arXiv:2610.20596cs.ROOct 2026

Manuscript Offprint

arXiv:2610.20596

CoWear: Towards Collaborative Wearable Inertial Localization with Multiple Smart Devices

Zhuoyuan She, Zhanpeng Zhang, Yapeng Chen, Jiale Wang, Xin Xie, Ming Xia

Zhuoyuan She 1,∗^{1,*}, Zhanpeng Zhang 1,∗^{1,*}, Yapeng Chen 2^{2}, Jiale Wang 3^{3}, Xin Xie 4^{4}, Ming Xia 3^{3}

Abstract—Consumer smart devices observe the same human motion from different body locations, yet existing inertial-localization benchmarks rarely provide synchronized heterogeneous wearables with device-specific motion ground truth. We present CoWear, a dataset and reference framework for collaborative inertial localization using a smartphone, smartwatch, and smart glasses. The dataset contains over 30 participants, over 300 walking sessions, and more than 30 hours and 100 km of aggregate device trajectories, with each device individually tracked by motion capture. To enable collaboration across distinct body motions, we train role-specific estimators to predict the displacement of a common reference device over synchronized temporal windows. Their predictions are transformed to the world frame using gyroscope integration and fused according to learned uncertainty. Experiments using phone, glasses, and watch as reference targets show that multi-device fusion consistently improves both displacement and trajectory rollout accuracy over individual-device estimation. CoWear provides a dataset and reproducible baseline for studying collaborative inertial localization across heterogeneous consumer wearables.

I. INTRODUCTION

Consumer devices such as smartphones, smartwatches, and smart glasses increasingly accompany users throughout daily activities and continuously measure motion with embedded inertial sensors. Their independence from external infrastructure makes them attractive for pedestrian localization in indoor and GNSS-denied environments, where learning-based inertial odometry has shown strong potential with low-cost IMUs [1]-[3]. Yet most existing systems localize from one sensing device at a time, even though a user may simultaneously carry several inertial devices at different body locations. This naturally raises the question of whether these heterogeneous devices can provide redundant observations of human locomotion and jointly improve localization.

A key difficulty is that the motion of a sensing device is not necessarily the motion that localization aims to recover. A handheld phone, wrist-worn watch, and head-mounted glasses share the same global locomotion but also undergo distinct local motions caused by arm swing, head motion, and changing carrying styles. This discrepancy is already present in common inertial-localization settings where the IMU and trajectory reference correspond to different physical carriers [2], [4]. In such cases, device-specific motion is

Figure

Fig. 1. Representative device–motion mismatch in RIDI. (a) Ground-truth and NIO trajectories. (b) Motion and device headings. (c) Heading difference. The purple boxes highlight a short interval where device motion deviates sharply from the underlying locomotion.

not directly supervised and must be implicitly absorbed by the estimator. As illustrated in Fig. 1, a representative RIDI example highlights how substantial device motion can coexist with much smaller changes in the underlying human trajectory.

This observation motivates two design choices in CoWear. First, multiple wearables provide redundant but non-identical observations of the same locomotion, offering the possibility of reducing the influence of device-specific disturbances. Second, to study this redundancy explicitly, the motion of each sensing device itself must be observable. We therefore collect synchronized smartphone, smartwatch, and smartglasses inertial data while independently tracking every device with motion capture. This produces device-specific 6-DoF ground truth and allows each wearable to be analyzed either as a motion source or as a common localization reference.

The remaining challenge is how to compare and combine observations from non-co-located body locations. For every synchronized temporal window, role-specific estimators predict the displacement of one selected reference device from each wearable. These estimates are transformed into a shared world frame using gyroscope integration and combined through learned uncertainty. This common-target formulation avoids averaging trajectories of different physical carriers. Experiments with phone-, watch-, and glasses-reference targets show consistent improvements from collaborative estimation over single-device inference.

Our contributions are as follows:

∗^{*}Zhuoyuan She and Zhanpeng Zhang contributed equally to this work.

1^{1}School of Electronic and Information Engineering, Beihang University, Beijing, China.

• We introduce CoWear, a synchronized multi-device inertial dataset containing smartphone, smartwatch, and smart-glasses measurements with device-specific 6-DoF motion-capture ground truth.

2^{2}School of Automation Science and Electrical Engineering, Beihang University, Beijing, China.

3^{3}School of Space and Earth Sciences, Beihang University, Beijing, China.

4^{4}Jiangxi Research Institute, Beihang University, Nanchang, China.

  1. Multi-device Wearable Sensing

A unified platform for synchronized data collection

  1. Motion-Capture Ground Truth Collection

High-precision walking trajectories

Figure

  1. Multiple Participants

Diverse walking styles and scenarios

Figure

  1. Data Curation and Structuring From raw recordings to analysis-ready data

Figure

Fig. 2. Overview of the CoWear dataset construction pipeline. Three heterogeneous wearables are recorded simultaneously and independently tracked by motion capture. Data from multiple participants are temporally aligned, reorganized, and curated into synchronized analysis-ready sessions. Dataset scale is reported using aggregate device trajectories.

• We formulate collaborative localization across non-co-located wearables as common-reference displacement estimation from synchronized heterogeneous observations.

• We provide a reproducible collaborative localization baseline that maps heterogeneous wearable observations to a common reference displacement and combines them through uncertainty-aware fusion.