arXiv:2610.21590cs.ROOct 2026

Manuscript Offprint

arXiv:2610.21590

A Flow-Theoretic Multimodal Control Framework Fusing Mental and Physical Engagement for Upper-Limb Rehabilitation

Jun Leng, Pengcheng Li, Hanze Wang, Shuxiang Guo, Junlin Jiang

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Jun Leng, Student Member, IEEE, Pengcheng Li, Senior Member, IEEE, Hanze Wang, Student Member, IEEE, Shuxiang Guo, Fellow, IEEE, and Junlin Jiang, Student Member, IEEE

Abstract—While Assist-as-Needed (AAN) control aims to maximize user participation in robot-assisted training, existing methods relying solely on physical metrics cannot distinguish muscular inability from mental disengagement, leading to suboptimal interventions. To address this ambiguity, a Flow-theoretic multimodal AAN framework is proposed, fusing EEG-based mental engagement and sEMG-based physical engagement into an adaptive impedance control strategy. A four-quadrant fuzzy decision engine translates these dual physiological metrics into continuous control policies. This enables the upper-limb exoskeleton to inject feedforward assistance during intent-execution mismatch (e.g., motor output attenuation despite mental focus) and escalate guiding stiffness to penalize mental distraction. The framework was validated with healthy participants against a state-of-practice sEMG-only AAN baseline. Kinematically and mechanically, the proposed framework reduced robotic energy expenditure by 71.9% while maintaining precise trajectory tracking, confirming it elicited greater voluntary human effort. Physiologically, the system increased the time spent in the neuroplasticity zone (Flow State Ratio) from 4.6% to 42.8%. These results validate that decoupling and jointly regulating mental and physical states enhances the selectivity of robotic assistance, mitigating user passivity and sustaining the engagement crucial for motor learning.

Index Terms—flow theory, multimodal physiological sensing, Assist-as-needed (AAN), upper limb rehabilitation.

I. INTRODUCTION

UPPER limb movement dysfunction caused by neurological injuries, such as stroke, severely impairs an individual's ability to perform Activities of Daily Living (ADLs) and significantly reduces quality of life [1]. Modern neurorehabilitation relies on promoting patients' active participation in high-intensity, repetitive training to stimulate neuroplasticity and facilitate functional recovery [2]. To address these rigorous demands, robot-assisted therapy provides consistent, quantifiable training that directly complements traditional therapist-led methods [3], [4]. These systems offer precise physical guidance while reducing the labor burden on clinicians, making them essential for delivering the high-dosage therapy required for motor learning.

To maximize therapeutic outcomes, the field has widely adopted the “Assist-as-Needed” (AAN) paradigm. The core principle of AAN is to minimize robotic intervention, providing assistance only when the user cannot complete the movement independently. This approach aims to ensure maximal active effort [5]. However, accurately inferring the user’s true “need” remains a critical challenge. Traditional AAN strategies rely heavily on physical performance metrics, such as kinematic error or interaction force. For instance, Han et al. [6] proposed an adaptive control method that infers movement intention by decomposing real-time interaction forces. The system then adjusts the robot’s impedance parameters to promote active participation. More recently, researchers have integrated surface Electromyography (sEMG) to incorporate physiological effort into the control loop. Xu et al. [7], for example, developed a framework that adapts training trajectories and robotic assistance based on sEMG-derived muscle activation. This system encourages patient participation by modulating feedback gains. However, while such approaches successfully measure mechanical or muscular execution, they still fail to capture user’s mental focus. Although high-amplitude sEMG quantifies physical exertion, it cannot differentiate genuine task engagement from pathological co-contraction or abnormal compensatory synergies. Execution-level metrics alone fall short in revealing the user’s mental intent. Without monitoring mental focus, purely physical assistance strategies often fail to maintain an optimal training challenge, eventually leading to user passivity.

To resolve this ambiguity, integrating electroencephalography (EEG) into the control loop is essential for providing a direct measure of task-related attentional focus [8]. While EEG is widely applied in robotic rehabilitation, current paradigms mostly use it within Motor Imagery-based Brain-Computer Interfaces (MI-BCI) to decode discrete movement intentions [9], [10].

This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.

Manuscript received [ ]. This work was supported by the High Level of Special Funds from the Southern University of Science and Technology under Grant G03034K003, and in part by the Shenzhen “Medical Engineering Integration” Special Support Program Project under Grant F-2024-Z99-502365. (Corresponding authors: Pengcheng Li; Shuxiang Guo.)

This paper introduces an adaptive control framework grounded in Flow Theory to map these multidimensional physiological signals into actionable robotic interventions. Classic Flow Theory defines an optimal mental state as a balance between external task challenge and intrinsic user skill [11], [12]. The modern four-quadrant extension categorizes user experience into Flow, Anxiety, Boredom, and Apathy based on these misalignments [13]. In robot-assisted training, keeping users within this flow state mitigates both task-induced anxiety.

Jun Leng, Pengcheng Li, Hanze Wang, Shuxiang Guo, and Junlin Jiang are with the Department of Electronic and Electrical Engineering, Southern University of Science and Technology, Shenzhen 518055, China (e-mail: lengj2024@mail.sustech.edu.cn, lipc@sustech.edu.cn; guo.shuxiang@sustech.edu.cn).

Shuxiang Guo is also with the Aerospace Center Hospital, School of Life Science, and the Key Laboratory of Convergence Medical Engineering System and Healthcare Technology, Ministry of Industry and Information Technology, Beijing Institute of Technology, Beijing 100081, China.

and under-stimulated boredom [14], [15]. This equilibrium sustains intrinsic motivation and facilitates motor learning [16].

Most existing flow-aware systems rely on predefined task difficulties or intermittent self-reporting, limiting their real-time adaptability. Directly quantifying the abstract Challenge and Skill axes in real-time is also highly impractical during dynamic robot-assisted training, as the user's motor capabilities fluctuate continuously due to fatigue and varying physical demands. To address this gap, the proposed framework bypasses the direct measurement of classic Flow coordinates. It instead establishes a two-dimensional physiological diagnostic space using mental engagement ( sme∗s_{me}^{*}, via EEG) and physical engagement ( spe∗s_{pe}^{*}, via sEMG) as continuous proxies. By continuously monitoring the congruence or mismatch between cognitive intent and motor execution, the system inversely infers the user's psychological state. This diagnostic mapping directly drives the real-time, closed-loop interventions. The main contributions of this paper are summarized as follows:

  1. A multimodal, mental-physical aware exoskeleton system is developed to fuse real-time EEG and sEMG signals, enabling the continuous monitoring of the user's mental and physical engagement during robot-assisted training.

  2. A Flow-grounded fuzzy decision engine, coupled with a sensorless variable impedance controller, is proposed. By estimating the user's Flow state, the system dynamically adjusts guiding stiffness and feedforward assistance to mitigate physical passivity, address the mismatch between mental intent and physical execution, and optimize the AAN interaction.

References (30)