arXiv:2610.17573cs.CVOct 2026

Manuscript Offprint

arXiv:2610.17573

Benchmarking Self-Supervised 3D Medical Vision Foundation Models and Transferability Estimation

Jiaqi Tang, Yu Wang, Yang Liu, Jing Tao, Fandong Zhang, Zhou Zhen, Xiahai Zhuang, Qingchao Chen, Yining Yang, Yizhou Yu

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Self-supervised pretraining has expanded the pool of 3D medical foundation models, but published evaluations use different datasets, endpoints and fine-tuning protocols. Models also differ in architecture, pretraining objective and data, while downstream targets range from voxel-level masks to patient-level diagnoses and outcomes. As a result, published findings provide little directly comparable evidence for choosing a model for a new task. Direct comparison of adaptation performance requires fine-tuning candidates on labelled target data, at substantial computational cost. We benchmark 23 candidates across the same 14 segmentation, classification and regression tasks spanning multiple anatomies and modalities. No candidate ranked among the top three across all segmentation tasks or across all classification and regression tasks; a convolutional encoder could outperform a transformer trained with the same objective on one task but underperform it on another. We benchmark transferability estimators against the fine-tuned rankings and find that their agreement varies across dense segmentation, classification and regression. InsightRank uses task-appropriate frozen-feature statistics and architecture-aware pairwise comparisons to rank candidates before fine-tuning. Across the 23-model pool, mean Kendall τ\tau-b was 0.431 for segmentation and 0.352 for classification and regression. The segmentation Top 3 contained a task winner on four of nine tasks; the image-level Top 3 contained none on the five tasks, despite better full-ranking agreement than the matched conventional estimators. A three-model shortlist reduced recorded extraction-plus-training job time by 85.8% across seven segmentation tasks, excluding untimed statistic computation. Together, the benchmark provides a common reference for model selection and InsightRank offers a lower-cost way to prioritize fine-tuning, with shortlist performance that differs by target type.

Keywords: transferability estimation, foundation models, medical imaging, model selection, segmentation, classification, regression

1 Introduction

Self-supervised learning offers a way to develop 3D medical imaging models without requiring expert annotations for every pretraining scan. Such annotations are costly to obtain, particularly for volumetric segmentation, whereas unlabelled scans can support representation learning at a larger scale. By deriving training signals from the images themselves, self-supervised pretraining can learn reusable anatomical and imaging features, reduce reliance on task-specific labels and provide an initialization for downstream adaptation [1–4]. These advantages have motivated the development of a growing range of foundation models, with different architectures, learning objectives and pretraining collections [5–10]. Their increasing availability creates an important practical question: which pretrained model should be used for a particular medical imaging task?

No single foundation model is consistently best across downstream tasks. Delin-eating a small lesion, segmenting an organ and predicting a diagnosis or continuous outcome require different aspects of an image representation, so an advantage on one target need not extend to another. Existing evaluation practices make these differ-ences difficult to assess: models are commonly evaluated on different task collections, with different data partitions, preprocessing, fine-tuning settings and comparison baselines [5, 10]. A state-of-the-art result therefore establishes an advantage within the reported setting, but does not establish superiority over models evaluated elsewhere or identify the best model for a new task. Without aligned comparisons, the effects of pretraining are also difficult to distinguish from those of downstream training and evaluation. A broad benchmark with common downstream tasks and clearly specified adaptation protocols is consequently needed to determine which model advantages recur across tasks and to provide a more informative basis for model selection.

Transferability estimation addresses the cost of making a model choice when downstream performance is not yet known. Direct comparison requires fine-tuning each candidate on the target task; repeating this across a large pool can consume substantial training resources. Transferability estimators instead use pretrained outputs or frozen features, often together with target labels, to predict the relative performance expected after adaptation. Established methods summarize source–target label relationships, evidence for simple readouts, class separation or feature information [11–18]. Segmentation-specific methods such as CC-FV additionally assess feature consistency across cases [19]. Their performance depends on the candidate models, target tasks and evaluation setting [20, 21], motivating a comparison against the same fine-tuned references used to benchmark the foundation models themselves.

The structure of 3D medical tasks creates distinct requirements for transferability estimation. For segmentation, a global feature summary may miss the local distinctions needed to delineate small structures, and abundant background voxels can dominate an unbalanced sample. Spatial and boundary sampling can retain relevant local evidence while limiting computation [22]. For classification and regression, the score must instead assess variation between patients and its relation to the outcome; categorical adaptations of continuous labels can discard outcome ordering. Encoder differences in feature dimension, normalization and spatial resolution also affect the quantities being compared, while covariance estimates can be unstable with limited target samples [23]. These considerations motivate statistics selected for the prediction target and the model comparison. Their value must then be judged both by agreement with the full ranking and by the performance retained among the few models selected for fine-tuning: improved overall ordering does not necessarily improve the top-ranked choices.

Here we establish a benchmark of 23 candidates, comprising 21 pretrained encoders and two scratch controls, across 14 segmentation, classification and regression tasks spanning several anatomies and MRI and CT inputs. Three-fold downstream outcomes provide a common reference for comparisons of architecture, self-supervised objective, data selection and externally pretrained weights under the specified adaptation protocols. No candidate ranks among the top three on every task. Matched comparisons use OpenMind, a large collection of 3D head-and-neck images for self-supervised pretraining, as a common data source [10]. They contrast ResEncL, a large residual-encoder U-Net representing 3D convolutional neural networks (CNNs), with Primus-M, a medium-sized 3D vision transformer [24, 25]. ResEncL shows a broad performance advantage in these comparisons, while masked-image-pretrained Primus-M models perform better on segmentation than their counterparts trained with other objectives. Pretraining-data selection also changes which downstream tasks benefit most. The benchmark therefore provides evidence for both model development and task-specific model choice.

We also benchmark established transferability estimators and introduce InsightRank, which combines target-appropriate frozen-feature statistics through architecture-aware pairwise comparisons. Segmentation uses local voxel evidence, whereas classification and regression use patient-feature variation and neighbour-outcome agreement. Evaluation covers full-ranking agreement, three-model shortlist performance and recorded computational cost. InsightRank retains strong segmentation models with low shortlist regret and reduces recorded extraction-plus-training time in the measured segmentation workflow. For classification and regression, it improves mean ranking agreement over the matched conventional estimators but does not recover a task winner in the three-model shortlists. Together, these analyses establish a common basis for comparing foundation models and for assessing how well transferability estimation supports a limited fine-tuning budget.

References (43)