Abstract. Implicit Neural Representations (INRs) have recently gained popularity for their ability to model functions using simple and lightweight networks. These methods have also proven effective in deformable image registration. In this work, we extend INRs for deformable image registration to the domain of temporal image registration, focusing on periodic temporal image sequences. Our approach, Temporal-IDIR, optimizes a single INR to model deformations across all frames in a temporal image sequence simultaneously, allowing for self-regularization through its own deformation predictions. To achieve this, we introduce a temporal consistency loss that penalizes discrepancies between direct source-to-target transformations and those traversing intermediate frames. We evaluate our framework on the DIR-LAB dataset, using the target registration error (TRE) between annotated and moved landmarks as the metric. Here, we achieve a TRE of 1.03 mm, outperforming other INR-based registration methods. Additionally, our framework supports smooth interpolation between time frames by estimating deformations between the given input frames. 4^{4}

Keywords: Deformable Image Registration · Implicit Neural Representations · Neural Fields · Deep Learning · 4D CT.

1 Introduction

Temporal image registration is a fundamental process in image analysis that involves aligning two or more images taken at different times. In medical imaging, temporal registration is useful for analyzing short-term sequences, such as a heart beat, a respiratory cycle, or bowel movements, as well as long-term sequences to investigate disease progression through months or years. Registering the images across the temporal sequence offers the possibility to propagate landmarks and thereby follow the movement of anatomical structures over time.

4^{4} Code is publicly available at https://github.com/MMLowes/Temporal_INR.

M. Lowes et al.

Figure

Fig. 1: Registration of multiple landmarks from source frame (left) to target frame (right). For each source point x\mathbf{x} the deformation u(x)u(\mathbf{x}) is calculated to map the point to the target domain ΦS→T(x)\Phi_{S\to T}(\mathbf{x})

Standard deformable image registration (DIR) is performed pairwise by registering a source image ISI_S to a target image ITI_T. This can be achieved by applying a deformable vector field u(x)u(\mathbf{x}) to map each position in the source image x\mathbf{x} to align it with the target image (see Figure 1). Registration methods can be divided into two categories; optimization-based and learning-based methods. Traditional methods using B-splines to represent the deformation vector field [11,13,21] are examples of optimization-based methods, where the parameters of the splines are optimized individually for each registration. With convolutional neural networks, a group of learning-based registration methods appeared [1,7,8,15,19,22]. This approach offers the possibility of learning the registration on one data set and generalize to new unseen data, however using 3D CNNs on large 3D image volumes requires large amounts of memory.

Implicit Neural Representations (INRs) can be used as an optimization-based registration method by parameterizing the deformation field as a neural network [20]. In the simplest form, the source point coordinate x\mathbf{x} is passed to a simple multi layer perceptron (MLP) that estimates the deformation u(x)u(\mathbf{x}). This approach significantly lowers the memory requirements by operating on continuous points, while exploiting the neural networks ability to approximate any signal or function. Several works have expanded on the use of INRs by enforcing an inverse consistency between source-to-target and target-to-source registration [2,6,16] or applying geometric constraints [5].

The described methods are developed for pair-wise image registration. When a temporal sequence consists of more than two images, one can utilize pair-wise registration to either register the first image to all subsequent time frames (direct registration) or sequentially register each time frame to the next (sequential registration). Assuming smooth changes over the temporal sequence, the sequential registration will only require small deformations between consecutive time steps, whereas the direct registration may require increasingly larger deformations when the time difference is large. The sequential approach, however, builds up error through the time steps, causing problems in long sequences [12].

In this paper, we propose a novel method for temporal registration using INRs that combines direct and sequential registration, by simultaneously optimizing registration between all possible image pairs in a temporal image sequence. Our main contributions include extending INR-based registration with the temporal dimension, enabling tracking of landmark movement during a whole cycle of data, contrary to only the extreme phases. Furthermore, our method tracks landmarks between the input frames of the data, giving continuous landmark movement throughout the data cycle. We demonstrate the capabilities of the method on the open source DIR-LAB lung CT dataset [3], and show that the proposed method outperforms other INR-based registration methods.

References (22)