Generalizable field of view extension for diffusion MRI via conditional flow matching

Gaurav Rudravaram, Lianrui Zuo, Ema Topolnjak, Michael E. Kim, Adam M. Saunders, Elyssa M. McMaster, Paula Trujillo, Ely E. Wesley, Colin D. McKnight, Pratik P. Pandharipande, Mayur B. Patel, Cayce Strength, Brenda T. Pund, Amelia W Maiga, Robert S. Dittus, David A. Bennett, Julie A. Schneider, Konstantinos Arfanakis, The HABS-HD Study Team, Derek B. Archer, Timothy J. Hohman, Yelena Bodien, Daniel C. Moyer, Kurt G. Schilling, Bennett A. Landman

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Gaurav Rudravaram ∗a^{*a}, Lianrui Zuo a^{a}, Ema Topolnjak a^{a}, Michael E. Kim b^{b}, Adam M. Saunders a^{a}, Elyssa M. McMaster a^{a}, Paula Diaz Trujillo c^{c}, Ely E. Wesley d,e,f^{d,e,f}, Colin D. McKnight g^{g}, Pratik P. Pandharipande d,e^{d,e}, Mayur B. Patel h,e^{h,e}, Cayce Strength e^{e}, Brenda T. Pun d,e^{d,e}, Amelia W Maiga e,h^{e,h}, Robert S. Dittus i,f^{i,f}, David A. Bennett j^{j}, Julie A. Schneider j^{j}, Konstantinos Arfanakis j,l^{j,l}, The HABS-HD Study Team k^{k}, Derek B. Archer c^{c}, Timothy J. Hohman c^{c}, Yelena Bodien e,h^{e,h}, Daniel C. Moyer b^{b}, Kurt G. Schilling g^{g}, Bennett A. Landman a,b^{a,b}

a^{a}Dept. of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN USA; b^{b}Dept. of Computer Science, Vanderbilt University, Nashville, TN USA; c^{c}Dept. of Neurology, Vanderbilt Health, Nashville, TN USA; d^{d}Division of Allergy, Pulmonary and Critical Care, Vanderbilt Health, Nashville, TN USA; e^{e}The Critical Illness, Brain Dysfunction and Survivorship (CIBS) Center; f^{f}Tennessee Valley Veteran's Affairs Geriatric Research Education Clinical Center (GRECC), Nashville, TN; g^{g}Dept. of Radiology and Radiological Sciences, Vanderbilt Health, Nashville, TN USA; h^{h}Division of Acute Care Surgery, Vanderbilt Health, Nashville, TN, USA; i^{i}Division of General Internal Medicine and Public Health, Vanderbilt Health; j^{j}Rush University Medical Center, Chicago, IL, USA; k^{k}HABS-HD MPIs: Sid E O'Bryant, Kristine Yaffe, Arthur Toga, Robert Rissman, & Leigh Johnson; and the HABS-HD investigators: Meredith Braskie, Kevin King, James R Hall, Melissa Petersen, Raymond Palmer, Robert Barber, Yonggang Shi, Fan Zhang, Rajesh Nandy, Roderick McColl, David Mason, Bradley Christian, Nicole Joe Lee, Badri Vardarajan, Monica Rivera Mindt, Phillips, Stephanie Large, Amrita Cheema, Lisa Barnes, Mark Mapstone, Annie Cohen, Amy Kind, Ozioma Okonkwo, Raul Vintimilla, Zhengyang Zhou, Michael Donohue, Rema Raman, Matthew Borzage, Michelle Mielke, Beau Ances, Ganesh Babulal, Jorge Llibre-Guerra, Carl Hill and Rocky Vig; l^{l}Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA

ABSTRACT

Incomplete field-of-view (FOV) diffusion MRI (dMRI) acquisitions compromise whole-brain white matter analysis by excluding brain regions from tractography and connectivity studies. While deep generative models for dMRI FOV extension have been proposed, their generalizability remains limited by the acquisition-dependent nature of dMRI, where signal intensity varies with b-value, gradient direction, and scanner protocol, and the inherent 4D complexity of the data, making it difficult to train models that transfer across sites or acquisition schemes without retraining. We propose a flow-matching generative model that extends the dMRI FOV in both the superior and inferior directions by predicting apparent diffusion coefficients (ADC) in six directions, conditioned on the two nearest acquired slices and the full-FOV T1w image to enforce both local diffusion continuity and anatomical consistency. The ADC representation decouples the model from acquisition-specific b-values and gradient directions, providing a middle-ground across protocols. The model was trained on 3,103 subjects (5,105 sessions) across five different datasets spanning diverse acquisition schemes (b = 500 and 1000 s/mm²; 21–192 gradient directions), four single-shell (b = 1000) and one multi-shell (b = 500/1000). Evaluated on 299 subjects across five independent datasets spanning b = 750–1500 s/mm² and 32–90 gradient directions, with single- and multi-shell schemes unseen during training, the proposed method achieves significantly improved bundle Dice score on downstream tractography (p < 0.01). To facilitate reproducibility and adoption, we publicly release the trained model weights together with a containerized inference pipeline that performs automatic FOV extension from truncated dMRI and co-registered T1-weighted images [zenodo link will be provided for final submission].

Keywords: Diffusion MRI, flow-matching, representation learning, generative modelling

*gaurav.rudravaram@vanderbilt.edu

1. INTRODUCTION

Alterations in white matter have been reported across a wide range of neurological and psychiatric conditions, including Alzheimer's disease (AD) 1^{1}, traumatic brain injury 2,3^{2,3}, delirium 4^{4}, bipolar disorder 5^{5}, and age-related cognitive decline 6^{6}. In particular, degradations in white matter integrity have been implicated early during AD and are shown to be associated with progressive cognitive impairment 7^{7}. Although macrostructural alterations, such as regional atrophy and brain volume loss, have been extensively characterized 8^{8}, growing evidence suggests that subtle microstructural abnormalities emerge during healthy aging and the earliest stages of neurodegeneration 9^{9}. Characterizing these microstructural alterations and their trajectories across the lifespan 10^{10} is therefore essential for improving our understanding of brain aging, disease progression, and the mechanisms underlying cognitive decline.

Field of view(FOV) truncation corrupts tractography

Figure

Full FOV(reference)

Figure

Inferior FOV truncation

Figure

Superior FOV truncation

Acquisition variability in dMRI confounds generalizability

Angular resolution

Figure

12 directions

42 directions

162 directions

Radial resolution

Figure

Figure 1: Top row: White matter bundles and tracts that span the inferior and superior portions of the brain are impacted due to FOV truncation. Bundles that extend toward the top and bottom of the brain are the most affected. In the full-FOV subject (left), the corticospinal tract (CST) fans out toward the cortex superiorly and reaches the brainstem inferiorly. Under inferior truncation (middle), the CST is cut off before reaching the spine and under superior truncation (right), it fans out less and does not extend to the top of the brain. Missing segments like these can propagate into downstream tract-based and connectivity analyses. Bottom row: Representational deep learning for dMRI is complicated by differing acquisitions differ in angular resolution (shown as icosahedral tessellations) and radial resolution (the number and value of sampled b-value shells.

Diffusion magnetic resonance imaging (dMRI) enables non-invasive characterization of white matter microstructure by sensitizing the MR signal to the microscopic displacement of water molecules inside tissue 11^{11}. The diffusion weighting is achieved by applying paired diffusion-sensitizing gradients, causing the measured signal attenuation to depend on the self-diffusion of water molecules 12^{12}. The degree of diffusion weighting is determined by the b-value, which depends on the strength, duration, and timing of the applied gradients 13^{13}. In white matter, water diffusion is anisotropic due to the restrictive effects of axonal membranes and myelin, resulting in signal attenuation that depends on the orientation of the applied diffusion gradient relative to the underlying fiber architecture 14^{14}. Repeating these measurements along many directions probes the orientational structure of white matter, and the diffusion signal in each voxel is naturally described on a solid sphere, with a radial component set by the strength of the diffusion weighting and an angular component set by the direction along which it is applied 15,16^{15,16}. This orientational information estimated at each voxel can then be propagated throughout the brain using tractography to reconstruct white matter pathways enabling automated segmentation and analysis of anatomically defined fiber bundles with publicly available methods such as TractSeg 17^{17}, BundleParc 18^{18} and BrainstemSeg 19^{19}.

However, adequate angular and radial sampling requires acquiring multiple diffusion-weighted volumes, so dMRI acquisition times exceed those of a structural T1-weighted (T1w) scans 20^{20}. To remain feasible, diffusion protocols generally adopt coarser spatial resolution and a more restricted field-of-view (FOV) compared to the accompanying T1w scans. The reduced coverage leaves little margin for error in slab placement, and variability in positioning, head size, or subject motion truncates the FOV at the superior or inferior extent of the brain, most often affecting the vertex and cerebellum 21^{21}. Truncation removes the diffusion information required to reconstruct any streamline passing through the affected region, causing bundles that traverse those areas to terminate prematurely or be missed entirely during segmentation (Figure 1). Bundle-wise measures are then computed over incomplete pathways, introducing systematic bias and, in longitudinal or multi-site studies, variability unrelated to the biology of interest. Recovering the missing diffusion signal is essential for preserving tractography and unbiased bundle-wise microstructural analyses, motivating learning-based approaches for FOV extension.

Deep generative models provide a promising route to recovering the missing diffusion signal. Unlike conventional anatomical images, however, diffusion MRI presents a unique representational challenge because acquisition protocols vary substantially across studies. Since the signal is jointly defined by its radial sampling (b-values) and angular sampling (gradient directions), measurements from different protocols differ in dimensionality, in the directions sampled, and in absolute scale. This protocol dependence has motivated acquisition-invariant representations of the diffusion signal. Golkov et al 22^{22}, mapped raw q-space measurements to microstructural parameters, but the mapping remains tied to the sampling scheme it was trained on. Spherical harmonic expansions provide a continuous, fixed-length alternative and have been applied to cross-scanner harmonization 23^{23} and FOD estimation 24^{24}, though high-order expansions require dense angular sampling to be well-conditioned. Nath et al. 25^{25} used a SHORE basis to obtain multi-shell b-value generalizability. Yao et al. 26^{26} convert the measured signal to apparent diffusion coefficients and resample onto the vertices of an icosahedral tessellation by inverse-distance interpolation, showing that a single model can then operate across datasets with differing gradient schemes. Collectively, these studies demonstrate that suitable signal representations can substantially reduce dependence on acquisition-specific sampling schemes.

Despite these advances in protocol-invariant signal representations, existing learning-based FOV extension methods for dMRI remain largely acquisition-specific. Chen et al. 27^{27} parcellate tractography under incomplete FOV by augmenting training with synthetically truncated tractograms, allowing streamlines to be correctly labeled despite missing regions. The missing signal is never recovered, so the approach must be re-engineered for each downstream analysis and cannot restore microstructural measures in the affected territory. Gao et al. 21^{21} synthesize missing diffusion-weighted volumes with a conditional pix2pix framework, mapping each volume independently using a co-registered T1w image as anatomical reference and Li et al. 28^{28} extend this with a conditional variational U-Net that additionally conditions on the gradient table. Both are trained at a single diffusion weighting and require retraining for acquisitions with different radial sampling. As a result, existing approaches cannot be readily applied to the heterogeneous acquisition protocols commonly encountered in multi-site studies and clinical practice.

In this work we propose a conditional flow matching model for dMRI FOV extension that is designed to generalize across acquisition protocols. We introduce a protocol-independent six-channel ADC representation obtained by fitting the diffusion tensor to the full acquisition and evaluating it along six canonical icosahedral directions, mapping any acquisition, at any b-value or gradient scheme, onto a common target of fixed dimensionality that is invertible back to the tensor. We then formulate FOV extension as conditional rectified flow, conditioning on the two nearest acquired ADC slices to enforce diffusion continuity and on the co-registered full-FOV T1w slice to supply the anatomy of the target region and extend autoregressively in either the superior or inferior direction without an explicit direction encoding.

References (36)