A 2D Image Feedback-Based Autonomous Endovascular Navigation Method: A Perception and Control Framework

Sheng Cao, Shuxiang Guo, Yonggan Yan, Jian Guo, Chunying Li, Bin Wang, Mingchao Ding, Yongxin Zhang, Yongwei Zhang, Pengfei Yang, Jianmin Liu

Sheng Cao, Shuxiang Guo, Fellow, IEEE, Yonggan Yan, Jian Guo, Chunying Li, Bin Wang, Mingchao Ding, Yongxin Zhang, Yongwei Zhang, Pengfei Yang, and Jianmin Liu

Abstract—In endovascular interventions, physicians rely on planar DSA and X-ray fluoroscopy to interpret vessel anatomy and device motion, yet converting these images into feedback for autonomous navigation remains difficult. A perception and control method is formulated for two-dimensional image feedback. Vessel masks are converted into a labeled centerline graph, and device-tip estimates are projected onto a planned path to obtain progress, deviation, and direction. A rule-based controller uses these quantities for delivery, branch selection, probing, rollback, and recovery. The method was evaluated on a physical dual-device robotic platform in 65 closed-loop runs using simulator-rendered planar images across three paths. All runs reached at least 0.95 maximum observed guidewire progress; two runs (3.1%) met the prespecified failure rule of three or more autonomous stop events. The results establish route-level performance on the tested platform; clinical image sequences and broader anatomy remain to be evaluated.

Index Terms—Image-based perception, device segmentation, visual state estimation, autonomous endovascular navigation, path-guided control, physical robotic validation.

I. INTRODUCTION

Endovascular intervention is a sequential decision problem observed through a planar projection. The clinical need

Research supported by the Shenzhen “Medical Engineering Integration” Special Support Program Project under Grant F-2024-Z99-502365, Shenzhen, China; in part by the High level of special funds from Southern University of Science and Technology under Grant G03034K003, Shenzhen, China. (Corresponding author: Shuxiang Guo.)

S. Cao is with the Beijing Institute of Technology, Beijing 100081, China, and also with the Advanced Institute for Ocean Research, Southern University of Science and Technology, Shenzhen, 518055, China, and also with the Shenzhen Institute of Advanced Biomedical Robot Company Limited, Shenzhen 518000, Guangdong Province, China.

S. Guo is with the Department of Electronic and Electrical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China, and also with the School of Life Science and the Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing 100081, China (e-mail: guo.shuxiang@sustech.edu.cn).

Y. Yan is with the School of Mechanical, Electronic and Control Engineering, Beijing Jiaotong University, Beijing, China.

J. Guo is with the Shenzhen Institute of Advanced Biomedical Robot Company Limited, Shenzhen 518000, Guangdong Province, China.

C. Li is with the Southern University of Science and Technology, Shenzhen, Guangdong 518055, China.

B. Wang and M. Ding are with Aerospace Center Hospital and the Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, Beijing Institute of Technology, Beijing 100081, China.

J. Liu, P. Yang, Y.-X. Zhang, and Y.-W. Zhang are with the Neurovascular Center, Changhai Hospital, Naval Medical University, Shanghai, China.

for reliable vascular intervention has motivated robotic assistance across vascular and neuroendovascular procedures [1]–[4]. Recent studies have also examined autonomous endovascular systems and embodied intelligence for image-guided intervention [5], [6]. During DSA or X-ray fluoroscopy, vessel anatomy, device–vessel contact, and depth are represented only indirectly in the image. Each device command changes the configuration that produces the next image, so autonomous navigation requires a state that remains useful under incomplete and changing observations.

Local image cues do not uniquely determine route-level intent. Existing fluoroscopic methods have addressed catheter segmentation and guidewire-pose tracking, but these measurements do not by themselves specify the intended route or the next action [7], [8]. A guidewire tip and its local tangent can be consistent with more than one branch, while projection overlap, occlusion, and segmentation jitter can change the apparent direction. A useful state must therefore preserve branch identity and progress along the selected route while suppressing pixel-level variation that is irrelevant to the next decision.

The path-relative representation used here provides this task-oriented abstraction. A vessel centerline is represented as a labeled topology graph, and the operator-selected route is parameterized by arc length. Projection of the guidewire and catheter tips onto the route yields progress, transverse deviation, directional consistency, and inter-device lag. The graph supplies discrete branch structure; arc length supplies continuous progress; and the residuals indicate whether the observation remains compatible with the intended motion. Static vessel topology is initialized and locked, whereas device measurements remain frame dependent. This factorization converts image observations into a state that can be inspected at every control transition.

Image-guided navigation studies have used local directional cues, learned policies, and short-horizon visual feedback [9]–[11]. Route progress, branch identity, and recovery conditions are not always explicit in these control states. A deterministic policy based on path-relative variables makes the cause of each advancement, probe, rollback, or recovery transition observable and allows run-level failures to be traced to image-derived conditions.

The formulation targets the macroscopic layer of endovascular autonomy: delivery along a selected route, simple branch choice, deviation correction, and recovery. The physical dual-device robot builds on prior multi-manipulator, autonomous-delivery, remote-control, and multi-device intervention platforms [12]–[15]. Force-related sensing, multimodal feedback, haptic interfaces, and steerable-catheter mechanisms provide complementary directions for extending the control state [16]–[19]. The Mentice platform provides repeatable planar projections for controlled validation. Two segmentation models, skeleton-based tip and direction estimation, topology-constrained route construction, and a deterministic state machine form the closed loop. At a junction, an alternating rotation scan is followed by a bounded advancement trial; the next image determines acceptance or rollback. Direct force measurement and three-dimensional reconstruction are not required for this route-level formulation.

The central contribution is a topology-constrained, path-relative state abstraction that converts planar device and vessel observations into interpretable progress and branch-decision variables for physical-robot navigation. Route-level behavior is evaluated over 65 runs on three paths, with explicit stop-based failure accounting and image-derived measurements reported throughout the control loop.

References (20)