined. The video tool is served by the agent model, or by Gemini 3.1 Flash Lite where marked †^{\dagger} .

VideoEHRCross-modalAvg.
No video
Random20.120.020.020.1
Text-only LLM, Gemini 3.1 Flash Lite32.326.925.030.9
Long-context VLMs
Qwen3-VL 8B, 475 frames31.610.047.528.6
Qwen3-VL 8B, 950 frames36.313.850.033.0
Gemini 3.1 Flash Lite, 950 frames36.514.625.031.9
Gemini 3.1 Flash Lite, 475 frames + EHR41.883.840.049.3
Socratic models (HourVideo)
Qwen3-VL 8B33.722.320.030.9
Qwen3.5 9B30.418.510.027.1
Gemini 3.1 Flash Lite36.816.247.533.7
Gemini 3.1 Flash Lite + EHR37.876.242.545.0
TRACER harness (ours)
w/ gpt-oss-20b†^{\dagger}50.393.140.057.4
w/ Qwen3.5 9B49.595.452.557.9
w/ Gemini 3.1 Flash Lite53.996.245.061.0
w/ Gemma-4 31B†^{\dagger}61.8100.047.567.9
w/ Gemini 3.5 Flash72.099.272.576.9

we apply TRACER across a cohort of 280 patients spanning approximately 60,000 camera-hours and detect significantly lower frequencies of purposeful activities among patients with a positive delirium assessment during their stay, indicating that TRACER can quantify clinically relevant behavioral differences between patient groups.

References (37)