arXiv:2610.21703cs.CVOct 2026

Manuscript Offprint

arXiv:2610.21703

Mixture of Multi-Sequence Feature Difference for Contrast-Enhanced MRI Synthesis

Jonghun Kim, Junmo Kwon, Hyunjin Park

Jonghun Kim D◯\textcircled{D}, Junmo Kwon D◯\textcircled{D}, and Hyunjin Park ⋆\star D◯\textcircled{D}

Department of Electrical and Computer Engineering,

Sungkyunkwan University, Suwon, Korea

{iproj2, skenfn1231, hyunjinp}@skku.edu

Abstract. Contrast-enhanced magnetic resonance imaging (CE-MRI) is crucial for accurately diagnosing and segmenting brain tumors. However, the acquisition of CE-MRI requires injecting contrast agents, which poses potential health risks and increases scan costs. Here, we propose a CE-MRI synthesis method from non-contrast sequences, reducing both risk and cost. Unlike existing methods that rely on channel-wise concatenation to fuse multi-sequence information for synthesis, we introduce a Mixture of Feature Difference (MoFD) module. The proposed module uses a dynamic weighting strategy to adaptively select and aggregate informative features from both individual source sequences and explicit differences among them. Quantitative and qualitative evaluations demonstrate that our proposed method outperforms baselines in terms of image fidelity and perceptual quality on the UCSF-PDGM and UPenn-GBM datasets. Our method successfully reconstructs tumor regions and achieves segmentation performance comparable to that obtained with real CE-MRI. Our ablation studies show that although adversarial learning improves perceptual quality, a regression-based variant of our method achieves higher structural fidelity. Our code available at github.com/jongdory/MoFD.

Keywords: Contrast-Enhanced MRI Synthesis · Medical Image Translation · Mixture of Feature Difference

1 Introduction

Contrast-enhanced magnetic resonance imaging (CE-MRI) is a pivotal tool that uses a contrast agent injected into the bloodstream to enhance image clarity [9,30,31,51][9,30,31,51]. Although non-contrast MRI is sufficient for observing anatomical structures, it often lacks the sensitivity needed to identify vascular conditions and subtle tissue discrepancies. It is difficult to distinguish tumors or inflammation from healthy tissue on non-contrast scans because these conditions often have similar intensities [10][10]. CE-MRI addresses this issue by using contrast agents that make blood vessels and lesions hyperintense on T1-weighted images. This hyperintensity enables the precise identification of the location and extent of

  • Corresponding Author

J. Kim et al.

Figure

T1-weighted image

T2-weighted image

T2-FLAIR image

T1-contrast enhanced image

Fig. 1: Illustration of non-contrast multi-sequence MRI and contrast-enhanced MRI. Red bounding boxes show zoomed-in views of the tumor region. Unlike the non-contrast sequence images, the T1 contrast-enhanced image clearly delineates tumor boundaries.

these lesions [38]. As shown in Fig. 1, tumor boundaries are ambiguous in other non-contrast MRI sequences, whereas the contrast-enhanced image clearly delineates the tumor region. Despite these advantages, administering contrast agents raises safety concerns because gadolinium may not be fully excreted, potentially leading to accumulation in the brain and bones [25, 40]. Furthermore, CE-MRI requires longer acquisition times and incurs higher costs.

To address these issues, recent studies have explored generative model-based medical image translation for synthesizing CE-MRI from non-CE images [27]. In particular, Generative Adversarial Network (GAN) [17] and diffusion model [21] based generative models have been widely investigated for synthesizing target modalities by concatenating source modalities along the channel dimension as input [11, 13, 29, 48, 53]. Ea-GAN [53] is a 3D Pix2Pix [23]-based model that integrates edge information, effectively preserving structural details. MM-GAN [48] utilizes a 3D GAN framework that combines information from all available MRI sequences to simultaneously synthesize arbitrary missing sequences. Chen et al. [11] have proposed a 3D convolutional network designed using a fusion method that extracts unique information feature maps through independent encoders for each input modality and then combines them in the channel direction to synthesize CE-MRI within the regression framework. ResViT [13] has been introduced as a GAN-based generative model for multi-modal image synthesis that combines Vision Transformers [15] with the convolutional networks to leverage global context. ALDM [29] applies a 3D Latent Diffusion Model [46] incorporating switchable SPADE [42] blocks within the latent space, enabling the translation of a single source image into various target images. Recent studies [44] have suggested that, in medical image translation, fidelity is more critical than perceptual quality because generative models for restoration tasks are subject to the perception-distortion tradeoff [4]. Accordingly, regression losses can be more important than adversarial learning, which primarily aims to improve perceptual quality [44].

Most approaches concatenate multi-sequence images along the channel dimension for use as input. This often overlooks the distinct contrast characteristics of each sequence. For example, T1-weighted images depict fat as hyperintense, while water, cerebrospinal fluid (CSF), edema, and inflammation appear dark [16, 43]. T2-weighted images depict water, lesions, and fat as hyperintense, while air and blood appear hypointense [3, 43]. T2-FLAIR images also highlight lesions and fat, but water and CSF appear dark [14]. Furthermore, the contrast enhancement of pathologies such as inflammation and edema varies significantly.

across these sequences, serving as an important biomarker [12]. These abnormal regions can be explicitly modeled using difference maps between sequences, making them useful for accurate contrast-enhanced image synthesis. Therefore, to accurately synthesize contrast-enhanced regions, it is crucial to explicitly incorporate the diverse contrast variations of distinct sequences and their explicit differences rather than relying on channel-wise concatenation. Because channel-wise concatenation captures pixel-level relationships between source modalities, it can be sensitive to intensity scaling and noise. In contrast, modeling differences in a feature space can provide an enhanced contextual representation of inter-sequence contrast changes.

We propose the Mixture of Feature Difference (MoFD) module that effectively leverages the complementary information from multiple sequences for CE-MRI synthesis. Unlike conventional methods that concatenate sequences across channels, our approach uses an encoder to extract sequence-specific features from each input sequence capturing unique contrast characteristics. We further calculate the feature differences between sequences and dynamically allocate importance to sequence-specific features and their feature differences, enabling flexible and selective feature integration instead of fixed averaging. We validate our method with regression-based and GAN-based approaches to investigate the impact of adversarial training on improving perceptual quality. We also evaluate tumor segmentation performance on the synthesized images using nnU-Net [22] to assess synthesis quality in tumor regions.

References (55)