arXiv:2610.17318cs.CLOct 2026

Manuscript Offprint

arXiv:2610.17318

From Sampled Evidence to Radiology Reports: Objectives, Constraints, and Realization

Kun Zhao, Haoteng Tang, Chenghua Lin, Liang Zhan

Abstract

Sampling multiple reports creates an inference problem: how should sampled evidence be converted into a final decision, and does a better structured decision yield a better report? We study these questions through a framework that separates the decision signal, scoring objective, and feasible decision set, followed by text realization. On MIMIC-CXR and IU-Xray, controlled comparisons across 13 generator configurations per benchmark under grouped development/test evaluation reveal three findings. First, changing the objective under fixed evidence and rule capacity changes predictions and their held-out metric trade-offs. Second, relaxing candidate constraints has objective-dependent effects under shared signals and frozen scores. Diagnostics connect the IU macro-oriented assertion increase to near-zero label thresholds and show that limited candidate coverage coexists with selection headroom. Third, a controlled realization study with SFT-Qwen3-VL-8B shows that decision-level gains can be attenuated, amplified, or reversed. Change decomposition reveals that realization can remove incorrect assertions while losing correct findings, so target fidelity and reference accuracy need not improve together. Finding gains also do not consistently improve reference-based report quality. These results motivate separate evaluation of decision rules, candidate constraints, and realized reports.

1 Introduction

Sampling multiple outputs from a fixed generator is a common approach to improving inference. Self-consistency aggregates agreement across sampled reasoning paths (Wang et al., 2023), while minimum Bayes risk (MBR) decoding selects outputs according to expected utility (Kumar and Byrne, 2004; Eikema and Aziz, 2022). Quality-aware decoding introduces additional selection signals (Fernandes et al., 2022), and recent analyses highlight the roles of utility bias and sample diversity (Kovacs et al., 2024; Kamigaito et al., 2025). In radiology report generation (RRG), Clinical Consensus Selection (CCS) and Set-Distance Rewards (SDR) similarly exploit clinical agreement or representation distances across sampled reports (Zhang et al., 2026; Gulluk et al., 2026). These approaches motivate a broader question: how should sampled evidence be converted into a final prediction?

A sampled pool does not uniquely determine that prediction. First, the same CheXpert finding vote rates can support different predictions when decision rules are selected for majority agreement, macro-F1, or micro-F1. F-measure optimization provides established motivation for objective-dependent decision thresholds (Lipton et al., 2014; Koyejo et al., 2014). Second, candidate selection can return only an existing report, whereas predicting findings individually can produce a label combination absent from the pool. Lexically distinct reports may express identical findings, so textual diversity need not expand the clinical combinations available to selection, consistent with the broader distinction between lexical and semantic diversity (Kuhn et al., 2023). Third, realizing a predicted finding vector as text may omit requested findings or introduce additional assertions. Prior RRG research has consequently emphasized factual completeness and consistency (Miura et al., 2021) and developed clinical evaluation methods beyond lexical overlap (Yu et al., 2023; Ostmeier et al., 2024; Zhao et al., 2024). Finding accuracy, target fidelity, and reference-based report quality therefore warrant separate evaluation.

Method-level comparisons can obscure these distinctions because inference procedures often change their signals, scoring rules, output restrictions, and realization procedures simultaneously. Recent RRG methods also improve reports through multi-objective training or retrieval-conditioned generation (Xiao et al., 2025; Park et al., 2026), making complementary changes to different components of the pipeline. A performance difference between systems therefore does not identify which component produced it. Likewise, an improvement in finding-level F1 does not establish an improvement in the final report. These considerations motivate a central inquiry: How do inference-time decision objectives, candidate constraints, and text realization jointly determine the quality of outputs produced from the same sampled evidence? We separate it into three research questions:

• RQ1: Objective choice. Given the same sampled evidence, how does choosing a different objective affect predictions and performance?

• RQ2: Candidate constraints. How does the effect of restricting predictions to finding combinations represented in the sampled pool depend on the scoring objective?

• RQ3: Text realization. How faithfully do retrieval and generation express predicted findings, and do improvements in finding predictions persist in the resulting reports?

To address these questions, we separate sampling-based inference into the decision signal, or information used for prediction; the scoring objective, which evaluates possible outputs; and the feasible decision set, which specifies permitted outputs. For finding-level predictions, text realization then converts the selected findings into a report. This framework accommodates both report selection and finding prediction, while guiding comparisons that isolate particular design choices.

We study MIMIC-CXR and IU-Xray under grouped development/test evaluation. Across 13 generator configurations per benchmark, RQ1 varies shared-threshold objectives and candidate utilities, while RQ2 compares constrained, partial, and free predictions under shared signals and frozen objective-specific scores. Partial replacement applies free predictions only to five labels with the lowest training prevalence. For RQ3, we apply the RQ2 decision rules to obtain structured finding targets, and realize these targets through retrieval or generation using a fine-tuned Qwen3-VL-8B.

Our results reveal objective-dependent effects of candidate relaxation, with diagnostics separating threshold behavior, pool coverage, and selection headroom. Realization can correct false positives while losing true positives, so fidelity and reference accuracy need not improve together. These findings motivate separate evaluation of structured decisions and final reports.

Our contributions are:

• We develop a controlled inference framework that separates decision signals, scoring objectives, feasible decision sets, and text realization, enabling component-level comparisons under fixed sampled evidence.

• Across 13 generator configurations per benchmark, we demonstrate objective-dependent effects of candidate relaxation: improving surrogate scores need not improve held-out F1, with diagnostics identifying threshold-driven assertion inflation, candidate coverage limitations, and selection headroom.

• We show that finding-level gains can be attenuated, amplified, or reversed during report realization. Reference-aware change decomposition further reveals that correcting false assertions can coincide with losing correct findings, separating target fidelity from reference accuracy and report quality.

References (32)