arXiv:2610.17251cs.CVOct 2026

Manuscript Offprint

arXiv:2610.17251

HybridDualPathNet: Cross-Fusion Attention of EfficientNetV2 and Swin Transformer for Brain MRI Classification of Alzheimer's and Parkinson's Disease

Jarpula Nirjala, Rahul Patel

Jarpula Nirjala

Department of Electronics and Communication Engineering

Indian Institute of Information Technology, Surat, India

Email: nirjala8462@gmail.com

Rahul Patel

Department of Electronics and Communication Engineering

Indian Institute of Information Technology, Surat, India

Email: rahulpatelanuppur@gmail.com

Abstract—Separating Alzheimer's Disease (AD), Parkinson's Disease (PD), and Healthy Controls (HC) on a single structural MRI is a genuinely awkward problem. The disease signatures overlap on the cortex, PD scans are always in short supply, and—the part most papers quietly skip—how the data is partitioned tends to decide the headline number more than the network does. We study HybridDualPathNet, which pairs EfficientNetV2-S (local texture) with Swin-Tiny (global context) and fuses them through a Cross-Fusion Attention (CFA) unit that decides, scan by scan, how much of each stream to trust, and we run it through two experiments. The first is the conventional one: train and test on the Kaggle APD-3-Class set alone under an image-level split, where the model reaches 98.25% accuracy. The second is stricter: one model trained and tested on Kaggle and ADNI together, 17,859 slices, under a per-source patient-wise split so no subject's slices land on both sides. There the same network scores 73.4% accuracy and 0.880 macro AUC, and splitting the result by source exposes the real story—91.2% on Kaggle-style scans but only 59.2% on ADNI. Temperature scaling pulls expected calibration error from 0.130 to 0.015, split-conformal prediction gives 89.5% coverage, and multi-method saliency confirms the network looks at brain tissue rather than skull. The 25-point gap between the two experiments is, honestly, the most useful result here.

Index Terms—Alzheimer's disease, Parkinson's disease, brain MRI, data leakage, patient-wise split, cross-dataset generalization, ADNI, cross-fusion attention, calibration, Grad-CAM++.

I. INTRODUCTION

Neurodegenerative disease keeps adding to the load on health systems everywhere. Alzheimer's is now diagnosed in upward of 55 million people [1], Parkinson's in roughly ten million more [2], and both totals keep rising as the population ages. A T1-weighted structural scan is usually the first thing a neurologist reaches for: it is cheap, carries no ionizing dose, and tracks morphological change well enough to be worth reading. The catch is that AD and PD leave structural marks that look a lot alike, and radiologists themselves part ways on the borderline cases [3]. An automated reader that could prescreen these scans would take real pressure off overstretched clinics, and deep networks routinely post accuracies in the high nineties on public benchmarks.

We were, frankly, suspicious of those numbers, and this paper grew out of that suspicion. Two habits in the literature quietly inflate reported accuracy. First, the image-level split: MRI contains many adjacent slices per patient, and if a random split scatters them across train and test, a model can pass simply by recognizing a brain it has already seen. Second, single-dataset evaluation, which never asks whether a model tuned to one scanner survives contact with another. So we report two experiments back to back—the ordinary Kaggle-only setup first, then a leakage-controlled two-cohort setup—using the same network for both, so the reader can see exactly how much the protocol, not the model, is worth. Three familiar technical gaps sit underneath all of this.

Gap-1 (Architecture). CNNs read fine local texture well but miss how distant regions relate; Vision Transformers capture that global context but blur local detail. No prior work on this benchmark fuses both through a mechanism that adapts the blend per scan.

Gap-2 (Data). PD is badly under-represented—only 906 slices on Kaggle, and just 967 in our combined set against thousands of AD and CN. Plain oversampling invites memorisation; undersampling throws away signal.

Gap-3 (Calibration). Accuracy and F1 are usually where the reporting stops. For screening that is not enough: the dangerous case is a network that is wrong while sounding certain, so we treat calibrated probabilities as part of what the model has to deliver.

Our contributions are as follows.

  • The CFA fusion unit, whose per-sample, per-dimension gate mixes the convolutional and transformer streams through 8-head attention in place of a static concatenation, letting the network lean on local hippocampal texture for AD-like scans and on global context for PD-like ones without any hand-set rule, at a cost of under a million extra parameters.

• A complete single-dataset (Kaggle) study—training, component ablation, a comparison against eight published methods, calibration, and Grad-CAM++ saliency— reaching 98.25% accuracy, reported first as the conventional image-level baseline that most prior work on this benchmark is measured against.

• A leakage-controlled, two-cohort study on Kaggle and ADNI together (17,859 slices), split per source and by patient so that no subject's slices cross partitions, with results reported by source so the cross-scanner domain gap is measured rather than quietly averaged away.

• A direct comparison of the two experiments showing the same network—identical weights, loss, and training recipe—drops from 98.25% to 73.4% once leakage is removed, the clearest evidence here of how much single-dataset, image-level evaluation inflates the accuracies routinely reported on this task.