arXiv:2608.26647cs.CVAug 2026

Manuscript Offprint

arXiv:2608.26647

Tissue-Mixture Entropy-Weighted Reconstruction for Partial-Volume-Aware Brain MRI Super-Resolution

Xiao Tong, Wenyun Yang, Ziheng Zhang, Jingzhi Han, Zhaochu Luo, Jinbo Yang

Abstract

Background and Objectives: Full-image objectives in brain magnetic resonance imaging (MRI) super-resolution (SR) can under-weight tissue-transition regions affected by the partial-volume effect (PVE), as these regions occupy a small fraction of the image. Binary boundaries further provide only a discrete approximation of continuous tissue mixtures within a voxel.

Methods: We propose Anatomy-Guided Gaussian-Parameter Warping with PVE-Balanced Reconstruction (AGW-PBR), combining a low-resolution (LR)-only reconstruction backbone with a PVE-aware training objective. The backbone uses LR-derived anatomical guidance, soft latent assignment, and bounded residual warping. Quality-controlled tissue fractions are converted into tissue-mixture entropy to spatially weight reconstruction within validated PVE support. PVE sidecars are used only during training, while inference requires only the LR image. Downstream utility is further evaluated through zero-shot transfer to whole-tumor segmentation on BraTS2023.

Results: AGW-PBR improves reconstruction across 2× and 4× SR on IXI and achieves the lowest normalized gradient-vector reconstruction error at both CSF–GM and GM–WM interfaces at 4×. Ablation studies verify the contributions of PVE-aware weighting and soft latent assignment. The PVE-free AGW backbone also maintains strong performance on fastMRI. On BraTS2023, AGW-PBR achieves competitive whole-tumor Dice and the lowest HD95 under direct zero-shot transfer.

Conclusions: AGW-PBR improves brain MRI SR while preserving tissue-transition information relevant to downstream analysis. The results support tissue-mixture entropy as an effective supervision signal for partial-volume-aware MRI reconstruction.

Keywords: MRI super-resolution; Partial-volume effect; Tissue-mixture entropy; PVE-balanced reconstruction

1. Introduction

Magnetic resonance imaging (MRI) provides strong soft-tissue contrast for structural assessment and quantitative image analysis. High spatial resolution is particularly important in brain MRI for delineating cortical folds, tissue interfaces, and small anatomical structures. However acquiring images at a higher spatial resolution generally requires longer scan time and introduces trade-offs in signal-to-noise ratio, motion sensitivity, and clinical throughput [1, 2]. Image super-resolution (SR) provides a computational alternative by estimating a high-resolution (HR) image from a low-resolution (LR) observation.

*Corresponding author. Tel.: +86 10 62753459; Fax: +86 10 62751615. Email addresses: tongxiao@stu.pku.edu.cn (Xiao Tong),

yangwenyun@pku.edu.cn (Wenyun Yang), zhangziheng@magnvue.com (Ziheng Zhang), hanjingzhi@pku.edu.cn (Jingzhi Han),

zhaochu.luo@pku.edu.cn (Zhaochu Luo), jbyang@pku.edu.cn (Jinbo Yang) without modifying scanner hardware.

Brain MRI SR is particularly sensitive to tissue transitions. At finite spatial resolution, voxels near cerebrospinal fluid (CSF), gray matter (GM), and white matter (WM) interfaces can contain contributions from multiple tissues, producing partial-volume effects (PVEs) [3, 4, 5]. These regions occupy a small fraction of the image, so their reconstruction errors can receive limited aggregate influence under full-image objectives dominated by homogeneous tissue. Boundary-aware losses emphasize contours [6], while tissue fractions provide a continuous description of within-voxel composition. Existing PVE studies primarily address segmentation and tissue-fraction estimation [4, 5, 7].

We propose Anatomy-Guided Gaussian-Parameter Warping with PVE-Balanced Reconstruction (AGW-PBR), which consists of an LR-only reconstruction backbone and a PVE-balanced training objective. The reconstruction backbone uses LR-derived structural guidance, compact soft latent assignment, and bounded grid-anchored residual warping. During training, quality-controlled CSF/GM/WM pseudo-label sidecars provide tissue-mixture entropy, which defines mean-normalized spatial reconstruction weights within validated PVE support. The sidecars remain fixed training resources. Here, “Gaussian-parameter” refers to the displacement and gating parameterization of the warping module.

The contributions of this work are summarized as follows:

  • We introduce PVE-Balanced Reconstruction, which uses mean-normalized tissue-mixture entropy to increase the contribution of partial-volume tissue transitions during training while retaining full-image reconstruction supervision.

• We develop an LR-only Anatomy-Guided Gaussian-Parameter Warping (AGW) reconstruction framework based on image-derived structural guidance, compact soft latent assignment, and bounded grid-anchored residual warping.

• We establish quality-controlled PVE sidecars and independent SynthSeg-based evaluation of regional fidelity and CSF–GM/GM–WM tissue-transition gradients. Boundary-profile RMSE provides complementary analysis on HR-eligible profiles.

• We evaluate the AGW-PBR model on the IXI dataset at 2×2\times and 4×4\times with subject-level paired analysis and further assess downstream information retention through zero-shot transfer to a frozen BraTS2023 whole-tumor segmentation probe. We separately evaluate the AGW reconstruction backbone on the fastMRI dataset under an independent SR-only protocol without PVE sidecars.

References (25)